Résumé du contenu de la page N° 1
EXCELL PRECISION CO., LTD.
DIGITAL HIGH PRECISION
WEIGHING SCALES
USER INSTRUCTIONS
© Excell Precision Limited 2006. All rights reserved Worldwide.
The information contained herein is the property of Excell Precision Limited and is
supplied without liability for errors or omissions. No part may be reproduced or used
except as authorised by contract or other written permission. The copyright and the
foregoing restriction on reproduction
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
EXCELL PRECISION CO., LTD. TABLE OF CONTENTS BEFORE USING THE SCALE.....................................................................................................3 PREPARING TO USE THE SCALE.............................................................................................3 INTRODUCTION..........................................................................................................................4 1. FEATURES...............................................
Résumé du contenu de la page N° 4
EXCELL PRECISION CO., LTD. 2. RELAY OUTPUT.................................................................................................................23 (1) Relay Output..................................................................................................................23 (2) Relay Pin Description ....................................................................................................23 (3) Connection Illustration ........................................
Résumé du contenu de la page N° 5
EXCELL PRECISION CO., LTD. BEFORE USING THE SCALE To enable you to use this scale correctly, we suggest that you read this manual carefully. 1. Do not use scale in areas with excessive water and don’t spray the scale or indicator with water when cleaning. Remove all water from the scale and indicator with a clean dry cloth. 2. The load placed on the platform must not exceed the maximum weighing capacity of the scale. 3. Keep the scale away from high temperatures and da
Résumé du contenu de la page N° 6
EXCELL PRECISION CO., LTD. INTRODUCTION 1. FEATURES 1. Dual-weighing units: Kilogram (kg) and pound (lb). 2. Multi-function operation: Full range tare; Pre-tare; Hold function; Net / Gross weight display; Simple counting; Preset weight value and quantity value; Adjustable noise filter setting from 01 ~ 15 (≥15,000 division configuration only); Check-weighing configuration. 3. User-friendly design: ♦ Auto calibration ♦ AC / DC power supply ♦ Large LCD display with built
Résumé du contenu de la page N° 7
EXCELL PRECISION CO., LTD. 2. SPECIFICATIONS The available capacities for selection are different and depend on various models: Capacity Division 3 kg (6 lb) 0.2 g (0.0005 lb) 6 kg (12 lb) 0.2 g (0.0005 lb) 7.5 kg (15 lb) 0.5 g (0.001 lb) 15 kg (30 lb) 1 g (0.002 lb) 30 kg (60 lb) 2 g (0.005 lb) 75 kg (60 lb) 5 g (0.01 lb) 150 kg (150 lb) 10 g (0.02 lb) 300 kg (600 lb) 20 g (0.05 lb) 600 kg (1200 lb) 50 g (0.1 lb) Operating Temperature: 0°C ~ 40°C (32°F ~ 104°F) OI
Résumé du contenu de la page N° 8
EXCELL PRECISION CO., LTD. LCD DISPLAY SYMBOLS 1 2 3 4 5 HIGH : Preset High Limit Weight Value OK : The range between Low & High Limit Weight Value LOW : Preset Low Limit Weight Value kg : “kg” unit lb : “lb” unit Pcs : “COUNTING” mode indicating the number of pieces à0ß : “ZERO” indication and platform stable confirmation Net : “Net Weight ”indication : “Low Battery” indication 61 : (STABLE) “Stab
Résumé du contenu de la page N° 9
EXCELL PRECISION CO., LTD. KEYBOARD FUNCTION UNITS 1. : Units Key to choose the desired unit weight (kg or lb). 2. : Preset High & Low Limit value. ^ / 3. : Ù ⇒ Data Entry Key, ⇒ Backlight Key. / 4. : ↵ ⇒ Print Key to print the total data ; ↵ ⇒ Confirmation Key. 5. : Sample Key to set the sample quantity. Pcs 6. : Accumulation Key to add the displayed value into memory. M+ 7. : Re-call accumulated or preset high & low limit
Résumé du contenu de la page N° 10
EXCELL PRECISION CO., LTD. OPERATION 1. DISPLAY BACKLIGHT ^ / Press the key to choose the desired display backlight mode: . ⇒ “Auto Backlight” mode. When the weight is over 10 divisions or any key is pressed, the display backlight will be switched on. When the weight returns to zero or the weight on platform is less than 10 divisions, the display backlight will switch off after 5 seconds. . ⇒ Display backlight is on all the time. . ⇒ Di
