Résumé du contenu de la page N° 1
Installation Instructions / Warranty
ThermoBalance II Deck Valve
Metris S Focus S Solaris E Stratos E
06401XX0 06405000 06450XX0 06451XX0
Metro E Talis S C Cross C Scroll
06452XX0 06453XX0 06454XX0 06455XX0
Allegro² E Metro² E
C Lever Solaris² E
06456XX0 04185XX0 04198XX0
04172XX0
Résumé du contenu de la page N° 2
ThermoBalance II Deck Valve 06401XX0 Metris S 06454XX0 C Cross 06405000 Focus S 06455XX0 C Scroll 06450XX0 Solaris E 06456XX0 C Lever 06451XX0 Stratos E 04172XX0 Solaris² E 06452XX0 Metro E 04185XX0 Allegro² E 06453XX0 Talis S 04198XX0 Metro² E 06401XX0 06405XX0 06450XX0 06451XX0 06452XX0 06453XX0 06454XX0 06455XX0 06456XX0 2
Résumé du contenu de la page N° 3
04172XX0 04185XX0 04198XX0 Technical Specification Recommended pressure 45 - 72 psi Maximum hot water temp. 165° F* Recommended hot water temp. 120° - 140° F* Flow rate @ 44 PSI 8 gpm Safety stop 100° F 1/2" female NPT inlets Maximum mounting surface thickness 1 3/8" Hole size in mounting surface 2 3/8" *Know and follow all applicable local plumbing codes when setting the temperature on the water heater. Installation Considerations • For best results, Hansgrohe recommends that this u
Résumé du contenu de la page N° 4
Install the rough Remove the upper mounting ring. upper mounting Screw the lower mounting ring and ring washer to their lowest position. sealing ring Insert the rough up through the hole. Install the upper mounting ring. Tighten it as far as it will go without forcing it. washer lower mounting ring Rest the rough on the mounting surface. Tighten the lower mounting ring and washer. Tighten the tensioning screws. washer lower mounting ring tensioning screws Install the plaster shield. 4
Résumé du contenu de la page N° 5
Install the hot and cold water supply lines* Wrap the threads on the hot and cold supply pipes with Teflon tape. Install the hot and cold supplies to the corresponding inlets. If the supplies are not connected to the correct inlets, the valve cannot function properly! hot inlet cold inlet Install the outlet lines* Wrap the threads on the outlet lines with Teflon tape. Install the lines to the outlets. If only one outlet is to be used, do not plug the second outlet. Tie the two o
Résumé du contenu de la page N° 6
Install the valve trim Remove the plaster shield. Push the escutcheon over the valve. Install the handle. Tighten the screw with a 3 mm Allen wrench. The screw must engage the slot on the cartridge. Justify the handle. Set the high temperature limit stop, if required. slot Justify the handle Turn the water on to the tub spout or hand- shower. Place a thermometer in the water stream. Turn the temperature control knob until the output water temperature is 100°F. Turn the water off. Loos
Résumé du contenu de la page N° 7
Hold the handle lever in one hand. With the other hand, turn the tempera- ture control knob until the 100° mark is next to the indexing mark on the handle. Install the handle on the valve. Tighten the screw. Set the high temperature limit stop (optional) Turn the water on to the tub spout or handshower. Use a 3 mm Allen wrench to loosen the handle screw. Remove the handle from the valve. Carefully remove the retainer clip and the limit stop ring (1). Turn the temperature control ste
Résumé du contenu de la page N° 8
Maintenance: Clean the filters CAUTION: Turn off the water at the main or with the service stops, before opening the valve. Remove the handle and escutcheon. Grasp the wrench flats on the cartridge stop unit with a wrench. Hold the stop unit still with one wrench. Use a second wrench or a 17mm deep socket wrench to unscrew and remove the thermostatic cartridge. Failure to hold the stop unit steady while unscrewing or replacing the thermostat cartridge will result in damage to the stop
Résumé du contenu de la page N° 9
Justify the handle. User instructions From the off position, turn the diverter lever clockwise or counter-clockwise to obtain water from either of the two functions. Turn the temperature control knob clockwise to make the water cooler. Turn it counter-clock- wise to make the water warmer. When turning the knob counter-clockwise, it will stop when the output water is 100°. To ob- tain water hotter than 100°, push downward on the temperature control knob and continue turning it counter-cloc
Résumé du contenu de la page N° 10
Replacement parts 5 4 6 3 12 10 9 7 8 2 13 14 1 11 1 cartridge with shutoff unit 88586000 2 thermostat cartridge 94282000 3 Solaris handle 88528XX0 4 Stratos handle 88543XX0 5 Metro handle 88548XX0 6 Talis handle 88549XX0 7 Cross handle 88608XX0 8 Scroll handle 88609XX0 9 Lever handle 88610XX0 10 Metris handle 11 Focus handle 12 escutcheon 13 Allegro² handle 14 Metro² handle XX = color code 00 = chrome 62 = oil rubbed bronze 82 = brushed nickel 83 = polished nickel 10
Résumé du contenu de la page N° 11
Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets, kitchen faucets, and showers consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain criteria when cleaning. Cleaning Materials for Faucets and Showers Acids are a necessary ingredient of cleaning materials for removing lime, however please pay attention to the follow- ing points when cleaning fauce
Résumé du contenu de la page N° 12
THIS WARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT PAY FOR: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration, or (2) the use of abrasive or caustic cleaning agents or “no-rinse” cleaning products, or the use of the product in any manner contrary to the product instruc- tions. (