Résumé du contenu de la page N° 1
CLOTHES DRYER
Technical Information
IMPORTANT SAFETY NOTICE – “For Technicians only” This service data sheet is intended for
use by persons having electrical, electronic, and mechanical experience and knowledge at a level
generally considered acceptable in the appliance repair trade. Any attempt to repair a major
appliance may result in personal injury and property damage. The manufacturer or seller cannot
be responsible, nor assume any liability for injury or damage of any kind arising from
Résumé du contenu de la page N° 2
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. ERROR ITEMS AND DIAGNOSTIC CODES An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors. Error Display Trigger Action Taken Check for: The Termistor resistance is - Clogged lint screen. tE very low or high. - Restricted vent system. - Ch
Résumé du contenu de la page N° 3
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TEST MODE Service Mode (DV405, DV398, DV395, DV393 only) How to enter: - To enter Service Mode , press Mixed Load Bell + Temp. Keys 3 seconds in normal mode until it sends out a beeping sound. - If pressing Mixed Load Bell + Temp. Keys in Service mode , it will return Normal mode. - Even though entering Service mode, the opera
Résumé du contenu de la page N° 4
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Continuous Run Mode Power On state Mixed Load Bell +Dry Level(DV405, DV398, DV395, DV393) Continuous Run Mode (Normal user mode) or Wrinkle Prevent + Time(DV231, DV365) 7 SEC How to enter: - Press Mixed Load Bell +Dry Level(DV405, DV398, DV395, DV393) or Wrinkle Prevent + Time(DV231, DV365) for 7 sec during Power On State (nor
Résumé du contenu de la page N° 5
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TROUBLE DIAGNOSIS - As the micom dry machine is configured of the complicate structure, there might be the service call. Below information is prepared for exact trouble diagnosis and suitable repair guide. Caution for the Repair and Replacement Please follow below instruction for the trouble diagnosis and parts replacement.
Résumé du contenu de la page N° 6
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. No Problem What To Do • All wires are hooked up to their corresponding terminals. • Dryer is plugged in. • Blown fuse or circuit breaker. • Door switch functional...door closed. Check for error code 3 (See Table for codedefinition). 1 Will Not Start or Run • Start/Pause rotary selector dial functional. • Control Board operational. • Be
Résumé du contenu de la page N° 7
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. No Problem What To Do If the igniter does not heat up, remove power and using an ohmmeter, check the following: • Open flame sensor The igniter does not • Open igniter 8 glow • Shorted booster coil • Open wiring • Bad motor switch ( Neutral supply) • No power from control ( L1 supply) If the igniter heats up but the main burner flame i
Résumé du contenu de la page N° 8
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. COMPONENT TESTING PROCEDURES Component Electrical Testing (with ohmmeter) Belt Cut-off S/W - Lever open: Resistance value < 1Ω Thermistor resistance 10K Ω @ 25°C 77°F - Lever push: Resistance value : ∞ Ω Thermostat 1 resistance < 1Ω Thermostat 3 resistance < 1Ω Lamp resistance 80~100 Ω (Violet & gray) - If resistance is inf
Résumé du contenu de la page N° 9
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. THERMISTOR 238.23Ω @ 25 °C 77 GAS MODEL Radiant Sensor(10RS) Gas Valve(25M01A) Resistance value < 1 Ω Valve 1-2 : Resistance value 1.2K Ω If resistance is infinite, replace Radiant sensor Valve 1-3 : Resistance value 0.5K Ω Valve 4-5 : Resistance value 1.2K Ω If resistance is infinity, replace Valve Igniter(101D) Resistance value 40~40
Résumé du contenu de la page N° 10
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Sensor Bars & temperature sensor check Sensor Bars - Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5. Approx ∞ Ω without laundry Approx 190Ω ± 10% with wet clothes Cycling Thermistor - Disconnect harness and test Blue wire Pin 3 to Red wire Pin 6. Approx 10 KΩ at 25 °C/77 °F Sensor Bars & temperature sensor check (DV3
