Résumé du contenu de la page N° 1
ULTRA FLAME
DIRECT VENT "0" CLEARANCE GAS FIREPLACE
INSTALLATION AND OPERATING INSTRUCTIONS
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO
THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT
A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
Résumé du contenu de la page N° 2
ULTRA FLAME DV “0” Clearance Fireplace TABLE OF CONTENTS GENERAL INFORMATION................................................................................................. 3 WARNING ............................................................................................................................... 4 SPECIFICATIONS..................................................................................................................5 OPERATION ......................................
Résumé du contenu de la page N° 3
ULTRA FLAME DV “0” Clearance Fireplace GENERAL INFORMATION The ULTRA FLAME DIRECT VENT GAS FIREPLACE is a high-efficiency free-standing gas appliance with a maximum input rating of 30 000 Btu/h with natural gas or 26,000 Btu/h with propane. It features a thermostatic modulating valve and a constant pilot. This means that you can set the height of the flame to your liking by turning the adjusting knob. An optional thermostat is also available for automatic room temperature control. T
Résumé du contenu de la page N° 4
ULTRA FLAME DV “0” Clearance Fireplace WARNING INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THIS APPLIANCE. HOT WHEN IN OPERATION. KEEP CHILDREN, FURNITURE, CLOTHING AND FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE. ADVISE ADULTS AND CHILDREN ABOUT THE HAZARD OF HIGH SURFACE TEMPERATURES AND THAT THEY SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS
Résumé du contenu de la page N° 5
ULTRA FLAME DV “0” Clearance Fireplace SPECIFICATIONS Dimensions: height 39", width 36", depth 20" o Glass: 29-1/8" x 17-3/4" 1400 F clear ceramic Minimum opening in wall for installing the units: height: 39-1/2" width: 36-1/2" Fuel: Natural Gas Propane Input : 30,000/ 20,000 26,000/20,000 Btu/h Manifold pressure : 3.5/1.8 10.5/7.0 in w.c. Min. inlet pressure : 5 11 in w.c. Max. inlet pressure :
Résumé du contenu de la page N° 6
ULTRA FLAME DV “0” Clearance Fireplace OPERATION BEFORE LIGHTING 1) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 2) Make sure that there are no obstructions in the air intake or venting system. 3) Clear the immediate area of combustible materials, gasoline, and other flammable liquids and vapour
Résumé du contenu de la page N° 7
ULTRA FLAME DV “0” Clearance Fireplace • Press gas control knob in and hold. Immediately push the red igniter button repeatedly until pilot flame ignites. Continue holding in the control knob for 5 to 10 seconds, then release it. If the pilot flame goes out, repeat this step. • Push and turn gas control knob counterclockwise to the "on" position. CAUTION: This fireplace is hot while in operation. Do not touch. Keep children, clothing and flammable materials away. WALL
Résumé du contenu de la page N° 8
ULTRA FLAME DV “0” Clearance Fireplace MAINTENANCE INSTRUCTIONS TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. The venting system and the gas fireplace should be inspected at least once a year. Remove the glass front and the logs and clean them if necessary. The control compartment, air circulating passages, firebox, logs and burner should be cleaned at least once a year by vacuuming or brushing. Check the pilot fla
Résumé du contenu de la page N° 9
ULTRA FLAME DV “0” Clearance Fireplace BURST DISC REPLACEMENT If the burst disc under the burner moves from its location, it must be put back in place into the silicone seal. Make sure the switch is depressed all the way during the installation. Otherwise the appliance will not operate. WARNING: Never glue or lubricate the disc to the silicone seal. Do not put any object under the disc. 9
Résumé du contenu de la page N° 10
ULTRA FLAME DV “0” Clearance Fireplace TOP, FRONT AND SIDE VIEWS FRONT VIEW TOP VIEW SIDE VIEW ....................................................................................................................................................................................................... 10
