Résumé du contenu de la page N° 1
INSTALLER’S & OWNER’S MANUAL
HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER
Dehumidification
The highly efficient Ultra-Aire 100V dehumidifier utilizes refrigeration
to cool the incoming air stream below its dew point. This cooled and
drier air is used to pre-cool the incoming air stream resulting in a
significant increase in overall efficiency. After the pre-cooling stage,
the processed air is reheated by passing through the condenser coil.
The heat removed by the evaporator coil is ret
Résumé du contenu de la page N° 2
TABLE OF CONTENTS Table of Contents Safety Precautions ....................................................................... 3 5.3C On/Off Setting ........................................................ 13 1. Intended Application ................................................................ 4 5.3D Setting Clock Time ................................................. 13 2. Specifications .......................................................................... 4 5.3E Setting Relative Hum
Résumé du contenu de la page N° 3
SAFETY PRECAUTIONS Safety Precautions Read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions is essential to obtain maximum benefit from your Ultra-Aire indoor air quality system. READ AND SAVE THESE INSTRUCTIONS • The device is designed to be installed INDOORS IN A SPACE THAT IS PROTECTED FROM RAIN AND FLOODING. • I nstall the unit with space to access the front panel for maintenance and
Résumé du contenu de la page N° 4
FOR HVAC INSTALLER ONLY the control wires leaving the Ultra-Aire may not be used with certain 1. Intended Application for Ultra-Aire 100V control panels and should be left safely disconnected with wire For the ideal installation, draw air from the central part of the home nuts taped onto the stripped ends. Be sure to consult the electrical and return it to isolated areas of the home like the bedrooms, den, schematic in this manual or on the front panel of the Ultra-Aire utility room, or
Résumé du contenu de la page N° 5
FOR HVAC INSTALLER ONLY a separate supply duct from the Ultra-Aire to each isolated area is to 125 CFM of outside air. Large quantities of outside air will impact recommended. DO NOT draw air directly from the kitchen, laundry, Ultra-Aire performance positively or negatively, depending upon the or basement. All flexible ducting connected to the Ultra-Aire should difference between inside and outside air conditions. Consult the be UL listed. factory by calling 1-800-533-7533 for recommendation
Résumé du contenu de la page N° 6
FOR HVAC INSTALLER ONLY Connect a duct from outside to the 6" collar of the Ultra-Aire if you 3.4G Installation in a Structure with No Existing wish to provide fresh make-up air. Forced Air HVAC Systems When installing the Ultra-Aire in a structure that does not have a Crawlspace Installation: Locate a separate return for the Ultra- forced air HVAC system, a single return for the Ultra-Aire should Aire in a central area of the structure. Duct the supply of the be installed in central open a
Résumé du contenu de la page N° 7
FOR HVAC INSTALLER ONLY dehumidification or when the ventilation timer calls for ventilation. 4.2 Ventilation Timer and Humidity Control Panel See Figure 2: The ventilation timer and humidity control panel 4.5 Ventilation Timer automatically controls both the ventilation and the humidity of The ventilation timer controls the fan and the motorized fresh the living space. The ventilation timer and humidity control panel air damper. When the ventilation timer is activated, the central contains
Résumé du contenu de la page N° 8
FOR HVAC INSTALLER ONLY and the number “1” should remain in the lower right hand corner of the display. The “1” and “OFF” signify the turn off time for the first program. Set the turn off time using the 1…7, h, and m buttons in the same way as described above and continue on to the second through sixth programs. When setting the ventilation programs, you can return to the current time display by sliding the switch in the upper right corner of the timer to RUN. The slide switch in the uppe
Résumé du contenu de la page N° 9
ATTENTION INSTALLER WIRE THE UNIT AND CONTROL PACKAGE AS SHOWN IN THE DIAGRAM BELOW Humidity/Fan Control Panel Humidity Control D.BLU-5 YEL-2 Blower Switch GRN-6 GRN-6 PNK WHT-1 RED-3 YEL-2 Dehumidifier D.BLU-5 Control Part No. 4024155 Do not connect these leads Ventilation Timer/ directly together or damage Humidity Control Panel Optional to the transformer will result. Damper Humidity Control D.BLU-5 YEL-2 VIO-4 ORG GRN-6 L.BLU PNK REd-3 GRN-6 WHT-1 RED-3 GRY YEL-2 Control Part No. 4024125 D
Résumé du contenu de la page N° 10
FOR HVAC INSTALLER ONLY 5. DEH 3000 Digital Control Installation Instructions Control Part No. 4026570 5.1 Specifications Part # (P/N) 4026570 Model: DEH 3000 Digital Control Electrical: 24 VAC Humidity Range: 10 – 95% RH Humidity Accuracy: +/- 5% Output: 3 Amps 24 VAC Relay Capacity 5 Amps Temp Range/Accuracy 2% Size 4.95" wide x 4.19" high 5.2B Wiring FOR HVAC INSTALLER ONLY: WARNING: DO NOT ALLOW THE YELLOW LEAD 5.2 Installation FROM THE ULTRA-AIRE TO CONTACT THE RED OR WHITE LEADS T
Résumé du contenu de la page N° 11
