USERS INFORMATION MANUAL
MODEL TSTATBBPB501
PROGRAMMABLE DIGITAL
Heating & Cooling Systems
THERMOSTAT
NOTE TO INSTALLER:
This manual must be left with the equipment user.
Dual Setpoint
I2:00
74
Mo
COOL 5+2 Day Programmable
AUTO
4 Time periods
HEAT
72 Very Easy to Program
70
Easy To Read Display
Thermoglow Backlight
No Batteries Required
Auto Changeover
Heat Pump & Heat Cool
No Batteries Required
Locking Keypad
Meets California Title 24 Residential
Résumé du contenu de la page N° 2
Table Of Contents FRONT PANEL 2 DISPLAY 3 QUICK START Set the clock and go 5 BASIC OPERATION 6 PROGRAMMING 4 Time Periods 8 ADVANCED SETUP 12 ABOUT ADVANCED OPERATION 16 WARRANTY 21 CAUTION Follow Installation Instructions before proceeding. SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS. Residential Light Commercial Systems Carrier Corporation 04/01 TSTATBBPB501 Page 1
Résumé du contenu de la page N° 3
Front Panel I2:00 Mo 74 COOL 1 AUTO HEAT 72 70 3 2 5 4 1 Liquid Crystal Display with Thermoglow 2 Up/Down Buttons 3 Mode Button 4 Fan Button 5 Heat or Cool Indicator Heat = Red, Cool = Green Page 2
Résumé du contenu de la page N° 4
Display 5 6 Night Am 2 4 Pm Setup I2:00 88 SuMoTuWeThFrSa COOL 1 AUTO Locked 8 3 ONOFF Program On 1 HEAT 88 5 MorningDayEvening 4 Fan On 88 7 1 Mode Indicators Selects the operation mode of the equipment. HEAT - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies. OFF - indicates the entire sys
Résumé du contenu de la page N° 5
Display 5 Morning, Day, Evening & Night Indication Indicates the program time period. Page 8-11. 6 Setup Indication Indicates the thermostat is in the programming mode. Page 12. 7 Fan Operation Indication Fan On - indicates constant, continuous fan operation. When Fan On is not lit - indicates the fan will only operate when necessary to heat or to cool. Page 7. 8 Locked Indication Locked appears after the right combination
Résumé du contenu de la page N° 6
Quick Start Set the Clock and Go Press the Mode button. During Setup & Programming: While holding the Mode, MODE Pressing the Mode button press the Fan button selects different flashing items. for 2 seconds to enter Setup (Represented in dark black) FAN screens. Pressing the Up and Down buttons will modify the flashing I2:00 I selection. To adjust the Press clock or Day use MODE SuMoTuWeThFrSa 2 buttons. Press both Mode and MODE Fan buttons as above to return to FAN normal operation.
Résumé du contenu de la page N° 7
Basic Operation Select Mode I2:00 Su The HEAT setting indicates the temperature the room has to reach before the furnace will 70 turn on to heat the room. 69 MODE I2:00 Su 72 The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room. 70 MODE I2:00 Su 72 AUTO will automatically select heat or cool based on room temperature demand. 70 69 MODE I2:00 Su 73 Program On will activate the stored timer operation. (Morning, Day, Evening, Nigh
Résumé du contenu de la page N° 8
Basic Operation In any mode, adjust the Select Desired Temperature desired Set Temperature I2:00 Pm with Mo 72 COOL AUTO HEAT 70 buttons. 69 Pressing the up/down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously. Pressing the up/down buttons in Heat or Cool modes will adjust only the heat or cool set temperature. Press Fan FAN Operation I2:00 Pm Fan On indicates constant fan operation. Mo 72 This feature is active even if the thermostat COOL is set t
Résumé du contenu de la page N° 9
Programming 4 Time periods Press the Mode button. While holding the Mode, press the Up button for 2 seconds to enter time period programming. MODE MoTuWeThFr Select the Day of the Week. MoTuWeThFr or SaSu. (Weekday or Weekend schedule) Press MODE Am 7:30 MoTuWeThFr Adjust the start time for Morning. Press Morning MODE Am 7:30 MoTuWeThFr 74 COOL Adjust the cooling setpoint for Morning. (35 - 99 ) Press Morning MODE Am 7:30 MoTuWeThFr 74 Adjust the heating s
Résumé du contenu de la page N° 10
Programming 4 Time Periods Am I0:30 MoTuWeThFr Adjust the start time for Day. Press Day MODE Am I0:30 75 MoTuWeThFr COOL Adjust the cooling setpoint for Day. (35 - 99) Press Day MODE Am I0:30 75 MoTuWeThFr COOL Adjust the heating setpoint for Day. (35 - 99) HEAT Press Day 73 MODE 5:30 Pm MoTuWeThFr Adjust the start time for Evening. Press Evening MODE 5:30 Pm 75 MoTuWeThFr COOL Adjust the cooling setpoint for Evening. (35 - 99) Press Evening MODE Continued Page
