Instruction d'utilisation Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT

Instruction d'utilisation pour le dispositif Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT

Dispositif: Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT
Catégorie: Réchauffeur d'eau
Fabricant: Desa
Dimension: 1.9 MB
Date d'addition: 6/26/2014
Nombre des pages: 42
Imprimez l'instruction

Téléchargez

Comment utiliser?

Notre objectif consiste à vous assurer le plus rapide accès au contenu de l'instruction d'utilisation du dispositif Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT. En utilisant l'aperçu en ligne vous pouvez parcourir le sommaire et passer à la page où vous trouverez la résolution de votre problème avec Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT.

Pour votre confort

Si regarder l'instruction Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT directement sur la page n'est pas confortable pour vous, vous pouvez profiter de deux solutions possibles:

  • Exploration au mode de plein écran - pour analyser l'instruction d'une manière commode (sans l'avoir téléchargée sur votre ordinateur) vous pouvez utiliser le mode d'exploration en plein écran. Pour démarrer l'exploration de l'instruction Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT en plein écran, utilisez le bouton Plein écran.
  • Téléchargement sur l'ordinateur - vous pouvez aussi télécharger l'instruction Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT sur votre ordinateur et la sauvegarder dans vos ressources. Si vous n'avez pas envie de gaspiller votre espace disque, vous pouvez toujours télécharger cette instruction du ManualsBase dans l'avenir.
Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT Manuel d'utilisation - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Version imprimée

Beaucoup de gens préfèrent de lire les documents dans la version imprimée et non pas sur l'écran. L'option d'impression de l'instruction est aussi prévue et vous pouvez en profiter en cliquant le lien ci-dessus - Imprimez l'instruction. Il n'est pas nécessaire d'imprimer toute l'instruction Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT - on peut choisir des pages. Economisez le papier.

Résumés

Vous trouverez ci-dessous les annonces des contenus qui se trouvent sur les pages suivantes de l'instruction de Desa CGD3924NT, CGD3930NT, CGD3018NT, CGB3924NT, CGB3930NT, CCL3018NT, CCL3924NT, CCL3930NT. Si vous voulez parcourir rapidement le contenu des pages suivantes de l'instruction, vous pouvez en profiter.

Résumés du contenu
Résumé du contenu de la page N° 1

BILTMORE SPLIT OAK, MOUNTAIN OAK,
PREMIUM AGED SPLIT OAK, AND
SMOKY MOUNTAIN OAK UNVENTED (VENT-FREE)
NATURAL GAS LOG HEATERS
VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGNED CERTIFIED
AS VENTED DECORATIVE APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
18", 24", and 30" Variable 18", 24" and 30"
Manually-Controlled Models Thermostatically-
Controlled Models
CGD3018N CY2718N
CGD3924N CY3124N
CGD3924NT CGD3930NT
CGD3930N
CGD3018NT CGB3924NT
CGB3930NT CCL3018NT
Patent
CCL3924NT CCL3930NTA
Pen

Résumé du contenu de la page N° 2

VENT-FREE NATURAL GAS LOG HEATER 4. Before installing in a solid fuel burn- SAFETY Due to high temperatures, the ing fireplace, the chimney flue and fire- appliance should be located out INFORMATION box must be cleaned of soot, creosote, of traffic and away from furniture ashes, and loose paint by a qualified and draperies. WARNINGS chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue IMPORTANT: Read this owner’s Do not place clothing or other for damage. If damaged, ope

Résumé du contenu de la page N° 3

OWNER’S MANUAL SAFETY LOCAL CODES Install and use heater with care. Follow all local INFORMATION codes. In the absence of local codes, use the Continued latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*. 14. Turn heater off and let cool before ser- vicing. Only a qualified service person *Available from: should service and repair heater. American National Standards Institute, Inc. 15. Operating heater above elevations of 1430 Broadway 4,500 feet could cause pilot o

Résumé du contenu de la page N° 4

VENT-FREE NATURAL GAS LOG HEATER Confined and Unconfined Space PROVIDING ADEQUATE PRODUCT VENTILATION The National Fuel Gas Code, ANS Z223.1 FEATURES defines a confined space as a space whose The following are excerpts from National Continued volume is less than 50 cubic feet per 1,000 Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- 3 Btu per hour (4.8 m per kw) of the aggre- SAFETY PILOT tion 5.3, Air for Combustion and Ventilation. gate input rating of all appliances installed This heater has a pilot

Résumé du contenu de la page N° 5

OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = _________________ cu.

