Résumé du contenu de la page N° 2
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
Résumé du contenu de la page N° 3
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 One 1/4” blade screwdriver One wire stripper MATERIALS ! WARNING Wiring outlet box and box connectors must be of Before assembly your ceiling fan, refer to section type required by the local code. The minimum wire on proper method of wir
Résumé du contenu de la page N° 4
Electrical Requirements Your new ceiling fan will require a grounded electrical ! WARNING supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and Turning off wall switch is not sufficient. To avoid capable of withstanding a load of at least 50 pounds. possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and ! Local codes and the ceiling fan must be properly WARNING
Résumé du contenu de la page N° 5
How to Put Your Ceiling Fan Together (continued) 3. Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the DOWNROD SETSCREW PIN downrod until it rests on the motor housing. Place HANGER the ceiling cover over the downrod. Be sure that BALL the ceiling cover and the coupling cover are both CEILING oriented correctly (Figure 3). COVER 4. Reinstall the hanger ball (Figure 3) on the downrod as follows. Route the three 80” motor leads through COUPLING
Résumé du contenu de la page N° 6
How to Put Your Ceiling Fan Together (continued) 11. Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connector latch closes properly. ! WARNING SWITCH HOUSING CONNECTOR To reduce the risk of personal injury, do not bend the MOTOR CONNECTOR blade flange when installing the blade flanges, balancing the blades or cleaning the fa
Résumé du contenu de la page N° 7
How to Hang Your Ceiling Fan CEILING ! WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). AT LEAST 7' ! WARNING FLOOR The outlet box and joist must be securely mounted and Figure 9 capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”. NOTE: CEILING COVER OUTLET OMITTED FOR CLARITY. ! WARNING BOX To reduce the risk of fire, electrical shock, or personal injury, mount fan to o
Résumé du contenu de la page N° 8
How to Wire Your Ceiling Fan If you feel that you do not have enough electrical BLUE wiring knowledge or experience, have your fan BLACK FAN WIRE YELLOW FAN FAN WIRE GROUND installed by a licensed electrician. WIRE WIRE LISTED ! WARNING WHITE SUPPLY WIRE (NEUTRAL) CONNECTOR (3) To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, GREEN WIRE
Résumé du contenu de la page N° 9
4 3 2 1 0 4 3 2 1 0 Wall Control Installation The fan speed control is designed to operate only one ceiling fan, and not an accessory light kit. This wall control is rated for 1.2 amps at 120 volts. To avoid erratic speeds and possible damage to your ceiling fan, use this control only with the fan pull chain switch set to its high speed setting. NOTE: The “0” position is OFF. The four fan speeds are selected by sliding the bar to the other four speed positions (“1”, “2”, “3” and “4”). WALL 1. Be
Résumé du contenu de la page N° 10
Operation of Reverse Switch All fans are shipped from the factory with the reversing switch positioned to circulate air downward. If airflow is desired in the opposite direction, turn your SLIDE REVERSE SWITCH fan off and wait for the blades to stop turning, then RIGHT OR LEFT TO slide the reversing switch to the opposite position, and CHANGE BLADE DIRECTION turn fan on again. The fan blades will turn in the opposite direction and reverse the airflow (Figure 17). • Warm weather - (Counterclockw
Résumé du contenu de la page N° 11
Maintenance IMPORTANT CARE INSTRUCTIONS Abrasive cleaning agents are not required and should for your Ceiling Fan be avoided to prevent damage to finish. Periodic cleaning of your new ceiling fan is the only ! WARNING maintenance that is needed. When cleaning, use only a soft brush or lint free cloth Do not use water when cleaning your ceiling fan. It to avoid scratching the finish. could damage the motor or the blades and create the possibility of an electrical shock. Trouble Shooting WARNING:
Résumé du contenu de la page N° 12
Repair Parts 2 1 3 13 11 14 4 10 12 15 4 20 3 5 2 1 6 0 7 18 16 17 9 19 8 U.L. Model No.: CF901 12
Résumé du contenu de la page N° 13
Repair Parts Listing Key Model Numbers No. Description CF901BS00 CF901CK00 CF901GES00 CF901ORB00 CF901VNB00 * Hanger Ball Assembly, 761655-17 761655-23 761655-35 761655-32 761655-89 Consisting of: 1 Hanger Bracket — — — — — 2 Hanger Ball — — — — — 3 Downrod (4.5”) — — — — — * Parts Bag Containing: 764111-1 764111-1 764111 764111 764111 4 Wire Connector (3) — — — — — 5 Pin, Clevis (1) — — — — — 6 Clip, Hairpin (1) — — — — — 7 Screw, Washer Head, #10-24 x 7mm (16) — — — — — 8 Screw, Pan Head, 1/4-
Résumé du contenu de la page N° 14
Notes 14 U.L. Model No.: CF901
Résumé du contenu de la page N° 15
LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your
Résumé du contenu de la page N° 16
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP74460000 Printed in China 12/11 Form No. BP7446 U.L. Model No.: CF901