Résumé du contenu de la page N° 1
REACH-IN
BEVERAGE
CASES
MODEL: ORB, ORBH,
ONRB & ONRBH
INSTALLATION & OPERATION
HANDBOOK
P057333G
Rev. 12 6/06
COMPONENT
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
2 Welcome to the ORIGIN display case family. We’re very pleased you joined us. This installation and operation handbook has been especially 2 prepared for everyone involved with ORIGIN display cases – owners, managers, installers and maintenance personnel. You’ll find this book different than traditional manuals. The most dramatic difference is the use of many more illustrated instructions to make it easier to read and to help you get the most from this innovative new design. When you follo
Résumé du contenu de la page N° 4
Résumé du contenu de la page N° 5
TABLE OF CONTENTS GENERAL INFORMATION – PAGES 3 - 8 General information, first step recommendations and case dimensional drawings. THE USE OF CASTERS – PAGE 9 Cases roll on casters–general use and caster removal. LINE-UP – PAGES 10 - 11 A twelve step procedure for initial case lineup with illustrations. TRIM-OUT – PAGES 12 - 13 A fifteen step procedure for trimming out cases with illustrations. REFRIGERATION PIPING – PAGE 14 Diagrams show coil outlet, case controls location, and other piping ti
Résumé du contenu de la page N° 6
2
Résumé du contenu de la page N° 7
GENERAL INFORMATION DESCRIPTION OF CASES: The refrigerated display cases described in this handbook 2 are part of the Hill PHOENIX, Origin design series. Specifically covered in this manual are models ORB reach-in beverage, ORBH high reach-in beverage, ONRB narrow reach-in bev- erage, & ONRBH high narrow reach-in beverage. STORE CONDITIONS: Hill PHOENIX cases are designed to operate in an air conditioned O O store with a system that can maintain 75 F (24 C) store temperature and 55 percent (max
Résumé du contenu de la page N° 8
GENERAL INFORMATION 41 7/16 in [105.2 cm] Amp plate & Serial Plate location 64 in [162.6 cm] (Frame Height) 59 in 81 1/4 in [149.9 cm] [206.3 cm] 62 3/8 in [158.4 cm] (Door Height) 83 1/4 in [211.5 cm] 1/2 BUMPER OPTION 30 7/8 in [78.4 cm] 7 1/2 in COIL PLENUM 16 1/16 in [19.1 cm] [40.9 cm] 6 13/16 in [17.2 cm]* 8 1/2 in 5 1/8 in 31 9/16 in [80.2 cm] [21.6 cm] [13.1 cm] 39 1/4 in [99.7 cm] 42 11/16 in [108.4 cm] MODEL PIPING-TO-TOP ORB (OPTIONAL) REAR REFRIGERATION WIRING-TO-TOP (13 15/16" off
Résumé du contenu de la page N° 9
41 7/16 in [105.2 cm] Amp plate & Serial Plate location 68 in [172.7 cm] (Frame Height) 63 in 85 1/16 in [160.1 cm] [216.0 cm] 66 3/8 in [168.6 cm] (Door Height) 87 1/16 in [221.1 cm] 1/2 BUMPER OPTION 30 7/8 in [78.4 cm] 7 1/2 in COIL PLENUM 16 1/16 in [19.1 cm] [40.9 cm] 8 1/2 in 6 13/16 in [17.2 cm]* 5 1/8 in [21.6 cm] [13.1 cm] 31 9/16 in [80.2 cm] 39 1/4 in [99.7 cm] 42 11/16 in [108.4 cm] MODEL PIPING-TO-TOP (OPTIONAL) ORBH REAR REFRIGERATION WIRING-TO-TOP (13 15/16" off of floor) (OPTION
Résumé du contenu de la page N° 10
GENERAL INFORMATION 34 5/8 in [88.0 cm] Amp plate & 64 in Serial Plate [162.6 cm] location (Frame Height) 62 3/8 in 59 in [158.4 cm] 81 1/4 in [149.9 cm] (Door Height) [206.4 cm] 83 1/4 in [211.5 cm] 23 1/4 in [59.1 cm] 1/2 BUMPER OPTION PLENUM 7 1/2 in COIL 16 1/4 in [19.1 cm] [41.3 cm] 8 in 6 13/16 in [17.3 cm]* 5 1/8 in [20.3 cm] [13.1 cm] 24 3/16 in [61.4 cm] MODEL 31 7/8 in [81.0 cm] 35 3/8 in [89.8 cm] ONRB PIPING-TO-TOP (OPTIONAL) REAR REFRIGERATION (12 1/4" off of floor) WIRING-TO-TOP 1
Résumé du contenu de la page N° 11
34 5/8 in [88.0 cm] Amp plate & Serial Plate 68 in [172.7 cm] location (Frame Height) 66 3/8 in 63 in [168.6 cm] 85 1/16 in [160.0 cm] (Door Height) [216.0 cm] 87 1/16 in [221.1 cm] 23 1/4 in 1/2 BUMPER OPTION [59.1 cm] PLENUM 7 1/2 in COIL 16 1/4 in [19.1 cm] [41.3 cm] 8 in 6 13/16 in [17.3 cm]* 5 1/8 in [20.3 cm] [13.1 cm] 24 3/16 in [61.4 cm] 31 7/8 in [81.0 cm] MODEL 35 3/8 in [89.8 cm] ONRBH PIPING-TO-TOP (OPTIONAL) REAR REFRIGERATION (12 1/4" off of floor) WIRING-TO-TOP 12 3/4 in [32.4 cm
Résumé du contenu de la page N° 12
GENERAL INFORMATION 4" 31 11/16" 23 3/16" 2 DOOR CASE STANDARD NARROW 59 1/4" FRONT OF CASE 4" 6" 4" 31 11/16" 23 3/16" 3 DOOR CASE STANDARD NARROW 8' CASE 47 1/2" (3dr CASE) 49 1/8" (8' CASE) 89 1/4" (3dr CASE) 95 1/4" (8' CASE) FRONT OF CASE 4" 6" 6" 4" 31 11/16" 23 3/16" STANDARD BASEHORSE NARROW 4 DOOR CASE LOCATION FOR MODEL 38 13/16" (4dr CASE) 44 5/8" (12' CASE) 77 3/16" (4dr CASE) ONRB, ONRBH, 92 5/8" (12' CASE) 119 1/4" (4dr CASE) ORB & ORBH 143 1/4" (12' CASE) FRONT OF CASE 6" 4" 4" 4
