Owner’s Manual
Installation and Operation
TIARA I-B
TIARA II-B
Portland
Tested and
O O-T -T L
Listed by Oregon USA
DIRECT VENT ROOM HEATER
US
C
OMNI-Test Laboratories, Inc.
Models:
TIARAI-BK-B TIARAII-BK-B
TIARAI-BR-B TIARAII-BR-B
TIARAI-CTO TIARAII-CTO
TIARAI-CES TIARAII-CES
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating and • Read, understand and
• Leave this manual with
maintenance instructions follow these instructions party responsible for use
for safe install
Résumé du contenu de la page N° 2
Read this manual before installing or operating this appliance. Please retain this owner's manual for future reference. Congratulations This Owner's Manual should be retained for future reference. Congratulations on selecting a Heat & Glo gas appliance - We suggest that you keep it with your other important an elegant and clean alternative to wood burning appliances. documents and product manuals. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, r
Résumé du contenu de la page N° 3
- TABLE OF CONTENTS - Section 8: Appliance Setup Section 1: Listing and Code Approvals A. Remove Shipping Materials ................30 A. Appliance Certifi cations ......................4 B. Top to Rear Conversion ......................30 B. Glass Specifi cations ............................4 C. Damper Adjustment ............................31 C. Specifi cations ......................................4 D. Shutter Adjustment .............................32 D. High Altitude Installations .....
Résumé du contenu de la page N° 4
Listing and Code Approvals 1 C. Specifi cations A. Appliance Certifi cation Maximum Minimum Orifi ce *Steady **P.4 Model Input Input Size State % (US or Canada) BTU BTU Effi ciency MODEL Tiara I B % LABORATORY OMNI-Test Laboratories, Inc. Tiara I B 31,000 22,000 .106 81.43 57.33 061-S-43b-5 (NG) TYPE Vented Gas Fireplace Heater Tiara I B 30,000 23,000 .063 82.75 56.39 (LP) STANDARD ANSI Z21.88-2002 ּ CSA 2.33-2002 Maximum Minimum Orifi ce *Steady **P.4 UL307b ּ CAN/CBA 2.17-M91 Model Input Inp
Résumé du contenu de la page N° 5
Inspection NOTE: The following requirements reference various The state or local gas inspector of the side wall horizontally Massachusetts and national codes not contained in this vented gas fueled equipment shall not approve the installa- document. tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with G. Requirements for the Commonwealth of the provisions of 248 CMR 5.08(2)(a) 1 through 4. Massachusetts Exemption
Résumé du contenu de la page N° 6
Getting Started 2 C. Inspect Appliance & Components A. Design & Installation Considerations Heat & Glo direct vent gas appliances are designed to oper- ate with all combustion air drawn from outside of the building WARNING and all exhaust gases expelled to the outside. No additional air source is required. Inspect appliance and components for damage. Damaged parts may impair safe operation. CAUTION • Do NOT install damaged components. • Do NOT install incomplete components. Check building c
Résumé du contenu de la page N° 7
Appliance Location and Clearances 3 NOTE: WARNING · Illustrations refl ect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: · Illustrations/diagrams are not drawn to scale. • Around air openings · Actual installation may vary due to individual design • To combustibles • For service access preference. Locate appliance away from traffi c areas. A. Selecting Appliance Location When selecting a location for your appliance it is important to WAR
Résumé du contenu de la page N° 8
C. Clearances to Combustibles - Tiara II-B F C B C E A A "A" measurement is from appliance top, not side H G G A A D 90˚ off top up and out ceiling H Top of Side of Inside Model A B C D E F G pipe pipe Outside corner wall vent Inches Tiara II B 5-1/4 1/4 3/8 54 36 40 31-3/4 1-1/2 1 9 Millimeters 133 6 9.5 1372 914 1016 806 38 25 229 Figure 3.1 For both the Tiara I-B and Tiara II-B, it is permissible to place the appliance on carpet. WARNING Fire Risk. CAUTION Odor Risk. Tip
Résumé du contenu de la page N° 9
Termination Locations 4 A. Vent Termination Minimum Clearances HORIZONTAL OVERHANG WARNING 2 FT. 20 INCHES MIN. VERTICAL MIN. Fire Risk. WALL LOWEST Explosion Risk. DISCHARGE OPENING Maintain vent clearance to combustibles GAS DIRECT VENT as specifi ed. TERMINATION CAP • Do not pack air space with insulation or X other materials. 12 Failure to keep insulation or other materials away from vent pipe may cause fi re. ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE O
Résumé du contenu de la page N° 10
M N P G R v A H D Q (See Note 2) E v V B L U.S. B T v (3 FT) v B B v S S Electrical V V Service F v v M I D* v X A J or K V = VENT TERMINAL X = AIR SUPP L Y INLET = ARE A WHERE TERMINA L IS NOT PERMITTED V K = 3 ft. (U.S.A. ) A = 12 inche s ............. clearances above grade , veran- 6 f t. (Canada ) ......... clearance to a mechanical (S ee Not e 1 ) da, porch, deck or balcon y (powered) a i r s uppl y inle t B = 12 inche s ............ clearances to