Résumé du contenu de la page N° 11
EXCELL PRECISION CO., LTD. I. Weight Totalising DISPLAY ACTION kg . 6 Place the object onto the STABLE scale. The display shows kg the weight value . 6 STABLE Press the M+ key The display shows the total number of additions The total weight totalised kg rd shows and the 3 “6” . 6 flashes on the display 6 M+ STABLE v The totalising function can be used up to
Résumé du contenu de la page N° 12
EXCELL PRECISION CO., LTD. (3). Deduction of the Container Weight I. The weight of the container is unknown ( Tare ) DISPLAY ACTION kg Place the container onto the . scale 6 STABLE T Press the key when the kg weight is stable. Net . The weight value becomes 6 zero and the (Net) symbol is STABLE displayed kg Place the object into the Net . container and the display 6 sh
Résumé du contenu de la page N° 13
EXCELL PRECISION CO., LTD. IV. The weight of the container is known (Pre-set tare) DESCRIPTION DISPLAY ACTION kg Press the PT key . The display shows the weight value 6 Use the ∧ key to enter the STABLE of the container with the negative weight value of the container sign and the (Net) symbol. The followed by pressing the ↵ kg second “6” above the (PT) icon Net key indicates the tare is active . 6 6 STABLE
Résumé du contenu de la page N° 14
EXCELL PRECISION CO., LTD. (4). Check Weighing Press the key to enter the check weighing function. Press the key to UNITS return back to the weighing mode. I. Pre-set the “Low limit value”, “High limit value”, and “the buzzer” operation ^ / Press the key to enter the value required and step to the next digit by pressing the key. / ↵ DESCRIPTION DISPLAY ACTION Press the key to select kg the check weig
Résumé du contenu de la page N° 15
EXCELL PRECISION CO., LTD. II. Pre-set the Low limit value only After completing the Low limit value setting, the display shows . . Press the kg key to complete the setting, and the display shows . 6 STABLE v When users only pre-set the Low limit value, the buzzer setting is fixed at: III. High/OK/Low indications
Résumé du contenu de la page N° 16
EXCELL PRECISION CO., LTD. 4. COUNTING FUNCTION . . . . . . Press the key to enter the counting function. Press the key to return back UNITS . . . . to the weighing mode. (1). Sampling DISPLAY ACTION . . . . . . Press the key to enter the . . . . counting function Pcs 6 STABLE Pcs Press to choose the Pcs number of desired items in the 6 sample (10, 20
Résumé du contenu de la page N° 17
EXCELL PRECISION CO., LTD. CONFIGURATION SETTINGS Switch on the scale. While the scale is counting backward to zero, press and hold the →0← key until the display shows the software program version number: “ ”. →0← Release the key, the scale enters the configuration setting mode. is displayed. Press the TARE key Press the Press the Press the Ù Ù Ù k k ke e ey y y Press the TARE key Press the Ù key Press the
Résumé du contenu de la page N° 18
EXCELL PRECISION CO., LTD. 1. CHECK-WEIGHING CONFIGURATION ♦ F8 (Hold) affects access to F4. If F8 is set, access to F4 is denied. T Press the ^ / or key to select the F4 function⇒ the display shows DESCRIPTION DISPLAY ACTION Press the ↵ key to enter the check weighing configuration Press the ↵ key kg for 5 times to clear . 6 the configuration STABLE Press the ∧ key to enter the settings low limi
Résumé du contenu de la page N° 19
EXCELL PRECISION CO., LTD. 2. RS-232 SETTING ♦ J1 and J3 on the RS-232 interface are connected together (short), when the RS-232 interface is connected to a computer. ♦ J2 and J4 on the RS-232 interface arte connected together (short), when the RS-232 interface is connected to a printer. ^ / T Press the or keys to select the F5 function ⇒ the display shows DESCRIPTION DISPLAY ACTION Press the ↵ key 0 Þ No transmiss
Résumé du contenu de la page N° 20
EXCELL PRECISION CO., LTD. 3. EXIT CONFIGURATION SETTINGS T ^ / Press the or key to select the F6 function⇒ the display shows DISPLAY ACTION Press the ↵ key Scale reverts back to the weighing mode V1.1 18 ZSME300000011