FOR HVAC INSTALLER ONLY Dehumidification Operation COM/NO COM/NC UA Base Unit White ON CLOSED OPEN OFF OPEN CLOSED Common uses (assuming standard thermostat wiring color schemes as noted): Disengage A/C during dehumidification Redirect the yellow thermostat wire to the NC DEH 3000 Wiring Diagram terminal. Wire the yellow wire from the A/C to the COM (B) terminal. Engage A/C during dehumidification DMP COMP FAN Connect a wire from the “R” terminal on the the thermostat to the “com” ter
Résumé du contenu de la page N° 12
FOR HVAC INSTALLER ONLY DEHUMIDIFIER DEACTIVATES WHEN THE motorized damper in series with these connections, or the AIR-CONDITIONER IS RUNNING white wire must not be connected to the control. Mis-wiring • The common wire on the thermostat transformer may result in transformer damage. (black) needs to be wired with the yellow wire from the After connections have been verified, this short test will dehumidifier. confirm proper wiring. • The Red wire on the thermostat needs to be wired with
Résumé du contenu de la page N° 13
FOR HVAC INSTALLER AND HOMEOWNER 8. V erify additional optional control operations such as fan interlock or lockout. 9. Proceed to operation/setting section. FOR INSTALLER & HOMEOWNER: 5.3 Operation 5.3A Display • W hen there is power to the control, the control display will show the time, day, humidity, and temperature. • When the control is turned on, the setpoint, fan status, auto/hold mode, and fresh air vent status is displayed. • When a key is pressed the display will light. • T he
Résumé du contenu de la page N° 14
FOR HVAC INSTALLER ONLY AND HOMEOWNER Operation continuously are filtration and air recirculation. The initial dead band setting (the range that the dehumidifier “AUTO” – indicates the fan will run when the control calls for cycles on and off) is 3%. With a setpoint of 50%, the dumidifier dehumidification or ventilation. If the control has not called for turns on when the reading reaches 53%. The dehumidifier dehumidification for 3 hours, the control will automatically run continues to rem
Résumé du contenu de la page N° 15
FOR HVAC INSTALLER ONLY AND HOMEOWNER The ventilation indicator “O” will be displayed whenever the unit There are two programs available for ventilation Monday through Friday. There are also two programs for Saturday and is ventilating. The fan operation indicator “O” will also be lit. Sunday. No other choice of days is available. There are three damper operation modes, “OPEN –HOLD,” “CLOSED – HOLD” and “PROGRAM” (denoted by “ON TIME” Each program has: – “OFF TIME.” Refer to section 3.8
Résumé du contenu de la page N° 16
FOR HVAC INSTALLER AND HOMEOWNER 2. Press the program enter key to toggle to the “open for” feature will not need to be used. If temperature cutout is desired, setting. Using the up/down “RH” keys, change the program the setpoint by pressing the “PROGRAM ENTER” duration that the damper will ventilate fresh air. button. Press RH until “TEMP CUTOUT” is flashing. Use “RH” up or “RH” down to adjust setpoints. 3. Press the program enter key to toggle to the “closed for” setting. Using t
Résumé du contenu de la page N° 17
FOR HVAC INSTALLER AND HOMEOWNER 6. Maintenance 7. Service 6.1 Standard Air Filter CAUTION: Servicing the Ultra-Aire with its The Ultra-Aire is equipped with a pleated cloth air filter. This filter high pressure refrigerant system and high should be checked monthly. Operating the unit with a dirty filter voltage circuitry presents a health hazard will reduce dehumidifier capacity and efficiency and may cause the which could result in death, serious bodily compressor to cycle off and on un
Résumé du contenu de la page N° 18
FOR HVAC INSTALLER AND HOMEOWNER No dehumidification, compressor does not run but fan runs left in the system, it must be recovered before weighing in the new with fan switch and ventilation timer OFF and humidity control charge. Refer to the unit nameplate for the correct charge weight turned to ON. and refrigerant type. 1.Defective compressor run capacitor (Sec. 5.6). 7.5 Fan Replacement 2.Loose connection in compressor circuit (See Fig. 4). The centrifugal fan has a PSC motor and internal t
Résumé du contenu de la page N° 19
FOR HVAC INSTALLER AND HOMEOWNER 6. Compressor terminal C and overload terminal 1: was not rotating. Contaminants are therefore largely confined No continuity indicates a defective overload lead. to the compressor housing. A single installation of liquid and 7. Overload terminals 1 and 3: suction line filter/driers will probably clean up the system. If If there is no continuity, the overload may be tripped. Wait sludge is evident in the discharge line, it will likely be found in 10 minutes
Résumé du contenu de la page N° 20
FOR HVAC INSTALLER AND HOMEOWNER point. It opens when the RH drops 4 to 6% below the set point. If the 7.9 Electric Ventilation Damper Ultra-Aire does not run, try turning the humidity control clockwise The electric ventilation damper is controlled by the ventilation timer. until it reaches the stop and the knob pointer points at “ON”. The damper will open when the ventilation timer is activated to allow fresh air into the structure through the 6" diameter fresh air The Ultra-Aire is equipp