Résumé du contenu de la page N° 11
Vent Information 5 A. Venting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only following venting components: CAUTION • Hearth & Home Technologies (HHT) ALL vent confi guration specifi cations MUST be followed. • Simpson Dura-Vent • This product is tested and listed to these specifi cations. • Selkirk Direct-Temp • Appliance performance will suffer if specifi cations are • Amerivent Direct not followed. • Security Secure Vent Diagonal
Résumé du contenu de la page N° 12
D. How to Use the Vent Graph E. Venting Guidelines NOTE: IF YOUR INSTALLATION FALLS WITHIN A SHADED AREA ON • The maximum horizontal vent run is 20 ft. (6m) when the THE GRAPH, THE DAMPER MUST BE USED.* SEE INFORMATION ON vertical vent rise is 10 ft. (3m). DAMPER ADJUSTMENT ON PAGE 31. *In the Commonwealth of Massachusetts, the word damper shall be replaced • The minimum horizontal vent run is 6 in. (152mm). with the words flue restrictor. • Horizontal sections require a 1/4 in. (6mm) rise
Résumé du contenu de la page N° 13
F. Horizontal Termination WARNING Fire Hazard. Exhaust Fume Risk. Type A - Up & Out Installation Impaired Performance of Appliance. 90° ELBOW • Ensure vent components are locked together correctly. CENTER LINE • Pipe may separate if not properly joined. TERMINATION CAP PIPE LENGTH WALL THIMBLE/ HEAT SHIELD Step 2. WALL THIMBLE COVER PIPE LENGTH Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a twist-lock ada
Résumé du contenu de la page N° 14
Step 3. For installations using a round support box/wall thimble (check pipe manufacturer's instructions), mark the wall for a WOOD SCREW 10 in. x 10 in. (254mm x 254mm) square hole. The center of the square hole should line up with the center line of the horizontal pipe, as shown in Figure 5.5. Cut and frame the hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, i.e. masonry block or concrete, a 7 in.
Résumé du contenu de la page N° 15
VINYL SIDING WARNING Apply sealant to all four sides Fire Hazard. Exhaust Fume Risk. SCREWS Impaired Performance of Appliance. • Ensure vent components are locked together correctly. Bolt horizontal top to vinyl • Pipe may separate if not properly joined. standoff SCREWS WALL THIMBLE COVER WARNING Vinyl siding standoff with siding beneath removed WALL THIMBLE Do NOT connect a pipe section to a termination cap without Figure 5.8 using the telescoping fl ue section found on the termination cap.
Résumé du contenu de la page N° 16
G. Vertical Termination 1. Direct Vent Pipe VERTICAL TERMINATION CAP STORM COLLAR 35 ft. (11m) MAXIMUM FLASHING FIRESTOP SUPPORT BOX PIPE LENGTH Figure 5.11 Step 2. Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, Figure 5.10
Résumé du contenu de la page N° 17
Step 3. To install the round support box/wall thimble cover in a flat CAP AND STORM ceiling, cut a 10 in. (254mm) square hole in the ceiling, Shingles overlap on COLLAR NOT SHOWN top edge of flashing centered on the hole drilled in Step 2. Frame the hole as FOR CLARITY shown in Figure 5.13. Ceiling Joists Framing Figure 5.14 Step 7. Continue to assemble pipe sections until the height of the vent (before adding the termination cap) meets the minimum 1 - 1/2 in. (38mm) Long Figure 5.13
Résumé du contenu de la page N° 18
Step 9. Twist-lock the vent cap and seal. Note: For multi-story vertical installations, a ceiling firestop is required at the second floor, and any subsequent floors (Figure 5.16). The opening should be framed to 10 in. x 10 in. (254mm x 254mm) inside dimensions, in the same manner as shown in Figure 5.13, on the previous page. Nails Ceiling Firestop Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Figure 5.16 WA
Résumé du contenu de la page N° 19
2. Cathedral Ceiling Step 1. Follow installation Steps 1 and 2 under vertical installation section, page 16. Step 2. Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Cut the hole 1/8 in. (3mm) larger than the support box outline. Step 3. Lower the support box through the hole in the roof until the bottom of the support box protrudes at least 2 in. (51mm) below the ceiling (Figure 5.17). Align the support box both vertically and horizontal
Résumé du contenu de la page N° 20
Step 4. 3. Class A Metal Chimney Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3mm) diameter holes through the top adapter, and into the chimney top. Ensure that you are TERMINATION CAP drilling into the metal on the chimney. Twist lock the high TOP wind termination cap onto the top adapter (Figures 5.22 ADAPTOR and 5.23). FLASHING EXISTING METAL CHIMNEY SYSTEM 4 in. (102mm) FLEX PIP