Résumé du contenu de la page N° 1
ENGLISH ESPAÑOL
website http://www.lgservice.com
e-mail http://www.lgeservice.com/techsup.html
LG
LG
Window-Type Air Conditioner
OWNER'S MANUAL
MODELS, MODELOS: LWHD1000CR
IMPORTANT
Please read through this manual. It contains valuable
information about your air conditioner.This manual may
help save time and money by explaining proper air
conditioner maintenance and preventing improper use.
PRECAUTIONS
Pay close attention to precautions in order to prevent
potential hazards and damage from misu
Résumé du contenu de la page N° 2
Window-Type Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS Safety Precautions..........................3 Write the model and serial numbers here: Model # Prior to Operation ...........................7 Serial # You can find them on a label on the side of each unit. Dealer's Name Introduction .....................................8 Date Purchased Staple your receipt to this page in the event you need it Electrical Safety .............................9 to prove date of purchase
Résumé du contenu de la page N° 3
ENGLISH Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. Meanings of symbols used in this manual are as shown belo
Résumé du contenu de la page N° 4
Safety Precautions Operation Do not place heavy object Do not share the outlet with Take the power plug out if on the power cord and take other appliances. necessary, holding the head care so that the cord should of the plug and do not touch not be pressed. it with wet hands. • There is danger of fire or • It will cause electric shock or • Otherwise, it may cause a electric shock. fire due to heat generation. fire or electrical shock. Do not place the power cord Do not allow water to run Us
Résumé du contenu de la page N° 5
ENGLISH Safety Precautions Do not operate or stop the Do not damage or use an Do not operate with wet unit by inserting or pulling unspecified power cord. hands or in damp out the power plug. environment. • It will cause electric shock or • It will cause electric shock or • It will cause electric shock. fire due to heat generation. fire. Hold the plug by the head When gas leaks, open the Never touch the metal parts when taking it out. window for ventilation of the unit when removing before ope
Résumé du contenu de la page N° 6
Safety Precautions Operation Do not put a pet or house Do not block the inlet or Use a soft cloth to clean. Do plant where it will be outlet of air flow. not use wax, thinner, or a exposed to direct air flow. strong detergent. • It may cause injury. • It may cause product failure. • The appearance of the air conditioner may deteriorate, change color, or develop surface flaws. Do not step on the Always insert the filter Do not drink water drained indoor/outdoor unit and do securely. fr
Résumé du contenu de la page N° 7
ENGLISH Prior to Operation Prior to Operation Preparing for Operation 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Use a dedicated circuit. 4. Do not use an extension cord. 5. Do not start/stop operation by plugging/unplugging the power cord. 6. If the cord/plug is damaged, replace it with only an authorized replacement part. Usage 1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose o
Résumé du contenu de la page N° 8
°C °C Introduction Introduction Symbols Used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. NOTICE This symbol indicates special notes. Features This appliance should be installed in accordance with the National Electric Code. CABINET SIDE LOUVER FRONT GRILLE VERTICAL AIR DEFLECTOR AIR FILTER (HORIZONTAL LOUVER) AIR INTAKE AIR DISCHARGE (INLET GRILLE) BRACE CONTROL BOARD COMPRESSOR EVAPORATOR
Résumé du contenu de la page N° 9
ENGLISH Electrical Safety Electrical Safety Electrical Data 115V~ 230V~ Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. NOTICE The shape may be different accor
Résumé du contenu de la page N° 10
Electrical Safety Electrical Safety A. SITUATIONS WHEN THE APPLIANCE WILL BE IMPORTANT DISCONNECTED OCCASIONALLY: (PLEASE READ CAREFULLY) Because of potential safety hazards, we strongly FOR THE USER'S PERSONAL SAFETY, THIS discourage the use of an adapter plug. However, if you APPLIANCE MUST BE PROPERLY GROUNDED wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, The power cord of this appliance is equipped with a available from most local hardware stores.
