Résumé du contenu de la page N° 1
VERTICAL FLOAT SUMP PUMP
Model 95591 - .75 HP
Model 95592 - 1 HP
Model 95593 - 1.5 HP
SET UP And OPERATIng InSTRUCTIOnS
Diagrams within this manual may not be drawn proportionally.
Due to continuing improvements, actual product may differ slightly from the product described herein.
®
distributed exclusively by Harbor Freight Tools .
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our website at: http://www.harborfreight.com
Read this material before using this product.
Failure to do so can
Résumé du contenu de la page N° 2
SPECIFICATIOnS Model 95591 Model 95592 Model 95593 Motor 115 V~ / 60 Hz / 4 A 115 V~ / 60 Hz / 5.5 A 115 V~ / 60 Hz / 6 A / 3/4 HP / 1 HP / 1.5 HP Power Switch Type Automatic Float Switch Power Plug Type 3-Prong / Grounded Self Priming Yes Maximum Pumping Capacity 3,000 GPH 3,300 GPH 3,700 GPH Maximum delivery Height 20’ 24’ 26’ discharge diameter 1-1/2 NPT Female / 1-3/4 NPT Male Max. Operating Temperature 95° Fahrenheit SAVE THIS MAnUAL You will need this manual for the safety warnings and pr
Résumé du contenu de la page N° 3
ELECTRICAL SAFETY 1. grounded tools must be plugged into a gFCI (ground Fault Circuit Interrupt - er) outlet, properly installed, and grounded in accordance with all codes and ordinances. never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. If the tools should electrically malfunction or break down, grounding provides a low resistance path to car
Résumé du contenu de la page N° 4
2. Store idle equipment out of reach of children and other untrained persons. Electrically-powered products are dangerous in the hands of untrained users. 3. Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect this product’s operation. If damaged, have the Sump Pump serviced before using. Many accidents are caused by poorly maintained equipment. SERVICE 1. Service must be performed only by qualified repair personnel. Service or ma
Résumé du contenu de la page N° 5
This Pump is designed to move clean or dirty water only. Do not pump water hotter than 95 degrees Fahrenheit. 7. Make sure the discharge pipe (not included) is secured to a solid surface to ensure the stability of the Pump. 8. Make sure to position the Pump on a flat, level, solid surface. 9. Arrange a “drip loop” in the Power Cord connecting the Pump to a 115 volt, gFCI electrical outlet. A drip loop is that part of the Power drip Loop Cord below the level of the outlet to prevent water f
Résumé du contenu de la page N° 6
of electric shock. (See 3-Prong Plug gROUndIng and Outlet.) TO PREVEnT WARnIng 2. The grounding prong in the plug is ELECTRIC connected through the green wire in- SHOCK And dEATH FROM side the cord to the grounding system InCORRECT gROUndIng in the tool. The green wire in the cord WIRE COnnECTIOn: must be the only wire connected to Check with a qualified the tool’s grounding system and must electrician if you are in doubt never be attached to an electrically as to whether the ou
Résumé du contenu de la page N° 7
2. Double insulated tools may be used dition. Always replace a damaged in either of the 120 volt outlets shown extension cord or have it repaired by in the preceding illustration. (See a qualified electrician before using it. Outlets for 2-Prong Plug.) 8. Protect the extension cords from sharp objects, excessive heat, and Extension Cords damp or wet areas. 1. Grounded tools require a three wire RECOMMEndEd MInIMUM WIRE extension cord. Double Insulated gAUgE FOR EXTEnSIOn CORdS* tools
Résumé du contenu de la page N° 8
UnPACKIng When unpacking, check to make sure all the parts shown on the Parts List on page 12 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible. ASSEMBLY And OPERATIng InSTRUCTIOnS note: For additional information regarding the parts listed in the following pages, refer to the Assembly diagram on page 13. WARnIng! Always make sure to turn off the electricity powering the Pump’s electrica
Résumé du contenu de la page N° 9
CHECK VALVE FIgURE E OR UnIOn (nOT InCLUdEd) TO 115 VOLT, gROUndEd gFCI OUTLET dISCHARgE PIPE (nOT InCLUdEd) 1/8” AIR BLEEd HOLE o BASE (25) 3. Connect the Discharge Pipe to the Base (25). nOTE: Make sure the Discharge Pipe is secured to a solid surface, with appropriate hardware (not included), to ensure the stability of the Pump. (See Figure E.) 4. Install an additional union (not included) or other means of separating the Dis- charge Pipe just above the floor to facilitate removal of the
Résumé du contenu de la page N° 10
6. Carefully set the Pump in place. do not lower or raise the Pump by the Power Cord or discharge Pipe. (See Figure E.) 7. The Float Switch (2) automatically switches on and off at a water depth of approxi- mately 4 inches. The ON/OFF height can be manually changed by adjusting the Float Switch Lock. CAUTIOn: Do not run the Pump dry. Doing so will increase wear to the unit and possibly cause seal damage. (See Figure E.) 8. nOTE: This Pump has a built-in thermal protector for the Motor
Résumé du contenu de la page N° 11
2. To clean the Impeller Cover and Impeller: A clogged or dirty Impeller Cover or Impeller (28) will greatly reduce performance of the Pump. To clean the Impel- ler Cover (31), spray the Cover with clean water. To clean the Impeller, remove the nine Screws (32) at the bottom of the Base (25). Then, remove the Base to expose the Impeller Cover and Impeller. Use a stream of clean water to clean the Impeller and Impeller area inside the Pump. Then, replace the Base. (See Assy. diagram.)
Résumé du contenu de la page N° 12
PLEASE REAd THE FOLLOWIng CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS,
Résumé du contenu de la page N° 13
ASSEMBLY dIAgRAM SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 PAGE 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Power Cord/Plug not shown. 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. *Internal Motor Parts Are Not Consumer-Serviceable.
Résumé du contenu de la page N° 14
LIMITEd 90 dAY WARRAnTY Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this prod- uct is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installat