Résumé du contenu de la page N° 11
ULTRA FLAME DV “0” Clearance Fireplace INSTALLATION SAFETY NOTICE Improper installation may result in a house fire. Follow installation directions. Installation must be in accordance with local building codes or, in the absence of local codes, with current CAN/CGA B 149 installation codes for gas appliances in Canada and current National Fuel Gas Code ANSI Z223.1 in the USA. INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. THIS GAS FIREPLACE MUST BE VENTED OUTSIDE. THIS
Résumé du contenu de la page N° 12
ULTRA FLAME DV “0” Clearance Fireplace VENT TERMINAL LOCATION Your Ultra Flame fireplace vents through a vent terminal installed on the roof or on the outside of any exterior wall of your house. Many restrictions apply to the vent terminal location that should be considered before locating your fireplace. The following drawing presents a summary of most of these restrictions. A = 12" Clearance above grade, veranda, porch, deck or balcony B = 12" Clearance to window or door th
Résumé du contenu de la page N° 13
ULTRA FLAME DV “0” Clearance Fireplace J = 12" Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance K = 72" Clearance to a mechanical air supply inlet L = 84" Clearance above paved sidewalk or a paved driveway located on public property M =36" Clearance under veranda, porch, deck, or balcony A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves
Résumé du contenu de la page N° 14
ULTRA FLAME DV “0” Clearance Fireplace Top of fireplace (spacer) 0" Back of fireplace 0" Sides of fireplace 0" Bottom of fireplace 0" Vent pipe: 2" Wall perpendicular to the standard surround 1/2" Mantel (from upper part of the standard surround) 6" if the projection is up to 6" 12" if the projection is over 6" NOTE: If you install decorative posts to support the mantel shelf, they can be located 1/2" away from the side of the fireplace
Résumé du contenu de la page N° 15
ULTRA FLAME DV “0” Clearance Fireplace • Check the gas line piping for leaks. Use a soap and water solution. WARNING: DO NOT USE OPEN FLAME TO CHECK LEAKS. You are now ready to proceed to the venting kit installation. 15
Résumé du contenu de la page N° 16
ULTRA FLAME DV “0” Clearance Fireplace VENTING KITS STRAIGH OUT CORNER RADIATION SHIELD 10-1/2" X 10-1/2" OPENING 29-1\2"FOR STRAIGHT OUT "K" CUT TO LENGTH 39-1\4" FOR CORNER INSTALLATION KIT BASEMENT THROUGH THE WALL DETAIL 16
Résumé du contenu de la page N° 17
ULTRA FLAME DV “0” Clearance Fireplace Once the position of the fireplace and the termination cap are fixed, you should select the venting kit appropriate for your needs. First floor installations require either a STRAIGHT OUT kit or a CORNER kit while basement installations must be done with a BASEMENT kit. Please note that the BASEMENT kit can also be used on first (or higher) floors and it is possible to use up to 25' of pipe with a distant installation. 1) STRAIGHT OUT INSTALLATION
Résumé du contenu de la page N° 18
ULTRA FLAME DV “0” Clearance Fireplace • Add a spring spacer. The spring spacer must be located opposite the outside pipe joints to prevent puncturing of the inside pipe when the two sections of the outside pipe are screwed together. • Slip on the 90° x 8" elbow so that it faces your hole in the wall. Seal it with silicone and secure with screws. • Add a spring spacer. • Add sections of 8" diameter pipe and cut it to be flush with the outside face of the exterior wall, and install the
Résumé du contenu de la page N° 19
ULTRA FLAME DV “0” Clearance Fireplace VENTING SYSTEM 19
Résumé du contenu de la page N° 20
ULTRA FLAME DV “0” Clearance Fireplace VENT TERMINAL, STRAIGHT OUT AND CORNER INSTALLATION Seal with RTV silicone between 8" diameter pipe and radiation shield inside and outside the building to prevent air passage. Install the vent terminal as shown. Insert the wall plate inside the 8" pipe and screw it to the wall using the six #10 2-1/2" wood screws supplied. Place the 5" locking band around the inner connector and insert the exhaust pipe. Seal the joint with RTV silicone. Secu