Résumé du contenu de la page N° 11
Programming 4 Time Periods 5:30 Pm 75 MoTuWeThFr COOL Adjust the heating setpoint for Evening. (35 - 99) HEAT Press Evening 73 MODE Night I I:30 Pm MoTuWeThFr Adjust the start time for Night. Press MODE Night I I:30 Pm 78 MoTuWeThFr COOL Adjust the cooling setpoint for Night. (35 - 99) Press MODE Night I I:30 Pm 78 MoTuWeThFr COOL Adjust the heating setpoint for Night. (35 - 99) HEAT 70 Press MODE Continued Page 10
Résumé du contenu de la page N° 12
Programming 4 Time Periods Su Sa Select the Day of the Week. MoTuWeThFr or SaSu. (Weekday or Weekend schedule) Press MODE Continue Time Period Programming Morning through Night as done in previous steps starting on page 8 for the Weekend schedule. To Exit Programming Press the Mode button. While holding the Mode, press the Up button for 2 seconds to exit time period programming. MODE Page 11
Résumé du contenu de la page N° 13
Advanced Setup Press the Mode button. MODE While holding the Mode, NOTE: Each step # is located at press the Fan button the top right corner of the for 5 seconds to enter Setup display for easy reference. FAN screens. Am I2:00 Setup I Adjust the time of day clock. Tip: To change hours quickly, press and Press hold the Fan button in and press the up or down buttons. MODE Mo Setup 2 Select the day of the week. Press MODE On Setup 3 Select residential He
Résumé du contenu de la page N° 14
Advanced Setup B Setup 4 Select the reversing valve polarity for Heat Pump, O or B. (Step 4 only appears if heat pump is on in step 3) O 0 Press MODE Setup 5 Select Electric Heat On or Off. (Step 5 only appears if heat pump is off in step 3) OFF Eh Press MODE 88 Setup 6 Adjust the deadband from 1 - 6 degrees. 2 Press MODE 81f Setup 7 Adjust the minimum COOL difference between cooling & heating setpoints. HEAT (0 - 6 ) 2 Press MODE Continued Page 13
Résumé du contenu de la page N° 15
Advanced Setup Select the cycles per Setup 8 hour limit. d=cycles per hour limit defeated. d1=d + defeat 5 min. Compressor lockout. 6 (d, d1, 2 - 6) Cy Press MODE On Setup 9 Select the display back- light always On, or Off after 8 seconds. ON L I Off Press MODE C Setup I0 Select thermostat operation in degrees Fahrenheit or Centigrade. F F MODE FAN Press the Mode button. While holding the Mode, press the Fan button for 2 seconds to leave the Setup screens. If no buttons are pressed
Résumé du contenu de la page N° 16
Advanced Setup Advanced Setup Table Step # Description Range Factory Default 1 Time of day clock set 24 hour 12:00 Am 2 Day of the week Sun - Sat Monday 3 Heat Pump Off / On Off 4 Reversing Valve polarity
Résumé du contenu de la page N° 17
About Advanced Features & Operation 2 STAGE OPERATION - The 2nd Stage of heat or cool is turned on when (1) the 1st Stage has been on for a minimum of two minutes, and (2) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 degrees. Heating Cooling Dead Dead Band Band 2 degrees 2 degrees 2nd Stage 1st Stage Heat Cool 1st Stage 2nd Stage turn on turn on turn on Setpoint Setpoint turn on MINIMUM HEAT/COOL SETPOINT
Résumé du contenu de la page N° 18
About Advanced Features & Operation EMERGENCY HEAT - Is a feature available to Heat Pump installations. To turn on Emergency Heat press in the Fan button. While holding the Fan button press the Up button for 2 seconds. The Cool setpoint display will read ‘EH’. I2:00 Su eh Press for Emergency Heat 73 74 Fan During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat, when there is a demand for heat, locking out the 1st
Résumé du contenu de la page N° 19
About Advanced Features & Operation KEYPAD LOCK - To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together. The Locked icon will appear on the display. Am Night I2:00 S Su u 85 COOL Press all 3 for Locked Keypad Lockout ProgramOn HEAT 70 MODE 55 To unlock the
Résumé du contenu de la page N° 20
About Advanced Features & Operation DUAL SETPOINT BEHAVIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, including programming Occupied and Unoccupied periods, the 1050 will not allow the Heat setpoint to get closer to the Cool setpoint than the value programmed as the minimum difference in