ATD-5956
3000 WATT INVERTER
Welcome.
This ATD product has been carefully engineered and manufactured to give
you dependable operation. Please read this manual thoroughly before operating your new ATD
product, as it contains the information you need to become familiar with its features and obtain
the performance that will bring you continued enjoyment for many years. Please keep this
manual on file for future reference.
About ATD Inverters.
ATD, an innovator in portable inverter
Résumé du contenu de la page N° 2
Multiply: AMPS X 110 (AC voltage) = WATTS This formula yields a close approximation of the continuous load of your appliance Multiply: WATTS X 2 = Starting Load This formula yields a close approximation of the starting load of your appliance. Most often the start up load of the appliance or power tool determines whether your inverter has the capability to power it. To determine whether the inverter will operate a particular piece of equipment or appliance, run a test. The inverters
Résumé du contenu de la page N° 3
A. ON/OFF Switch. The current flowing from the power source to the inverter is controlled by this switch. B. ON/OFF and protect LED Indicator Light. GREEN will illuminate when turn the inverter ON at normal condition. When the internal operating temperature exceeds 165 °F. this light will turn RED and the inverter will automatically shut down. Immediately turn off the appliance if this occurs The High Speed Cooling Fan automatically activates excessive temperatures are detected. When thi
Résumé du contenu de la page N° 4
Selecting A Power Supply. When you operate the inverter for long periods of time combined with a high continuous load demand, the result will be a large power drain from the battery. With this in mind, check the reserve capacity of the battery you plan to use to power your inverter. To calculate the approximate power drain on your battery you will want to estimate the reserve power ("amp/hour") of the battery and the amps the inverter will require, to meet the continuous load demand of the
Résumé du contenu de la page N° 5
Connecting Your inverter. 1. Make sure the ON/OFF switch located on the front panel of the inverter is in the OFF(0) position. 2. Connect the cables to the power input terminals at the rear of the Inverter. Make sure to match the negative (Black) terminal on the 12-volt power source first. Then repeat this procedure with the positive (Red) terminal connecting a wire to the positive terminal of the 12V volt power source. Make sure you have good secure connections, but do not over tighten t
Résumé du contenu de la page N° 6
Television and Audio Suggestions Although these inverters are shielded and filtered to minimize signal interference, some interference with your television picture may be unavoidable, especially with weak signals. However, here are some suggestions that may improve reception. 1. First, make sure that television antenna produces a clear signal under normal operating conditions. Also, ensure that the antenna cable is properly shielded and of good quality. 2. Change the positions of the inver
Résumé du contenu de la page N° 7
How Power Inverters Work. There are two stages in which a power inverter changes the 12 volt DC (or battery) power into 110V AC (household current). STAGE 1: The inverter uses a DC to DC converter to increase the DC input voltage from the power source to 145 volts DC. STAGE 2: The inverter then converts the high voltage DC into 110V AC (household current), using advanced MOSFET (Metal-Oxide-Semiconductor Field Effect Transistor) transistors in a full bridge configuration. This design
Résumé du contenu de la page N° 8
When operating the inverter with an automobile or marine battery, start the engine every 30 to 60 minutes and let it run for approximately 20 minutes to recharge the battery. In the event of a continuous audible alarm or automatic shut down, turn the inverter OFF immediately. Do not restart the inverter until the source of the problem has been identified and corrected. To avoid battery drain, always disconnect the inverter when not in use. Do not expose the inverter to rain or moisture
Résumé du contenu de la page N° 9
Troubleshooting PROBLEM: Low or No Output Voltage Reason: Poor contact with lighter socket or battery clamps Solution: Unplug and reinsert 12 volt plug or reattach battery clamps. Reason: Using incorrect type of voltmeter to test output voltage. Solution: Use true RMS reading meter.
Résumé du contenu de la page N° 10
PROBLEM: TV Does Not Work Reason: TV does not turn on. Solution: Try turning the inverter ON/OFF/ON. Contact TV manufacturer for start up surge specifications and/or to see if the TV is compatible with a modified sine wave. A larger inverter may be required. SPECIFICATION: Max. Continuous Power..............