Résumé du contenu de la page N° 1
USERS INFORMATION MANUAL
MODEL TSTATBBPS701
PROGRAMMABLE DIGITAL
Heating & Cooling Systems
THERMOSTAT
NOTE TO INSTALLER:
This manual must be left with the equipment user.
7 Day Programmable
4 Time Periods per Day
o Auto Changeover
Am
6:03
Su 70
COOL
AUTO
Large, Easy To Read
HEAT
o
68 67
Display
Thermoglow Backlight
Very Easy to Program
Programmable Fan
No Batteries Required
Heat Pump & Heat Cool
Outdoor Temperature
Sensor Available
Meets California Title 24 Residential
Résumé du contenu de la page N° 2
Table Of Contents FRONT PANEL 2 DISPLAY 3 QUICK START Set the clock and go 5 BASIC OPERATION 6 PROGRAMMING 4 Time Periods 8 ADVANCED SETUP 12 ABOUT ADVANCED OPERATION 17 WARRANTY 23 CAUTION Follow Installation Instructions before proceeding. SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS. Residential Light Commercial Systems Carrier Corporation 4/01 TSTATBBPS101 Page 1
Résumé du contenu de la page N° 3
Front Panel Backlit LCD Display o Am Warmer or + Button 6:03 70 Su COOL AUTO HEAT o 68 67 Cooler or - Button Mode Button Heat or Cool Indicator Red = Heat, Green = Cool Programmable Thermostat o Am 6:03 70 S COOL AUTO HEATo 68 67 FAN OUTSIDE VACATION PROGRAM SET CLOCK MODE FAN OUTSIDE VACATION PROGRAM SET CLOCK Page 2
Résumé du contenu de la page N° 4
Display 11 1 10 7 o ProgramOn Setup Am 4 : Start Locked Pm 12:00 2 88 SMTWTFS 1 9 COOL ServiceFilter AUTO 1 5 Outside Night OFF HEAT 1 o 6 MorningDay Evening 4 8 88 88 Fan On 3 1 Mode Indicators Selects the operation mode of the equipment. HEAT - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies.
Résumé du contenu de la page N° 5
Display 5 Outside Indication Indicates the temperature displayed is from the optional outside sensor. Page 21. 6 Morning, Day, Evening & Night Indication Indicates the program time period. Page 8-11. 7 Setup Indication Indicates the thermostat is in the programming mode. Page 12. 8 Fan Operation Indication Fan On - indicates constant, continuous fan operation. When Fan On is not lit - indicates the fan will only operate when n
Résumé du contenu de la page N° 6
Quick Start Set the Clock and Go During Setup & Programming: SET CLOCK Press the SET CLOCK Pressing the Up and Down button. buttons will modify the flashing selection. . (Represented in dark black) Setup Am : 12:00 i To adjust the Press clock or Day use MODE Setup 2 S buttons. SET CLOCK Press the SET CLOCK button as above to return to normal operation. This thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming.
Résumé du contenu de la page N° 7
Basic Operation Select Mode : Pm 12:00 M The HEAT setting indicates the temperature the room has to HEAT o Press reach before the furnace will MODE turn on to heat the room. 70 69 o : Pm 12:00 The COOL setting indicates the 72 M COOL temperature the room has to reach before the air conditioner will turn on to cool the room. Press 70 MODE o : Pm 12:00 72 M AUTO will automatically select COOL heat or cool based on room AUTO temperature demand. HEAT o Press 70 69 MODE o ProgramOn : 12:00Pm Prog
Résumé du contenu de la page N° 8
Basic Operation In any mode, adjust the Select Desired Temperature desired Set Temperature o with : 12:00Pm 72 M COOL AUTO HEAT o 70 69 buttons. Pressing the Up or Down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously. Pressing the Up or Down buttons in Heat or Cool modes will adjust only the heat or cool set temperature. Press Fan FAN Operation o : Pm 12:00 85 S Fan On indicates constant fan operation. COOL This feature is active even if the thermostat H
Résumé du contenu de la page N° 9
Programming 4 Time Periods Press Press the PROGRAM button to enter time period programming. PROGRAM Use the back cover Programming Worksheet to help with this section. M Select the day of week (M - S) Press MODE Am : Start 7 30 M Adjust the start time for Morning. Morning Press MODE o Am : 7 30 74 M Adjust the cooling COOL setpoint for Morning. (35 - 99 ) Morning Press MODE o Am : 7 30 74 M Adjust the heating COOL setpoint for Morning. (35 - 99 ) HEAT o Morning Press MODE 72
Résumé du contenu de la page N° 10
Programming 4 Time Periods Am : Start I0 30 M Adjust the start time for Day. Day Press MODE o Am : I0 30 75 M Adjust the cooling COOL setpoint for Day. (35 - 99 ) Day Press MODE o Am : I0 30 75 M Adjust the heating COOL setpoint for Day. (35 - 99 ) HEAT o Day Press 73 MODE : Start 5 30Pm Adjust the start time M for Evening. Evening Press MODE o : 5 30 Pm 75 M Adjust the cooling COOL setpoint for Evening. (35 - 99 ) Press Evening MODE Continued Page 9