Résumé du contenu de la page N° 13
CASES MOVE ON CASTERS FOR EASIER INSTALLATION 2 ORIGIN cases are manufactured and shipped to Casters not only speed up the process, but they also stores with casters installed on the base frame to reduce the chance of damage from raising and low- ering cases with ”J” bar to place them on dollies, make the job of moving cases easier for everyone involved with the manufacturing, shipping and instal- skates or rollers. In most situations, one or two per- lation process. sons can move the case with
Résumé du contenu de la page N° 14
LINE UP BASE RAIL BASE RAIL Consult With General Contractor Snap Chalk Lines Snap Lines On Base Rail Locations Ask the general contractor if there Mark floor where cases are to be Snap lines where base rails are posi- have been changes in the building located for the entire lineup. tioned, not the front or back edges of dimensions since the print you are the cases. See case cross section using was issued. Also, ask the drawings, pages 4-8, for rail location points of reference from which you d
Résumé du contenu de la page N° 15
CAULK COTTER PIN LOCATION OUTRIGGER FOAM TAPE Remove Shipping Accessories Remove Outriggers Position Next Case In Line Up From Case. Add Sealant. Remove anything from the case that Remove cotter pin from outrigger by Roll case approximately 6’ from may interfere with case joining. Apply cutting tie strap. Either pull the out- adjoining case. Remove casters on the foam tape that is shipped loose in rigger out from the front or insert a the end nearest to the next case. the case to the end bre
Résumé du contenu de la page N° 16
TRIM OUT Now that cases have been positioned and leveled, you may proceed to trim-out case line- up. Trim parts have been designed to be applied easily with only a small number of fas- teners required. Most external parts are adjustable to achieve almost invisible, snug-fit- ting joints and a high level of excellence in fit and finish. BUMPER JOINT BUMPER SCREW Adjust polymer master bumper joints, Slide bumper joint to the center of the Slide master bumper left or right to if required. First
Résumé du contenu de la page N° 17
STREAMLYNE MASTER BUMPER COLOR EXTERNAL BAND BUMPER JOINT If the case has a Streamlyne front Insert exterior cornice joint at every Close joints on color band by sliding style the bumper may be shipped case joint. The exterior cornice joints the panels together. The color band loose in the case. Before installing are shipped loose with each case can be moved left or right as required bumper on the case install the exter- to allow adjustment. nal bumper joint on the Streamlyne bumper. Simply
Résumé du contenu de la page N° 18
REFRIGERATION PIPING Refrigeration components and the coil The expansion valve and other con- outlet hole are located to provide the best trols are located on the left-hand side of the access for installation and maintenance. As case, are accessible without lifting the fan the diagrams below indicates, the coil outlet plenum, and may be reached by lifting only hole is positioned forward on the right hand the left hand deck pan. side of the case, fully visible in front of the fan plenum. An opt
Résumé du contenu de la page N° 19
PLUMBING The drain outlet is located front and The kickplate is shipped loose with the center of the cases for convenient access and case for field installation, therefore you is especially molded out of ABS material. The should have open access to the drain line “P” trap, furnished with the case, is construct- area. ed of schedule 40 PVC pipe. Care should be given to assure that all connections are water If the kickplate has been installed, you tight and sealed with the appropriate PVC or wi
Résumé du contenu de la page N° 20
ELECTRICAL HOOKUP Electrical hookups are made to a For case-to-case wiring, run “greenfield”, junction box located at the bottom left or other conduit, between junction boxes. hand front of the case. At the owners When connecting to the junction box on the option the case made be wired to a junction bottom left side of the case, field wiring should box located on the top left rear of the case. exit the junction box from the right hand side, furthest away from case wiring, increasing room insi