Résumé du contenu de la page N° 11
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. 3-WIRE system connections A. External ground connector B. Neutral grounding wire (green/yellow) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. ¾” (1.9 cm) UL-listed strain relief 1. Loosen or remove the center terminal block screw. 2. Connect the neutral wire (white or center wire) of the power
Résumé du contenu de la page N° 12
WIRING DIAGRAM WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. WIRING DIAGRAM OPTION 1 : Steam Models Only, OPTION 3 : DR READY Models Only 12 (Technical)DV405-02365H-03_EN_130221.indd 12 2013-02-21 �� 5:32:03
Résumé du contenu de la page N° 13
WIRING DIAGRAM WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. WIRING DIAGRAM (DV398 ONLY) 13 (Technical)DV405-02365H-03_EN_130221.indd 13 2013-02-21 �� 5:32:04
Résumé du contenu de la page N° 14
MEMO 14 (Technical)DV405-02365H-03_EN_130221.indd 14 2013-02-21 �� 5:32:04
Résumé du contenu de la page N° 15
SECADORA Información técnica AVISDO DE SEGURIDAD IMPORTANTE – “Sólo para técnicos” Esta hoja de datos de servicio está destinada a personas que tengan experiencia eléctrica, electrónica y mecánica, así como conocimientos generales considerados aceptables en el servicio de reparación de aparatos. Cualquier intento de hacer reparaciones importantes podría causar lesiones físicas o daños materiales. Ni el fabricante ni el vendedor se hacen responsables, ni asumen ninguna obligación legal por l
Résumé du contenu de la page N° 16
ALINEACIÓN Y AJUSTES ADVERTENCIA Para evitar riesgos de descarga eléctrica, lesiones o la muerte, desconecte el cable de alimentación de la secadora a menos que la prueba del electrodoméstico requiera que este esté enchufado. CÓDIGOS DE ERROR Y DE DIAGNÓSTICO Cuando ocurre un error suena una melodía durante 5 segundos y en la pantalla se muestra uno de los errores siguientes. Error mostrado Descripción Acción correctiva Verifique: La resistencia del termistor es - Filtro para pelusas obstruido
Résumé du contenu de la page N° 17
ALINEACIÓN Y AJUSTES ADVERTENCIA Para evitar riesgos de descarga eléctrica, lesiones o la muerte, desconecte el cable de alimentación de la secadora a menos que la prueba del electrodoméstico requiera que este esté enchufado. MODO DE PRUEBA Modo de servicio (DV405, DV398, DV395, DV393 solamente) Cómo ingresar: - Para ingresar al Modo de servicio, presione las teclas Mixed Load Bell (Timbre de carga mixta) + Temp (Temperatura) durante 3 segundos en el modo normal hasta que oiga un pitido. - Si
Résumé du contenu de la page N° 18
ALINEACIÓN Y AJUSTES ADVERTENCIA Para evitar riesgos de descarga eléctrica, lesiones o la muerte, desconecte el cable de alimentación de la secadora a menos que la prueba del electrodoméstico requiera que este esté enchufado. Modo de ejecución continua Power On state Mixed Load Bell +Dry Level(DV405, DV398, DV395, DV393) Continuous Run Mode (Normal user mode) or Wrinkle Prevent + Time(DV231, DV365) 7 SEC Cómo ingresar: - Presione Mixed Load Bell (Timbre de carga mixta) + Dry Level (Nivel de sec
Résumé du contenu de la page N° 19
ALINEACIÓN Y AJUSTES ADVERTENCIA Para evitar riesgos de descarga eléctrica, lesiones o la muerte, desconecte el cable de alimentación de la secadora a menos que la prueba del electrodoméstico requiera que este esté enchufado. DIAGNÓSTICO DE PROBLEMAS - Puesto que la estructura de la secadora micom es compleja, puede ser necesario contactar al servicio técnico. La siguiente información está elaborada para el diagnóstico exacto de los problemas y a modo de guía de reparación. Siga las siguie
Résumé du contenu de la page N° 20
SOLUCIÓN DE PROBLEMAS ADVERTENCIA Para evitar riesgos de descarga eléctrica, lesiones o la muerte, desconecte el cable de alimentación de la secadora a menos que la prueba del electrodoméstico requiera que este esté enchufado. No Problema Solución • Todos los cables están conectados en sus terminales correspondientes. • La secadora está enchufada. • Fusible quemado o disyuntor dañado. • Interruptor puerta funcional...puerta cerrada. Verifique código de error 3 (Consulte la tabla de definición