Multisided Top/Rear Vent
Convertible Direct Vent
Fireplaces: 360DVS2
360DVS3
360DVSL
360DVSR
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
IMPORTANT: Read all instructions
and warnings carefully before
starting installation. Failure to follow
these instructions may result in a
possible fire hazard, and will void the
warranty.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion ma
Résumé du contenu de la page N° 2
360 DVS Series Direct Vent Fireplaces Table of Contents Thank you, and Congratulations on your purchase of a CFM Corporation Fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty. Installation and Operating Instructions .................................................
Résumé du contenu de la page N° 3
360DVS Series Direct Vent Fireplaces Installation & Operating Instructions This gas appliance should be installed by a qualified installer, 11. When the fireplace is installed directly on carpeting, vinyl preferably NFI or WETT (Canada) certified, in accordance tile, or any combustible material other than wood, it must be with local building codes and current CSA-B149.1 Installation installed on a metal or wood panel extending the full width Codes for Gas Burning Appliances and Equipment. If
Résumé du contenu de la page N° 4
360 DVS Series Direct Vent Fireplaces Requirements for the Commonwealth of Inspection The state or local gas inspector of the side wall Massachusetts horizontally vented gas fueled equipment shall not All gas fitting and installation of this heater shall only be approve the installation unless, upon inspection, the done by a licensed gas fitter or licensed plumber. inspector observes carbon monoxide detectors and For all side wall horizontally vented gas fueled signage installed in accordanc
Résumé du contenu de la page N° 5
360DVS Series Direct Vent Fireplaces Fireplace Dimensions - 360DVS2 J J I Rear Vent Configuration K H H K B E A E D A G Electrical Electrical Access Access Gas Line Gas Line J J Access Access J J F K C K J 6326 J 360DVS2 Top Vent Configuration rear vent K specs H H K B G C I E A E D A Electrical Electrical Access Access Gas Line Gas Line J J Access Access J F J K K Fig. 1a Fireplace specifications—360DVS2 6326 360DVS2 Appliance Dimensions top vent specs Ref. Rear Ven
Résumé du contenu de la page N° 6
360 DVS Series Direct Vent Fireplaces Fireplace Dimensions - 360DVS3 / 306DVSL / 360DVSR J K I Rear Vent Configuration H H K B ROD A E D G Electrical Access Gas Line J Access J F C K C B J K I 6326 Top Vent Configuration 360DVS3 rear vent H specs H K B G A E D Electrical Access J Gas Line Access J F C K B 6326 Fig. 1b Fireplace specifications—360DVS3/ 360DDVSL/ 360DVSR 360DVS3 top vent Appliance Dimensions specs Ref. Rear Vent Configuration Top Vent Configuration A 38 ¹⁄₈” (
Résumé du contenu de la page N° 7
360DVS Series Direct Vent Fireplaces Framing Dimensions - 360DVS2 ROD Rear Vent Configuration ROH CFM121 ROW ROD Top Vent CFM121 Configuration 360DVS2 REAR VENT CONFIGURATION 8/10/00 ROH ROW CFM122 Fig. 2a Fireplace framing dimensions—360DVS2 CFM122 360DVS2 - TOP VENT CONFIGURATION Framing Dimensions 8/10/00 Ref. Rear Vent Configuration Top Vent Configuration ROD 24” (610 mm) minus two times finishing material thickness to be even with face of unit. ROH 38 ⁵⁄₈” (981 mm) Not to be framed un
Résumé du contenu de la page N° 8
360 DVS Series Direct Vent Fireplaces Framing Dimensions - 360DVS3 / 360DVSL / 360DVSR Rear Vent Confiration ROD ROW ROD ROD ROH ROH ROH 360DVSL 360DVS3 360DVSR CFM123 360DVS/3/L/R Top Vent Configuration CFM123_360DVS3_dims_RV2 REAR VENT CONFIGURATION 8/10/00 rev. 8-23-02 rjs ROD ROD ROD ROW ROH ROH ROH 360DVSL 360DVS/3/L/R 360DVS3 360DVSR CFM124 Fig. 2b Fireplace framing dimensions—360DVS3/ 360DVSL/ 360DVSR CFM124_360DVS3_TV2 TOP VENT CONFIGURATION 8/10/00 Framing Dimensions rev. 8-23-02
Résumé du contenu de la page N° 9
360DVS Series Direct Vent Fireplaces V Locating Your Fireplace W X Y X Z X X B Y A A B C D E Y A Fireplace Z Y Louvre Assembly Top LU584-2 Fig. 3 Locating your gas fireplace LU584-2 Top of Combustion A Wall Location (Fig. 3) Chamber 360DVS Y (Minimum distance between a glass panel and a locate fireplace Bottom of Door Trim CFM146 parallel wall) = 3’ (914mm) Z (Minimum distance between edge of a glass panel Mantel Chart and an adjacent wall) = 3” (76mm) CFM146 Mantel Shelf Man
Résumé du contenu de la page N° 10
360 DVS Series Direct Vent Fireplaces Hearth Gas Specifications A hearth is not mandatory; however, for aesthetic Max. Min. Input Input purposes, we recommend installing a noncombustible Model Fuel Gas Control BTU/h BTU/h hearth that projects out 12” (305mm) or more from the 360DVS2RN Nat Millivolt 38,000 26,600 front of the fireplace. 360DVS2RP Prop Millivolt 38,000 28,500 Cold climate installation recommendation: 360DVS2EN Nat 24V Hi/Lo 38,000 26,600 360DVS2EP Prop 24V Hi/L
Résumé du contenu de la page N° 11