Résumé du contenu de la page N° 6

VENT-FREE NATURAL GAS LOG HEATER AIR FOR 12" COMBUSTION AND VENTILATION Ventilation Continued Ventilation Grills Grills Into Adjoining Room, Into Adjoining Or VENTILATION AIR Option 2 Room, Remove Option 1 Ventilation Air From Inside Door into Adjoining Building Room, This fresh air would come from an adjoining Option unconfined space. When ventilating to an 3 adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the 12" flo

Résumé du contenu de la page N° 7

OWNER’S MANUAL CHECK GAS TYPE INSTALLATION WARNING: Never install the Use only natural gas. If your gas supply is heater NOTICE: This heater is intended not natural gas, do not install heater. Call • in a bedroom or bathroom un- for use as supplemental heat. Use dealer where you bought heater for proper less installed as a vented ap- this heater along with your pri- type heater. pliance (Variable Manually- mary heating system. Do not in- Controlled Models Only) (see stall this heater as your pr

Résumé du contenu de la page N° 8

VENT-FREE NATURAL GAS LOG HEATER If Using Mantel Minimum Noncombustible INSTALLATION Material Clearances You must have noncombustible material(s) Continued above the fireplace opening. Noncombus- If Not Using Mantel Minimum Clearances For Side tible materials (such as slate, marble, tile, Note: If using a mantel, proceed to If Using Combustible Material, Side Wall, etc.) must be at least 1/2 inch thick. With Mantel. If not using a mantel, follow the sheet metal, you must have noncombustible and

Résumé du contenu de la page N° 9

OWNER’S MANUAL Mantel Shelf INSTALLATION 10" Underside of Continued 8" Mantel Shelf 6" MANTEL CLEARANCES 1 2 /2" In addition to meeting noncombustible mate- All minimum rial clearances, you must also meet required distances are clearances between fireplace opening and in inches mantel shelf. If you do not meet the clear- Minimum Non- (A) Combustible Log Set ances listed in Figure 7, you will need a hood. Material 12" 18" 20" 22" 24" 24"/30" Models Determining Minimum Mantel 3 8" 8" 14" 16 /4"

Résumé du contenu de la page N° 10

VENT-FREE NATURAL GAS LOG HEATER INSTALLATION Continued Damper INSTALLING DAMPER Clamp CLAMP ACCESSORY FOR Damper VENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and Damper constructed of noncombustible material. Clamp If your heater is a manually-controlled model, you may use this heater as a vented product. There are three reasons for operat- ing your heater in the vented mode. Damper Damper 1. The fi

Résumé du contenu de la page N° 11

OWNER’S MANUAL Flexible Gas Hose Installation Items Needed INSTALLATION (if allowed by local • hardware package (provided with heater) Heater Gas Continued codes) Regulator • approved flexible gas hose (not provided) INSTALLING HEATER BASE (if allowed by local codes) ASSEMBLY • sealant resistant to propane (propane/LP) Fitting gas, not provided CAUTION: Do not remove the • electric drill with 3/16" drill bit metal data plates attached to the • flathead screwdriver heater base assembly. The dat

Résumé du contenu de la page N° 12

VENT-FREE NATURAL GAS LOG HEATER Installation must include an equipment We recommend that you install a sediment INSTALLATION shutoff valve, union, and plugged 1/8" NPT trap in supply line as shown in Figure 15. Continued tap. Locate NPT tap within reach for test Locate sediment trap where it is within gauge hook up. NPT tap must be upstream reach for cleaning. Install in piping system CONNECTING TO GAS from heater (see Figure 15). between fuel supply and heater. Locate sedi- SUPPLY ment trap wh

Résumé du contenu de la page N° 13

OWNER’S MANUAL Test Pressures Equal To or Less Than Pressure Testing Heater Gas INSTALLATION 1/2 PSIG (3.5 kPa) Connections Continued 1. Close equipment shutoff valve (see Fig- 1. Open equipment shutoff valve (see Fig- ure 16). CHECKING GAS ure 16). 2. Pressurize supply piping system by ei- CONNECTIONS 2. Open main gas valve located on or near ther using compressed air or opening gas meter. main gas valve located on or near gas WARNING: Test all gas pip- 3. Make sure control knob of heater is i

Résumé du contenu de la page N° 14

3 VENT-FREE NATURAL GAS LOG HEATER Front Log (#3) 4. Locate the notches in the bottom of the INSTALLATION crossover log (#4). Place the crossover Continued log on top of the middle log and front log. Make sure the notches of the cross- INSTALLING LOGS over log lines up with rectangular knobs on top of the middle and front logs (see CAUTION: After installation Figure 21). and periodically thereafter, check 5. Place lava rock around base of heater. to ensure that no flame comes in Do not put lava

Résumé du contenu de la page N° 15

OWNER’S MANUAL 4. Locate the notches in the bottom of the Front Log (#4) INSTALLATION front log (#4). Place the front log on Continued the grate fingers. Make sure the notches Notches of the front log line up with the grate Dual Burner Premium Aged fingers. See Figure 25. Split Oak Models 5. With knot to right side, place smaller log piece (#5) over the pin on the left WARNING: Failure to position side of the middle log. The smaller log the parts in accordance with these will rest on front log

