Résumé du contenu de la page N° 2
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! CONTENTS OF USER’S MANUAL DANGER - IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR CARBON MONOXIDE POISONING. ITEM PAGE # PRECAUTIONS - SAFETY GUIDE 1 W A R N I N G S : 1. INTRODUCTION 2 1. RISK OF INDOOR AIR POLLUTION! 2. FEATURES 2 • Use this heater only in well ventilated areas. Provide at least a three-square foot (2,800 sq
Résumé du contenu de la page N° 3
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! 3. UNPACKING AND ASSEMBLY 1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. NOTE : Save the shipping carton and packing materials for future storage. RMC-KFA/65TDLX RMC-KFA120TDLX R M C - K FA 1 7 0TDLX Wheel No Yes Yes Wheel Bar No Yes Yes Wheel Cap No Yes Yes Front Handle No Yes Yes Handle Yes Yes Yes Cord Wrap Yes Yes Yes Screws Yes No No Screws(A) and Screws(B) No Yes Yes Bushing No
Résumé du contenu de la page N° 4
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! 2. ASSEMBLY A. For RMC-KFA65TDLX Model only (See Figure 6,7) Tools Required • Medium Phillips Screwdriver 1. Assembling Handle. 1) Align boss on bottom of handle with the 2 holes on the shell cover as shown in Figure 6 NOTE : Be sure to match the tab in the bottom of the handle with the slot in housing cover. 2) Insert screws into the holes in the handle and tighten each screw. Figure 6. Handle Ass
Résumé du contenu de la page N° 5
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! 5. OVERVIEW OF HEATERS DESIGN 7. OPERATION Fuel System : This heater is equipped with an electric A.) VENTILATION air pump that forces air through the air RISK OF INDOOR AIR POLLUTION/USE HEATER ONLY IN WELL VENTILATED AREAS. line connected to the fuel intake and then Provide a fresh air opening of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr. through a nozzle in the burner he
Résumé du contenu de la page N° 6
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! 8. LONG TERM STORAGE OF YOUR HEATER 9. MAINTENANCE WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR FUEL TANK DRAIN WHILE HOT! 1. Remove Fuel Cap and Cap Fuel Filter(See Figure 10). USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or 2. Drain Fuel Tank through Fuel Cap Opening and wash Fuel Cap Filter with clean fuel. other alternate components will void warranty and may caus
Résumé du contenu de la page N° 7
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! D.) FAN BLADES F.) SPARK PLUG CLEAN EVERY SEASON OR AS NEEDED. CLEAN AND REGAP EVERY 600 HOURS -Remove upper shell(See 10 page.) OF OPERATION OR REPLACE AS NEEDED. -Use 1/8" allen wrench to loosen set screw -Remove upper shell(See 10 page). which holds Fan Blade to motor shaft. -Remove Fan Blade(See 11 Page). - Slip Fan Blade off motor shaft. -Remove Ignitor Wire from Spark Plug. -Clean Fan
Résumé du contenu de la page N° 8
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! H.) FUEL FILTER 10. TROUBLE SHOOTING GUIDE CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEED. -Remove upper shell(See 10 page). -Remove Fan Blade(See 11 Page). -Pull Fuel Line off from Fuel Filter Neck. -Remove Fuel Filter. -Wash Fuel Filter with clean kerosene and replace in tank. -Attach Fuel Line to Fuel Filter Neck. -Replace Fan Blade and Upper Shell. Figure 18. Removing Fuel Filter I.) PUMP
Résumé du contenu de la page N° 9
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! 11. WIRING DIAGRAM 12. SPECIFICATIONS A) WIRING DIAGRAM(RMC-KFA65TDLX) RMC-KFA65TDLX K FA 1 2 0 T- D L X K FA 1 7 0 T- D L X H 25" 25" D 32.1" 36.9" B) WIRING DIAGRAM(RMC-KFA120TDLX/RMC-KFA170TDLX) W 18.5" 18.5" RMC-KFA120TDLX / RMC-KFA170TDLX M O D E L R M C - K FA 6 5 T D L X R M C - K FA 1 2 0 T D L X R M C - K FA 1 7 0 T D L X B T U / H r . 6 5 , 0 0 0 1 2 0 , 0 0 0 1 7 0 , 0 0 0 Fuel Consumptio
Résumé du contenu de la page N° 10
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! 13. EXPLODED PARTS DRAWING 14. PARTS LIST(RMC-KFA65TDLX Model Only) KEY NO. D E S C R I P T I O N P A R TN O . KEY NO. D E S C R I P T I O N P A R TN O . Capacitor 1 Fuel Tank Assembly 3211-0018-00 23-2 3820-0142-00 Motor Supportor 2 Fuel Gauge 2156-0023-00 23-3 3121-0358-00 Lock Nut. 3 Fuel Gauge Cap 3231-0123-00 23-4 4331-0022-00 Pump Body 4 Fuel Cap Filter 3221-0063-00 23-5 3541-0022-00 Bolt-PH
Résumé du contenu de la page N° 11
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! 15. EXPLODED PARTS DRAWING(RMC-KFA120T/170TDLX Models Only) 16. PARTS LIST(RMC-KFA120T/170TDLX Models Only) PART NO. KEY NO. DESCRIPTION RMC-KFA120TDLX RMC-KFA170TDLX Fuel Tank Assembly 2151-0012-00 2151-0011-00 1 Fuel Gauge 2156-0022-00 2156-0022-00 2 Fuel Gauge Cap 3231-0123-00 3231-0123-00 3 Fuel Cap Filter 3221-0063-00 3221-0063-00 4 Fuel Cap 3231-0122-00 3231-0122-00 5 Fuel Filter Assembly 2155
Résumé du contenu de la page N° 12
NEVER LEAVE THE HEATER NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNATTENDED WHILE BURNING! 17. PARTS LIST (WHEELS AND HANDLE) PART NO. KEY NO. DESCRIPTION RMC-KFA120TDLX RMC-KFA170TDLX 1) RMC-KFA65TDLX MODEL 23-8 Rotor Kit SP-KFA1000 SP-KFA1000 23-9 Blade See SP-KFA1000 See SP-KFA1000 PART NO. KEY DESCRIPTION QTY 23-10 End Pump Cover 3531-0008-00 3531-0008-00 NO. RMC-KFA65TDLX 23-11 Nipple(Air) 3541-0020-00 3541-0020-00 1 Handle 3231-0125-00 1 23-12 Flange Bolt 4329-0014-00 4329-0014-00