Résumé du contenu de la page N° 1
OPERATION MANUAL
MODEL T802
PARAMAGNETIC OXYGEN ANALYZER
© TELEDYNE ADVANCED POLLUTION INSTRUMENTATION
9480 CARROLL PARK DRIVE
SAN DIEGO, CA 92121-5201
USA
Toll-free Phone: 800-324-5190
Phone: 858-657-9800
Fax: 858-657-9816
Email: api-sales@teledyne.com
Website: http://www.teledyne-api.com/
Copyright 2010-2013 07275B DCN6418
Teledyne Advanced Pollution Instrumentation 14 January 2013
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
ABOUT TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TAPI) Teledyne Advanced Pollution Instrumentation, Inc. (TAPI) is a worldwide market leader in the design and manufacture of precision analytical instrumentation used for air quality monitoring, continuous emissions monitoring, and specialty process monitoring applications. Founded in San Diego, California, in 1988, TAPI introduced a complete line of Air Quality Monitoring (AQM) instrumentation, which comply with the United States Enviro
Résumé du contenu de la page N° 4
Teledyne API T802 Paramagnetic O2 Analyzer Operation Manual This page intentionally left blank. ii 07275B DCN6418
Résumé du contenu de la page N° 5
SAFETY MESSAGES Important safety messages are provided throughout this manual for the purpose of avoiding personal injury or instrument damage. Please read these messages carefully. Each safety message is associated with a safety alert symbol, and are placed throughout this manual; the safety symbols are also located inside the instrument. It is imperative that you pay close attention to these messages, the descriptions of which are as follows: WARNING: Electrical Shock Hazard HAZA
Résumé du contenu de la page N° 6
Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 CONSIGNES DE SÉCURITÉ Des consignes de sécurité importantes sont fournies tout au long du présent manuel dans le but d’éviter des blessures corporelles ou d’endommager les instruments. Veuillez lire attentivement ces consignes. Chaque consigne de sécurité est représentée par un pictogramme d’alerte de sécurité; ces pictogrammes se retrouvent dans ce manuel et à l’intérieur des instruments. Les symboles correspondent aux consigne
Résumé du contenu de la page N° 7
WARRANTY WARRANTY POLICY (02024F) Teledyne Advanced Pollution Instrumentation (TAPI), a business unit of Teledyne Instruments, Inc., provides that: Prior to shipment, TAPI equipment is thoroughly inspected and tested. Should equipment failure occur, TAPI assures its customers that prompt service and support will be available. COVERAGE After the warranty period and throughout the equipment lifetime, TAPI stands ready to provide on-site or in-plant service at reasonable rates similar t
Résumé du contenu de la page N° 8
Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 This page intentionally left blank. vi 07275B DCN6418
Résumé du contenu de la page N° 9
ABOUT THIS MANUAL This operation manual, PN 07275, is comprised of multiple documents in PDF format, as listed below. Part No. Rev Name/Description 07275 B T802 Operation manual 06530 C Menu Trees and Software Documentation (inserted as Appendix A in this manual) 07269 A Spare Parts List (located in Appendix B of this manual) 06535 A Expendables Kit (located in Appendix B of this manual) 06532 C Repair Request Form (inserted as Appendix C in this manual) Appendix D Documents: 0738001
Résumé du contenu de la page N° 10
Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 CONVENTIONS USED In addition to the safety symbols as presented in the Important Safety Information page, this manual provides special notices related to the safety and effective use of the analyzer and other pertinent information. Special Notices appear as follows: COULD DAMAGE INSTRUMENT AND VOID WARRANTY ATTENTION This special notice provides information to avoid damage to your instrument and possibly invalidate the warran
Résumé du contenu de la page N° 11
TABLE OF CONTENTS ABOUT TELEDYNE ADVANCED POLLUTION INSTRUMENTATION (TAPI).......................................................................... i Safety Messages ...................................................................................................................................................iii Warranty ................................................................................................................................................................ v
Résumé du contenu de la page N° 12
Table of Contents Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 5.7.1. ID (Machine Identification).....................................................................................................................83 5.7.2. INET (Ethernet) .....................................................................................................................................84 5.7.3. COM1[COM2] (Mode, Baude Rate and Test Port) ......................................................
Résumé du contenu de la page N° 13
Teledyne API T802 Paramagnetic O Analyzer Operation Manual Table of Contents 2 9.4.1. Pressure Calibration............................................................................................................................176 9.4.2. Flow Calibration...................................................................................................................................178 9.5. Calibration of the Optional CO Sensor...............................................................
Résumé du contenu de la page N° 14
Table of Contents Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 12.1.1. Magnetic Properties of O Gas..........................................................................................................219 2 12.1.2. Principle of Measurement..................................................................................................................219 12.2. NDIR Measurement of CO ...........................................................................................
Résumé du contenu de la page N° 15
Teledyne API T802 Paramagnetic O Analyzer Operation Manual Table of Contents 2 Figure 4-1: Front Panel Touchscreen and Display ........................................................................... 64 Figure 4-2: Viewing Test Functions .................................................................................................. 65 Figure 5-1: Analog Output Connector Pin Out.................................................................................. 71 Figure 5-2: Setup for Ch
Résumé du contenu de la page N° 16
Table of Contents Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 Table 4-2: Test Functions Defined .................................................................................................. 66 Table 6-4: Primary Setup Mode Features and Functions................................................................ 67 Table 6-5: Secondary Setup Mode Features and Functions........................................................... 68 Table 5-2: Variable Names (VARS)............
Résumé du contenu de la page N° 17
PART I – GENERAL INFORMATION AND SETUP 07275B DCN6418 15
Résumé du contenu de la page N° 18
Section 1 General Information Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 This page intentionally left blank. 16 07275B DCN6418
Résumé du contenu de la page N° 19
1. INTRODUCTION, FEATURES AND OPTIONS 1.1. T802 OVERVIEW The Model T802 (also referred to as T802) Paramagnetic Oxygen Analyzer is a microprocessor-controlled analyzer that determines the concentration of molecular oxygen (O ) in a sample gas drawn through the instrument. It uses a 2 paramagnetic sensor that relies on the relatively high reactivity of O molecules 2 to magnetic fields to generate a current that is proportional to the amount of O 2 present in the sensor chamber. The T80
Résumé du contenu de la page N° 20
Introduction, Features and Options Teledyne API T802 Paramagnetic O Analyzer Operation Manual 2 HAZARD Strong Oxidizer OXYGEN IS A STRONG OXIDIZER. This is a general purpose instrument designed for usage in nonhazardous areas. Ensure that all safety precautions related combustible gases are followed. Before working with the casing open, be sure to turn off power to the analyzer, and perform air or N gas purging of not only the analyzer inside, but also the sample gas line. 2 In a