Résumé du contenu de la page N° 1
D20
Installation Manual
WARNING: For your safety the information in AVERTISSEMENT: Assurez-vous de bien
this manual must be followed to minimize the suivre les instructions données dans cette notice
risk of fire or explosion or to prevent property pour réduire au minimum le risque d’incendie
damage, personal injury or death. ou d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
— Ne pas entreposer ni utiliser d’essence ni
— Do not store or use gasoline or other flamma
Résumé du contenu de la page N° 2
Retain This Manual In A Safe Place For Future Reference This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer. The following “FOR YOUR SAFETY” caution must be posted near the dryer i
Résumé du contenu de la page N° 3
IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. «Attention: Au moment de l’entretien des commandes, étiquetez tous les fils avant de “Caution: Label all wires prior to disconnection when servicing controls. Wiring les débrancher. Des err
Résumé du contenu de la page N° 4
WARNING The dryer must never be operated with the back guard removed. PERSONAL INJURY OR FIRE COULD RESULT. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer. Dryers must not be installed or stored in an area where it will be exposed to water or weather.
Résumé du contenu de la page N° 5
Table of Contents SECTION I IMPORTANT INFORMATION ............................................................................... 2 A. Receiving and Handling ............................................................................................................... 2 B. Safety Precautions ...................................................................................................................... 3 SECTION II SPECIFICATIONS ...........................................................
Résumé du contenu de la page N° 6
SECTION I IMPORTANT INFORMATION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves. Dryers damaged in shipment: 1. ALL dryers should be inspected upon receipt and b
Résumé du contenu de la page N° 7
B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with the back guard removed. PERSONAL INJURY OR FIRE COULD RESULT. 1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 2. Purchaser/user should consult the local gas supplier for proper i
Résumé du contenu de la page N° 8
WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a fire hazard. WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard. 7. A program should be established for the inspection and cleaning of lint in the exhaust ductwork and area around the back of the dryer. The frequency of inspection and cleani
Résumé du contenu de la page N° 9
SECTION II SPECIFICATIONS A. SPECIFICATIONS Ms AXIMUM CAPACITY (DRY WEIGHT) 20 lb 9 kg B” ASKET (TUMBLER) DIAMETER 25.75 65.4 cm B” ASKET (TUMBLER) DEPTH 24 60.95 cm BP ASKET (TUMBLER) MOTOR 1/4 H 0.19 kw BP LOWER MOTOR 1/8 H 0.1 kw B. ASKET (TUMBLER) VOLUME 7.5 cu.ft 0.21 cu.m. V” ENT CONNECTION 4 10.2 cm C” ABINET WIDTH 27 68.6 cm C” ABINET DEPTH 30 76.2 cm C” ABINET HEIGHT 41 104 cm Cs ABINET NET WEIGHT 237 lb 107.7 kg A0 IRFLOW5HZ 200 cfm 5.66 cmm A0 IRFLOW6HZ 240 cfm 6.79 cmm 120v/60 Hz/1ø
Résumé du contenu de la page N° 10
Specifications D20 NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 6
Résumé du contenu de la page N° 11
SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Pro
Résumé du contenu de la page N° 12
B. LOCATION REQUIREMENTS Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1- M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing). 1. The dryer must be installe
Résumé du contenu de la page N° 13
C. DRYER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 6-inches (15.24 cm) above the dryer’s outer top; except along the front of the dryer which may be closed if desired. NOTE: Allowances must be made for opening the control door. X = 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease of maintenance. NOTE: Air considerations are important for proper and efficient operation. Dryers may be positione
Résumé du contenu de la page N° 14
D. FRESH AIR SUPPLY REQUIREMENTS The D20 air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1/4 square feet (0.023 square meters) is required for each dryer. If registers or louvers are installed over the openings, then the area must be increased. It is not necessary to have a separate
Résumé du contenu de la page N° 15
E. EXHAUST REQUIREMENTS DO NOT use a nonmetal flexible vent or a metal vent that is smaller than 4” (10.2 cm) in diameter or exhaust hoods with magnetic latches. DO NOT exhaust dryer into a chimney, furnace, cold air vent, attic, crawl space, or any other vent used for venting. DO NOT install flexible vent in enclosed walls, ceilings, or floors. IMPORTANT: Observe ALL governing codes and ordinances. Exhaust your dryer to the outside. Moisture and lint indoors may cause: 1. Lint to gather aroun
Résumé du contenu de la page N° 16
12
Résumé du contenu de la page N° 17
IMPORTANT VENTING REMINDERS 1. Ductwork size and installation should be done by a qualified professional. 2. The dryer must be exhausted to the outdoors. 3. Ductwork should be routed as short as possible to the outdoors with as few elbows as possible. 4. Avoid 90° turns, use 30° or 45° turns instead. 5. The inside of the ductwork should be as smooth as possible with no projections from sheet metal screws. Ducts added should overlap the duct to which it is to be connected. 6. ALL ducts should be
Résumé du contenu de la page N° 18
F. ELECTRICAL INFORMATION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian E
Résumé du contenu de la page N° 19
2) Electric Models ONLY ALL electrically heated dryers must be connected to the electric service shown on the dryer’s data label, which is affixed to the upper left area of the inner back panel. The connecting wires must be properly sized to handle the rated current. NOTE: Electrically heated service (amperage) specifications/requirements are not available at the time of printing. Contact factory for update. NOTE: Component failure due to improper voltage application will VOID THE WARRANTY. 3
Résumé du contenu de la page N° 20
a. Gas Models Only 1) Single-Phase (1ø) Wiring Connections/Hookup If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer. 16