Résumé du contenu de la page N° 1
Solar Water Heater Instruction for use
QBJ1-130A58E
QBJ1-150A58E
QBJ1-175A58E
QBJ1-200A58E
QBJ1-230A58E
QBJ1-270A58E
Please read this manual before usage
Retain it for future reference
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
Content Technical data Features 1 Appearance and parts 1 Technical parameter 1 Precautions 2 Before use 3 Notice 3 Assembly Instruction The location 4 Exterior and installation dimension 4 Tank assembly 5 Frame assembly 5 Frame fastness 5 Glass tube assembly 6 7 Extraventricular plumbing instructions 7 Indoor plumbing instructions Installation notice 8 Pipelines thermal insulation notice 9 The product with controller installation and using notice 9 Using Instruction The operation method 10 Tr
Résumé du contenu de la page N° 4
Technical data Features 1. Inner cylinder: SUS 304 stainless steel, food grade. 2. Insulation: Polyurethane foam, thickness-45 mm, good heat preservation effect. 3. Outer shell: Aluminium / zinc coated steel sheet. 4. Frame: Steady structure, shapely and durable . Appearance and parts Outer shell Cover Silicon seal ring Evacuated tubes Frame Foot cushion Base support Technical parameter Models QBJ1-130A58E QBJ1-150A58E QBJ1-175A58E QBJ1-200A58E QBJ1-230A58E QBJ1-270A58E Specification of
Résumé du contenu de la page N° 5
Precautions Precautions 1.When using the water heater with electric heating, ensure that electric heating and electric tracing belt are closed. 2. Avoiding irradiation without water after installation, it can't be used immediately, it should be sheltered. 3. When supplying water at the first time, it should be operated in the morning or evening or the condition of short of light; avoid supplying water in strong sunshine, in order to prevent vacuum tubes bombing. 4. If the water pressu
Résumé du contenu de la page N° 6
Before use Notice Please take time to read this manual and familiarize yourself with the function of this production. 1. Please check out the packing list. 2.If you fix electric auxiliary heating and controller, please select Haier equipped products. 3. To avoid the scald, please mix the hot and the cold water before use it. 4. In order to protect the tank ,please don't refit or wall up the air supply pipe and the overflow pipe. 3
Résumé du contenu de la page N° 7
Assembly Instruction The location: 1. Please install the solar water heater in the area that avoid the thunder. 2. Solar water heater angle range: east to south for 10 , west to south for 15 . 3. There shouldn't be any hindrance in front of the heater ,or the distance should over L, L=H/tg(66.5 a) H:height of the hindrance; a: latitude of the area Notice: The solar water heater shall be installed by professional. Exterior and installation dimension: Exterior dimension(mm) Installati
Résumé du contenu de la page N° 8
Assembly Instruction Tank assembly 1. Unpacking the tank, rip off the protection film. Uninstall the nut and cushion. 2. Place tank onto tank bracket cradle, inserting protruding bolts into holes. fasten with nuts. Notice: 1. Rip off the protection film after the installation to avoid the destroy of the tank, and please don't use the sharp tool. 2. Leave nuts loose since some adjustment may be necessary after fitting tubes. 3. When assembling the water tank, keep the center line of vacuu
Résumé du contenu de la page N° 9
Assembly Instruction Glass tube assembly 1. Keep tubes out of the irradiation while assembling the unit or a scald may be caused. 2. Place the rounded side of rubber seal downwards on the open end of tubes.(A) 3. Insert the tube into base support of locating hole with gentle pressure and twisting motion. 4. Holding the tube, fix base support into base bracket (B), insert tube into base support (C). 5. Slide the tube down 1 cm, Slide black rubber seal up the tubes until it sits flush
Résumé du contenu de la page N° 10
Assembly Instruction Extraventricular plumbing instructions Air supply pipe Over flow pipe Sensor Electric heating pipe Over flow hole ( Air supply hole(1/2 ) conect to the room forbidden to stem Electric heating flange Inlet/outlet hole (1/2 ), conect Sensor hole 3/4 to the room a b A QBJ1-130A58E QBJ1-150A58E QBJ1-175A58E QBJ1-200A58E QBJ1-230A58E QBJ1-270A58E A b a Remarks: The permitted error limit of above parameters is 10%. Indoor plumbing instructions Solar water heater Connect the
Résumé du contenu de la page N° 11
Assembly Instruction Installation notice 1. Any alteration to the structure of the solar water heater may cause the trouble while using it. 2. There are 5 connection methods of the water pipe into the room, they are smoke way, vent-pipe hole on the wall appropriative solar well prepared cannula and the first three kinds are common. Before the installation, our professional will consult the room's situation and choose the suitable location to bring you convenience. A upend slope is necess
Résumé du contenu de la page N° 12
Assembly Instruction Pipelines thermal insulation notice 1.Outdoor pipelines should be thermal insulated according to local climate, bad thermal insulation may lead to heat loss. 2.The outlet used by electric tracing belt must ground reliably. The rated current of outlet is less than 10A, ensure is connected to plug reliably. 3.Fixing electric tracing belt on cold and hot water pipes, in order to touch well, it should be fixed with insulating tape per 500 mm. 4.Waterproof should be tied
Résumé du contenu de la page N° 13
Assembly Instruction Using Instruction 7.If the controller you choose has automatic water supply function, electromagnetic valve must be fixed in room horizontally; the direction of arrowhead labled on valve is the direction of water running out. Suggest fixing manual water supply side line, ensure that users can use water heater normally when the electromagnetic valve is damaged. 8.If the supply cord is damaged, in order to avoid danger, it must be replaced by factory or maintenance de
Résumé du contenu de la page N° 14
Using Instruction Troubles treatment Possible reason Treatment Phenomenon Supply water according to the The tank is empty manual No water supply The pipeline or the connection Maintain the pipeline or clean is impeded the connection The controller The evacuated tubes have Replacing the tubes can't reach the damaged programmed The water supply is paused or low level or there is Waiting for the supplying again water pressure no water Maintain the pipeline and The pipeline or the connec
Résumé du contenu de la page N° 15
Résumé du contenu de la page N° 16
Made in China Rev. 01 Specific Number 0040500680F