Résumé du contenu de la page N° 16

VENT-FREE NATURAL GAS LOG HEATER 4. Locate holes on the bottom of crossover 5. For CCL3924NT and CCL3930NTA INSTALLATION log (#4). Slide front hole onto the left Only: Locate peg and hole on the bot- Continued peg (CCL3924NT or CCL3930NTA) tom of crossover log (#5). Slide the peg or middle peg (CCL3018NT) on the into the hole located in crossover log Dual Burner Biltmore Split Oak middle log (#2) and the peg on the back (#4). Slide the hole onto the peg on Models log (#3). See Figure 30 for plac

Résumé du contenu de la page N° 17

6 7 OWNER’S MANUAL Single Burner Mountain Oak INSTALLATION Front Log Models (#2) Continued Recess 32. WARNING: Failure to position 6. Locate holes on the bottom of cross- the parts in accordance with these over log (#6). Slide these holes onto the diagrams or failure to use only Notch right pegs located in middle log (#2) parts specifically approved with and front log (#1). See Figure 33. this heater may result in property damage or personal injury. 7. For CCL3930NTA only: Locate holes on the b

Résumé du contenu de la page N° 18

VENT-FREE NATURAL GAS LOG HEATER 4. Wait five (5) minutes to clear out any OPERATING LIGHTING gas. Then smell for gas, including INSTRUCTIONS HEATER near the floor. If you smell gas, STOP! Follow “B” in the safety in- Manually-Controlled Models formation above. If you don’t smell WARNING: gas, go to the next step. FOR YOUR SAFETY • If fireplace has glass doors, 5. Slightly depress and turn control knob READ BEFORE never operate this heater with counterclockwise C-clockwise to the PI- LIGHTING g

Résumé du contenu de la page N° 19

OWNER’S MANUAL Thermostatically-Controlled OPERATING LIGHTING Models INSTRUCTIONS HEATER Continued FOR YOUR SAFETY READ BEFORE WARNING VARIABLE CONTROL • If fireplace has glass doors, LIGHTING OPERATION never operate this heater with glass doors closed. If you op- The variable control valve can be set to erate heater with doors closed, WARNING: If you do not fol- any heat setting and flame height desired, heat buildup inside fireplace low these instructions exactly, a by simply turning the cont

Résumé du contenu de la page N° 20

LO Pilot VENT-FREE NATURAL GAS LOG HEATER 7. Keep control knob pressed in for 30 OPERATING MANUAL LIGHTING seconds after lighting pilot. After 30 PROCEDURE HEATER seconds, release control knob. Note: If pilot goes out, repeat steps 1. Follow steps 1 through 5 under Light- Continued 3 through 7. This heater has a safety ing Instructions, pages 19 and 20. 5. Turn control knob counterclockwise interlock system. Wait one (1) minute 2. Depress control knob and light pilot C-clockwise to the PILOT pos


Instructions pareilles
# Instruction d'utilisation Catégorie Téléchargez
1 Desa 15 Manuel d'utilisation Réchauffeur d'eau 0
2 Desa 6000 BTU/HR Manuel d'utilisation Réchauffeur d'eau 2
3 Desa and CVDR30 Manuel d'utilisation Réchauffeur d'eau 0
4 Desa B Manuel d'utilisation Réchauffeur d'eau 0
5 Desa A, C, B Manuel d'utilisation Réchauffeur d'eau 0
6 Desa CBT30NT, CBT30PT Manuel d'utilisation Réchauffeur d'eau 0
7 Desa CBN20T Manuel d'utilisation Réchauffeur d'eau 0
8 Desa CCL3018NTA Manuel d'utilisation Réchauffeur d'eau 0
9 Desa CCL3018NA Manuel d'utilisation Réchauffeur d'eau 0
10 Desa CCL3018PTA Manuel d'utilisation Réchauffeur d'eau 0
11 Desa CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB Manuel d'utilisation Réchauffeur d'eau 0
12 Desa CCL3924NA Manuel d'utilisation Réchauffeur d'eau 0
13 Desa CCL3924NTA Manuel d'utilisation Réchauffeur d'eau 0
14 Desa CCL3930NTB Manuel d'utilisation Réchauffeur d'eau 0
15 Desa CDR3924NT Manuel d'utilisation Réchauffeur d'eau 0
16 A.O. Smith 000 Manuel d'utilisation Réchauffeur d'eau 8
17 A.O. Smith 101 Manuel d'utilisation Réchauffeur d'eau 3
18 A.O. Smith 12 40GPC T 100 Manuel d'utilisation Réchauffeur d'eau 4
19 A.O. Smith 104 Series Manuel d'utilisation Réchauffeur d'eau 3
20 A.O. Smith 104 - 110 Manuel d'utilisation Réchauffeur d'eau 6