360DVS Series Direct Vent Fireplaces 7. Refit the socket assembly back into the electrical 1/2” Gas Supply box and replace the cover plate. 1/2” NPT X 1/2” Flare Shut-Off Valve 8. The EB-1 electrical junction box is now ready to sup- 3/8” Flex Line ply power to the FK12 or FK24 fan kit, if used. (From Valve) FP297a Fig. 5 Gas shutoff valve and flex connector. Electrical When using copper or flex connector, use only ap- Inlet Hole proved fittings. Always provide a union when using FP297A blac
Résumé du contenu de la page N° 12
360 DVS Series Direct Vent Fireplaces Remove These Screws Remove These Screws FP1430 Fig. 8 Alternate switch location. Optional Top Vent Application Outer Collar Adapter This appliance is shipped as a rear vent unit. If the FP1431 installation layout requires the unit to be a top vent con- Fig. 9 Remove screws from outer collar adapter. figuration, the appliance can be converted by following FP1431 the steps below. Insulation Pad top vent (Must be removed) When removing and refitting the pla
Résumé du contenu de la page N° 13
LO 360DVS Series Direct Vent Fireplaces Electronic Gas Control Valve This appliance may be fitted with a Honeywell ignition module. Installation of the remote ON/OFF starter switch on electronic ignition units (Fig. 12): 1. Thread the wiring through the holes on the side PILOT panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a HONEYWELL IGNITION MODULE conveniently located receptacle box. 24V MV MV/VP PV GRD
Résumé du contenu de la page N° 14
V Operable 360 DVS Series Direct Vent Fireplaces General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E L C B ����� B V B V ������ V Fixed Operable Closed F V B M V B J X B I V K X A CFM145a AREA WHERE TERMINAL IS NOT PERMITTED V VENT TERMINATION X AIR SUPPLY INLET 1 2 Canadian Installations US Installations CFM145a A = Clearance above grade, veranda, porch, 12” (30cm) 12” (30cm) DV Termin Location deck, or balcony 5/01/01 Rev. 12/05/01 sta B = Clearance
Résumé du contenu de la page N° 15
360DVS Series Direct Vent Fireplaces Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner D C C F = Combustible G = 6" (152 mm) Combustible V G 6" (152 mm) Noncombustible V E 2" (51 mm) Noncombustible O V F 2" (51 mm) Balcony - Balcony - with no side wall with perpendicular side wall E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4
Résumé du contenu de la page N° 16
Vertical dimension from floor of the unit to center of the horizontal vent pipe 360 DVS Series Direct Vent Fireplaces How to Use the Vent Graph Rear Wall Application The vent chart should be read in conjunction with the When installed as a rear vent unit this appliance may be following vent installation instructions to determine the vented directly to a termination located on the rear wall relationship of the vertical and horizontal dimensions of behind the appliance. the vent system. • Spe
Résumé du contenu de la page N° 17
360DVS Series Direct Vent Fireplaces STEP 5 Vent Opening for Combustible Wall Guide vent through the vent hole as you place the appli- 9 ³⁄₈” (240mm) ance in its installed position. Guide the 4” (102 mm) and 7” (178 mm) collars of the vent termina- tion into the outer ends of the venting. 10 ³⁄₈” Do not force the termination. If the vent pipes do not (265mm) align with the termination, remove and realign the vent- ing at the appliance flue collars. Attach the termination to the wall as outli
Résumé du contenu de la page N° 18
360 DVS Series Direct Vent Fireplaces Horizontal plane means no vertical rise exists on this • The maximum number of 45° elbows permitted per portion of the vent assembly. side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run. • The maximum number of 90˚ elbows per side wall • For each 45° elbow installed in the horizontal run, installation is three (3). the length of the horizontal run MUST be reduced by • If a 90˚ elbow is fitted direc
Résumé du contenu de la page N° 19
360DVS Series Direct Vent Fireplaces STEP 4 Vent Opening for Combustible Wall Apply a bead of silicone to the inner and outer flue 9 ³⁄₈” (240mm) collars of the fireplace and using appropriate length of pipe section(s) attach to fireplace with three (3) screws. Follow with the installation of the inner and outer elbow, again secure joints as described in “Connecting Vent 9 ³⁄₈” (240mm) Pipes” section. STEP 5 Measure the horizontal length requirement including a Framing Detail 2” (51 mm) overl
Résumé du contenu de la page N° 20
360 DVS Series Direct Vent Fireplaces 2” (51 mm). Secure termination to the wall with screws Zero Clearance provided, and caulk around the wall plate to weather- Sleeve (if required) 7TDVSNORK proof. (Snorkel) Firestop One alternative to screwing the termination directly to Screws Min. 4” (102mm) 7” Pipe the wallis the use of expanding plugs or an approved Clearance (Ground) exterior construction adhesive. Or, you may attach the termination with screws through Window Well the inner body