Résumé du contenu de la page N° 1
Owner's Manual
Includes the SIA CP-01 Control Panel Standard
Features for False Alarm Reduction
Document Number 21R00-1 Rev. 2.13
September, 2006
Résumé du contenu de la page N° 2
Document Number 21R00-1 Rev. 2.13 September, 2006 Copyright © 2000-2006 HAI All Rights Reserved www.homeauto.com
Résumé du contenu de la page N° 3
Contents INTRODUCTION........................................................................................................................................... 1 Underwriter's Laboratories (UL) Listing .........................................................................................................................................1 OVERALL DESCRIPTION.......................................................................................................................... 2 Console
Résumé du contenu de la page N° 4
CONTROL .................................................................................................................................................... 15 About UPB.....................................................................................................................................................................................15 HAI Lighting Control (HLC) Format..............................................................................................................
Résumé du contenu de la page N° 5
Status..............................................................................................................................................................................................33 Configuring HLC Devices ........................................................................................................................................................34 Configuring HLC Devices using an Omni Console.........................................................................
Résumé du contenu de la page N° 6
Alarm Event Buttons.................................................................................................................................................................54 X-10 Event Buttons...................................................................................................................................................................54 Miscellaneous Event Buttons......................................................................................................
Résumé du contenu de la page N° 7
UNDERWRITER'S LABORATORIES REQUIREMENTS ................................................................... 71 FEDERAL COMMUNICATION COMMISSION NOTICE: ................................................................. 72 CANADIAN INDUSTRY CANADA NOTICE.......................................................................................... 73 APPENDIX A - SPECIFICATIONS........................................................................................................... 74 APPENDIX B
Résumé du contenu de la page N° 8
Résumé du contenu de la page N° 9
INTRODUCTION Thank you for purchasing your new OmniLT automation system. You are about to experience a new feeling of comfort, convenience, and control. Please take a few moments to become familiar with all of the features of this fine product by reviewing this manual. Please keep this manual on file for future reference. It is recommended that you also review the installation and operating instructions provided with your smoke and gas detectors (if used in your system). If you
Résumé du contenu de la page N° 10
OVERALL DESCRIPTION Console Operation The console is designed with everything that is necessary for you to program and operate your OmniLT control and security system. Because we feel that it is very important for you to feel comfortable with the operation of your OmniLT, we recommend that you start by becoming familiar with your console. The OFF (1), DAY (2), NIGHT (3), and AWAY (4) keys are called shortcut keys. This means that you may press these keys to go directly to that fu
Résumé du contenu de la page N° 11
6- UP ARROW The Up Arrow key is used to scroll through menus and lists. The Up Arrow is used to scroll back through a list (for example, if you have already used the down arrow to scroll to an item, the Up Arrow will bring you back to a previous item). 7- CONSOLE LED The Console LED is used to indicate whether the security system is currently armed or disarmed. If armed in any of the security modes, the LED will be set to red. If the system is disarmed, the LED will be set to gre
Résumé du contenu de la page N° 12
When using the arrow keys to scroll through lists of units, zones, buttons, codes, and temperature zones, only the named items are displayed. If no text description has been given to an item, it will be skipped over when scrolling through that list. You can still enter any item number to access it directly, and then scroll up and down among the named items. To look at another specific item, simply enter the item number followed by the Down Arrow key. In some cases, the keypad keys (0
Résumé du contenu de la page N° 13
Confirmation Beep When you have successfully completed a function, such as entering a program or changing a setup item, the console will beep once. Cancel If you are ever unsure and wish to return to the top-level display, press the ' * ' key. You may have to press it more than once, depending on how far into the function (menu) you are. Each time you cancel out of an operation, the console will beep once to indicate that you have canceled. The ' * ' key can also be used if yo
Résumé du contenu de la page N° 14
SECURITY SYSTEM OPERATION Disarming the Security System and Silencing Alarms Before going any further, you should know how to disarm your security system in the event that the alarm sounds. Turning the system OFF disarms the burglar alarm, resets emergency alarms, and silences all sirens and sounders. Press the OFF key. OFF Watch the display. The top line will read "DISARM" - The bottom line will read "ENTER CODE", indicating that you must enter your code number to disarm
Résumé du contenu de la page N° 15
2 = NIGHT The NIGHT mode is used when you are asleep and everyone in your household is at home. In the Night mode, your doors, windows, and non-sleeping area (i.e. downstairs) motion detectors are armed. In the Night mode, there is no entry delay. The alarm system sounder will be activated immediately if any door, window, or non-sleeping area (motion detector) is tripped. 3 = AWAY Use the AWAY mode when you leave your house and no one is home. All doors, windows, and motion det
Résumé du contenu de la page N° 16
What Happens When You Arm the Security System To arm the system into one of the 6 security modes, from the security menu, choose the security mode and press the appropriate key (1 - 6), and then enter your user code number on the console keypad or use one of the Shortcut Keys as described. The console will beep once and the console LED will be set to red The controller will cycle power to reset smoke detectors The top line will display the security mode. The bottom line w
Résumé du contenu de la page N° 17
Bypassing Zones 8 = BYPASS You can Bypass a zone that you do not want protected while the system is armed. Bypassing is also the only way that a tamper or panic zone can be disarmed. For example, if there is a liquor closet or gun case on a tamper zone, then you must bypass that zone to gain access to it. Another reason to Bypass a zone is if the zone is having trouble. If a zone is causing a trouble indication, you can bypass that zone to "cut it out" of the system until repair
Résumé du contenu de la page N° 18
What To Do When You Come Home If you enter your home while the system is armed in the Day, Night Delay, Away, or Vacation mode using an entry door: • The console beeper comes on and beeps 4 times per second. • The console display indicates: " *** DISARM SYSTEM *** - PRESS OFF THEN CODE" • Any lights or control modules programmed to come on for the door that you used will do so. • The system will wait the Entry Delay time. You should go to your console and immediately disarm
Résumé du contenu de la page N° 19
Fire Alarm Activated When the fire alarm is activated by the smoke/fire detector(s), the alarm responds exactly as described under Burglar Alarm Activated, except: • The console display reads, "FIRE ALARM! ZONE NAME TRIPPED". • The sounder will activate in a 3 pulse temporal pattern to distinguish the fire alarm from the burglar alarm. The fire alarm takes priority over the burglar alarm, however, if a gas alarm is already active, it will not override the gas alarm. NOTES:
Résumé du contenu de la page N° 20
Police Emergency When the 1 key and the 3 key is pressed simultaneously, the Police Emergency alarm is activated. This alarm operates exactly the same as described for Burglar Alarm Activated except: • The console display indicates: "BURGLARY! - POLICE EMERG TRIPPED". Fire Emergency When the 4 key and the 6 key is pressed simultaneously, the Fire Emergency alarm is activated. This alarm operates exactly the same as described for Police Emergency Button except: • The sounde