Résumé du contenu de la page N° 11
ENGLISH Installation Installation Installation Kits Contents 8 9 10 15 16 17 NO. NAME OF PARTS QTY 1 Curtain 1 2 Curtain Frame 1 2 3 Upper Guide 1 4 Side Guide 2 12 5 Support Bracket 1 6Bracket 1 4 11 7 Leveling Bolt & Nut 1 1 8 Bolt 2 3 9 Nut 2 10 Washer 2 11 Side Guide seal 1 13 12 Foam Seal Strip 1 5 13 Window Track Seal 1 6 14 14 Window Locking Bracket 1 7 15 Screw (Type A) 9 16 Screw (Type B) 3 17 Screw (Type C) 8 Window Requirements 1. These instructions are for a horizontal sliding For
Résumé du contenu de la page N° 12
°C °C Installation How to Install the Unit 1. To prevent vibration and noise, make sure the unit is installed securely and firmly Awning Fence 2. Install the unit where the sunlight does not Cooled air shine directly on the unit. Heat radiation 3. The outside of the cabinet must extend outward for at least 14" and there should be no obstacles, such as a fence or wall, within 20" 1 About /4" from the back of the cabinet because it will Over 20" prevent heat radiation of the condenser. Rest
Résumé du contenu de la page N° 13
ENGLISH Outside Wall °C Installation Horizontal Sliding Window Installation 1. Loosely attach the Support Bracket to the Bolt bottom of Bracket using Bolts, Washer, and Bracket Nuts. Attach the Leveling Bolt and Nut. (Fig. 1) Washer Nut Leveling Bolt & Nut Support Bracket 2. Remove protective backing from Window Track Seal and apply seal to window track. Fig. 1 (Fig.2) Windo Windo Window J w Jamb amb amb T Type C scre ype C screw w 3. Measure and lightly mark a line 8-1/4 inches 1 1 from windo
Résumé du contenu de la page N° 14
°C Installation 7. Measure height of window opening from top of Bracket assembly as shown Fig. 5. Subtract 20-3/4 inches. Mark this measurement on Curtain and cut the Curtain. (Fig. 5) Fig. 5 8. Slide Curtain into Curtain Frame. Slide Curtain Frame assembly into side Guides of the Air Conditioner cabinet. Make sure Frame Curtain Curtain is firmly enclosed on all sides by the Frame. (Fig. 6) Curtain Fig. 6 9. Cut side Guide seal into 2 equal lengths. Remove protective backing and apply it t
Résumé du contenu de la page N° 15
ENGLISH °C Installation NOTICE Foam seal strip Check all seals and plug any remaining air gaps with a suitable weatherproof caulk. 14. If this is a casement window installation, proceed to Casement Window Installation. If not, stuff the Foam Seal Strip between the vertical sash and the window glass. (Fig. 9) Window locking bracket 15. Attach the L Bracket with a Type B screw. (Fig. 9) Fig. 9 Casement Window Installation 1. Installation procedure is the same as that described in steps 1 through
Résumé du contenu de la page N° 16
Operating Instructions Operating Instructions Controls The remote control and control panel will look like those represented in the following pictures. 6 3 1 Power 1 Temp 2 Fan Speed 4 Timer Mode 5 3 2 45 Remote Control Operations 1. POWER 4. FAN SPEED • To turn the air conditioner ON, push this button. • Every time you push this button, it advances the To turn the air conditioner OFF, push the button setting as follows: {High(F3) Low(F1) again. Med(F2) High(F3)} • This button takes prio
Résumé du contenu de la page N° 17
ENGLISH Operating Instructions Inserting the Remote Control Batteries 1. Push out the cover on the back of the remote control with your thumb. 2. Pay attention to polarity and insert two new AAA 1.5V batteries. 3. Reattach the cover. NOTICE Do not use rechargeable batteries. Make sure that both batteries are new. Do not mix alkaline, standard(Carbon-zinc) or rechargeable(Nickel- cadmium) batteries. • In order to prevent discharge, remove the batteries from the remote control if the air conditi
Résumé du contenu de la page N° 18
°C °C Operating Instructions Additional Features Additional controls and important information. Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. When the damper is opened and room air is exchanged with external air. CLOSE VENT OPEN Air Direction The direction of air can be controlled wherever you want to cool by adjusting the horizontal louv
Résumé du contenu de la page N° 19
ENGLISH °C °C Maintenance and Service Maintenance and Service TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. Air Filter Cleaning The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. To remove: 1. Open the inlet grille downward by pulling out the top of the inlet grille. 2. Remove the air filter from the front grille assembly by pulling the air filter up slightly. 3. Clean the filter with warm, soap
Résumé du contenu de la page N° 20
Maintenance and Service Common Problems and Solutions Before calling for service If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer. Air conditioner does not operate 1. Ensure that the air conditioner is plugged into a proper outlet. 2. Check the fuse or circuit breaker. 3. Check whether the voltage is unusually high or low. Air does not feel cold enoug