Résumé du contenu de la page N° 11
Programming 4 Time Periods o : Pm 5 30 75 M Adjust the heating COOL setpoint for Evening. HEAT o (35 - 99 ) Evening Press 73 MODE : Start I I 30 Pm M Adjust the start time for Night. Night Press MODE o : I I 30 Pm 78 M Adjust the cooling COOL setpoint for Night. Night (35 - 99 ) Press MODE o Am : I I 30 78 Adjust the heating M COOL setpoint for Night (35 - 99 ) Night HEAT o Press 70 MODE Continued Page 10
Résumé du contenu de la page N° 12
Programming 4 Time Periods The copy command becomes available after programming the entire previous day. Yes : 18:no Select Yes or No to copy T the previous day’s program to this day. No co py If No is selected: If Yes is selected: Selecting Yes, then pressing mode will copy the previous day’s program and then will ask the Press same copy question again. If yes is selected MODE Press each time, this routine will repeat. MODE If No is selected, as in previous steps, flashing pro
Résumé du contenu de la page N° 13
Advanced Setup Press the Mode button. MODE While holding the Mode, NOTE: Each step # is located at press the Program button the top right corner of the PROGRAM display for easy reference. to enter Setup screens. Setup AM I2:00 Adjust the time of day I clock. Tip: To change hours quickly, press and hold the override button in and press Press the up or down buttons. MODE Setup Mo 2 Select the day of the week. Press MODE Setup On 3 Select residential Heat Pump,
Résumé du contenu de la page N° 14
Advanced Setup Setup On 5 Select Electric Heat On or Off. (Step 5 only appears if heat pump is OFF off in step 3) Off EH Press MODE Setup 88 6 Adjust the deadband from 1 - 6 degrees. 2 Press MODE Setup 8If 7 Adjust the minimum COOL difference between cooling & heating setpoints. HEAT (0 - 6 ) 2 Press MODE Setup Select the cycles per hour limit. 8 d=cycles per hour limit defeated. d1=d + defeat 5 min. Compressor lockout. (d, d1, 2 - 6) 6 Cy Press MODE Setup : 0:00 9 Adjust the programmab
Résumé du contenu de la page N° 15
Advanced Setup On Setup Am 7:00 I0 Adjust the programmable fan start time. (step 10 appears only if step 9 is not 0:00) Press Fan On MODE Setup 9:00Pm I I Adjust the programmable fan stop time. (step 11 appears only if step 9 OFF is not 0:00) Press Fan On MODE On Setup On I2 Select the display back- light always On, or Off after 8 seconds. Press Off L I MODE Setup Press 0 I3 Reset the Energy Watch Heat hour counter. FAN HEAT (0 - 1999) Press MODE Setup Press 0 I4 COOL Reset the Energ
Résumé du contenu de la page N° 16
Advanced Setup Setup 0 Press I5 Reset the Service Filter ServiceFilter counter. This will also remove the Service Filter icon from the FAN display Press MODE Setup Adjust the number of 0 hours the blower will I6 ServiceFilter run before the Service Filter icon appears on the display. 0 = off. (0 - 1950) Press MODE Setup C I7 Select thermostat operation in degrees Fahrenheit or Centigrade. F Press F MODE Press the Mode button. FAN While holding the Mode, press the Fan button for 2 s
Résumé du contenu de la page N° 17
Advanced Setup Advanced Setup Table Step # Description Range Factory Default 1 Time of day clock set 24 hour 12:00 Am 2 Day of the week Sun - Sat Monday 3 Heat Pump Off / On Off 4 Reversing Valve polarity
Résumé du contenu de la page N° 18
About Advanced Features & Operation MEMORY BACKUP - In the event of a power loss, the thermostat will retain the stored program settings without external power or batteries. 2 STAGE OPERATION - The 2nd Stage of heat or cool is turned on when (1) the 1st Stage has been on for a minimum of two minutes, and (2) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 degrees. Heating Cooling Dead
Résumé du contenu de la page N° 19
About Advanced Features & Operation EMERGENCY HEAT - Is a feature available to Heat Pump installations. To turn on Emergency Heat press in the Fan button. While holding the Fan button press the Up button for 2 seconds. The Cool setpoint display will read ‘EH’. o Am : 12:00 eh Press for Emergency Heat HEAT o 73 74 FAN During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat, when there is a demand for heat, locking
Résumé du contenu de la page N° 20
About Advanced Features & Operation KEYPAD LOCK - To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together. The Locked icon will appear on the display. o : Pm Locked 12:00 85 COOL Press all 3 for Keypad Lockout HEAT o 65 55 MODE To unlock the buttons, again pre