Instruction d'utilisation Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL

Instruction d'utilisation pour le dispositif Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL

Dispositif: Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL
Catégorie: Réchauffeur d'eau
Fabricant: Amtrol
Dimension: 0.57 MB
Date d'addition: 7/15/2014
Nombre des pages: 8
Imprimez l'instruction

Téléchargez

Comment utiliser?

Notre objectif consiste à vous assurer le plus rapide accès au contenu de l'instruction d'utilisation du dispositif Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL. En utilisant l'aperçu en ligne vous pouvez parcourir le sommaire et passer à la page où vous trouverez la résolution de votre problème avec Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL.

Pour votre confort

Si regarder l'instruction Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL directement sur la page n'est pas confortable pour vous, vous pouvez profiter de deux solutions possibles:

  • Exploration au mode de plein écran - pour analyser l'instruction d'une manière commode (sans l'avoir téléchargée sur votre ordinateur) vous pouvez utiliser le mode d'exploration en plein écran. Pour démarrer l'exploration de l'instruction Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL en plein écran, utilisez le bouton Plein écran.
  • Téléchargement sur l'ordinateur - vous pouvez aussi télécharger l'instruction Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL sur votre ordinateur et la sauvegarder dans vos ressources. Si vous n'avez pas envie de gaspiller votre espace disque, vous pouvez toujours télécharger cette instruction du ManualsBase dans l'avenir.
Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL Manuel d'utilisation - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Version imprimée

Beaucoup de gens préfèrent de lire les documents dans la version imprimée et non pas sur l'écran. L'option d'impression de l'instruction est aussi prévue et vous pouvez en profiter en cliquant le lien ci-dessus - Imprimez l'instruction. Il n'est pas nécessaire d'imprimer toute l'instruction Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL - on peut choisir des pages. Economisez le papier.

Résumés

Vous trouverez ci-dessous les annonces des contenus qui se trouvent sur les pages suivantes de l'instruction de Amtrol Pre-Pressurized Water System Tanks WELL-X-TROL. Si vous voulez parcourir rapidement le contenu des pages suivantes de l'instruction, vous pouvez en profiter.

Résumés du contenu
Résumé du contenu de la page N° 1


WELL-X-TROL PROFESSIONAL
Pre-Pressurized
Water System
Tanks

Résumé du contenu de la page N° 2

® WELL-X-TROL Professional revolutionizes the industry ® WELL-X-TROL Professional redefined the industry with its advanced engineering and innovative product design including the pre-pressurized well tank, sealed-in air charge, and unique water chamber design. With proven performance since 1963, WELL-X-TROL Professional continues to deliver unparalleled results making it the most trusted choice of professionals in today’s market.WELL-X-TROL Professional offers many unique feature

Résumé du contenu de la page N° 3

Advanced design features continue to set industry standards n Stainless steel air valve is welded in position rather than mechanically threaded to prevent loss of air pressure and to minimize stress on the well’s pump system. It also carries a tamper-evident warning label. Dome n Deep-drawn steel domes offer twice the strength of rolled steel while minimizing weight. Hoop n Unique positive hoop ring seal secures diaphragm and liner for added strength and reliabilit

Résumé du contenu de la page N° 4

esp(Effective System Protection): maximum system output with minimal pump starts The ESP sizing procedure covers modern residential water-use habits, increased off-peak demands and the general increase in water use that have occurred over the past twenty-five years. ESP sizing is designed to reduce pump wear and tear, and reduce energy consumption by keeping pump starts to a minimum. Choose the amount of protection you need. ESP I: Tank selection is based on approximately one minute m

Résumé du contenu de la page N° 5

WELL-X-TROL Professional tank operation time-tested design WELL-X-TROL Professional has a sealed in air chamber that is pre-pressurized before it leaves our factory. Air and water do not mix. 1 When the pump starts, water enters the WELL-X-TROL Professional. Only usable 2 water is stored. When the pressure in the chamber reaches cut-out pressure, the pump 3 stops. The WELL-X-TROL Professional is filled. When water is demanded, pressure in the air chamber forces water into the system. Since

Résumé du contenu de la page N° 6

WELL-X-TROL Professional residential models In-Line Models Dimensions Total Max. System Drawdown Shipping Model Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.) No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft) WX-101 8 12 5/8 2.0 0.45 .8 .7 .6 5 (0.6) WX-102 11 15 4.4 0.55 1.8 1.5 1.3 9 (1.2) WX-103 11 22 1/4 7.6 0.42 3.1 2.6 2.2 15 (1.8) WX-104 15 3/8 17 3/4 10.3 1.00 4.1 3.5 3.0 20 (2.6) WX-200 15 3/8 22 14.0 0.81 5.6 4.8 4.1 22 (3.3) Precharge Pressure for WX

Résumé du contenu de la page N° 7

WELL-X-TROL Professional specialty residential models Pump Stand Models Dimensions Total Max. System Drawdown Shipping Model Height Width Length Volume Accept. 20/40 30/50 40/60 Wt. (Vol.) No. (ins) (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft) WX-105-PS 11 10 9/16 18 1/4 5.3 0.80 2.1 1.8 1.6 13 WX-200-PS 16 15 3/8 20 7/8 14.0 0.81 5.6 4.8 4.1 29 Precharge Pressure is 30 PSIG and Sys. Conn. is 3/4" NPTM Fitting for 103-PS and 105-PS; and 1" NPTF Coupling for 200-PS. Maximu

Résumé du contenu de la page N° 8

AMTROL has innovative ways to help you grow your business Water Treatment Technologies ® ® Hydrogen Sulfide Removal System Arsenic Removal System Iron Removal System Water Softening and Filtration Hydronic Technologies Boiler Expansion Tanks Water Heater Expansion Tanks Indirect-Fired Water Heaters ® Ask for Quality. Ask for AMTROL . Corporate Headquarters AMTROL Canada, Ltd. 1400 Division Road 275 Shoemaker Street West Warwick, RI 02893 Kitchener, Ontario N2E 3B3 Te


Instructions pareilles
# Instruction d'utilisation Catégorie Téléchargez
1 Amtrol WH-7 Classic Series Manuel d'utilisation Réchauffeur d'eau 2
2 Amtrol HYDROMAX HM-80L Manuel d'utilisation Réchauffeur d'eau 4
3 Amtrol HYDROMAX HM-41L Manuel d'utilisation Réchauffeur d'eau 1
4 Amtrol WH-9 Classic Series Manuel d'utilisation Réchauffeur d'eau 1
5 Amtrol BoilerMate Top Down Manuel d'utilisation Réchauffeur d'eau 20
6 Amtrol Therm-X-Trol Manuel d'utilisation Réchauffeur d'eau 1
7 Amtrol HYDROMAX HM-80Z Manuel d'utilisation Réchauffeur d'eau 0
8 Amtrol HYDROMAX HM-41Z Manuel d'utilisation Réchauffeur d'eau 0
9 Amtrol BoilerMate RTR Manuel d'utilisation Réchauffeur d'eau 0
10 A.O. Smith 000 Manuel d'utilisation Réchauffeur d'eau 8
11 A.O. Smith 101 Manuel d'utilisation Réchauffeur d'eau 3
12 A.O. Smith 12 40GPC T 100 Manuel d'utilisation Réchauffeur d'eau 4
13 A.O. Smith 104 Series Manuel d'utilisation Réchauffeur d'eau 3
14 A.O. Smith 104 - 110 Manuel d'utilisation Réchauffeur d'eau 6
15 A.O. Smith 105 Series Manuel d'utilisation Réchauffeur d'eau 1