Résumé du contenu de la page N° 1
Installation and Operating Instructions
®
Zenith HydroTap
Filtered boiling and chilled drinking water for kitchens and tea rooms.
Commercial Models
37671 Zenith HydroTap BC60/85
30271 Zenith HydroTap BC100/125
30281 Zenith HydroTap BC150/175
37201 Zenith HydroTap B10OF
38201 Zenith HydroTap B150F
37691 Zenith HydroTap B60
37291 Zenith HydroTap B100
Domestic models
38291 Zenith HydroTap B150
30009 Zenith HydroTap HT60
Disabled Models
30609 Zenith HydroTap HTD60
37676 Zenith HydroTap BCD60/85
Résumé du contenu de la page N° 2
Contents Read These Warnings First . . . . . . . . . . . . . . . . . . . . . . . . . .3 Models covered by these instructions . . . . . . . . . . . . . . . . . .4 Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Special tools required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Step A - Installing the tap (all models) . . . . . . . . . . . .5 Step B - Installing the
Résumé du contenu de la page N° 3
Read These Warnings First Safety Do not allow young children, handicapped or infirm persons, to use the Zenith HydroTap without supervision. Refrigerant The Zenith HydroTap Chilling unit contains 134A refrigerant under pressure. No part of the unit should be exposed to a naked flame. Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration mechanic. Qualifications If any power cord or plug is damaged it must be repaired only by a qual
Résumé du contenu de la page N° 4
# # Section Heading Section Heading Read These Warnings First continued Frost Protection If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework and fittings. Installation Environment Considerations This unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature. Th
Résumé du contenu de la page N° 5
Installation Requirements continued This switch must provide all-pole disconnection and a contact separation of at least 3mm installed in accordance with wiring rules. Cold water supply with a minimum working pressure of 175 kPa and a maximum working pressure of 700 kPa connected via an isolation valve. If pressure is likely to exceed 700 kPa, install a 500 kPa Pressure Limiting Valve. The fitting of an air flow vent cut into the top half of the cupboard door concealing the HydroTap requir
Résumé du contenu de la page N° 6
Installation procedure continued Step B - Installing the undersink unit (all models) SPECIAL NOTE: The HydroTap undersink units are heavy, take note of the weights listed in the table on page 4. If you think you cannot lift the unit safely, get help and avoid possible injury. Before positioning the heater connect the braided water inlet hose (supplied) to the cold water inlet on the unit. This is located at the rear of the unit. Position the Zenith HydroTap undersink unit as close as possible to
Résumé du contenu de la page N° 7
Installation procedure continued Step D - Connecting the water supply (all models) To prevent sediment from entering the Zenith HydroTap at connection, flush water through the supply line thoroughly before connection to the Zenith HydroTap. Open the access door and check that the filter is in place and secure. Connect the water supply to the undersink unit using the attached flexible hose. Turn on water and check for leaks. If no leaks are evident turn the poer on. Step E - Testing and commissi
Résumé du contenu de la page N° 8
Font installation procedure 1. Position the Font template (provided) on the bench area. Ensure the position you select is within the length of the supply tube and USB cable fixed to the Tap Head Assembly. These cannot be extended. 2. Check again for correct positioning. The supply hoses must have constant fall back to the tank assembly. Cut the holes as shown on the template. 3. Once holes are cut, locate the Font base in position, from the underside, lightly tighten the securing rod with the
Résumé du contenu de la page N° 9
Operating the Tap Blue Chilled Water Light On all the time: This indicates that the chilled water temperature is within the usable range. Flashing slowly : This indicates that the chilled water is not at the right temperature. Wait up to 20 minutes.When the chilled water is ready, the light will stop flashing. Note: The Zenith HydroTap is designed to dispense chilled water in the temperature range 5°C to 10°C. During heavy usage, the temperature can rise out of this range. Red Boiling Water L
Résumé du contenu de la page N° 10
Cleaning Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft cloth or brush and mild soap and water. Do not spray water over the tap as it may damage the low-voltage electronics. Undersink units must never be cleaned with water jets. Replacing the Filter (filtered models only) The Zenith HydroTap notifies the user when filter replacement is due. The default seting is 6000L. When a filter change is due, the Change Filter light flashes once a minute and remains so until r
Résumé du contenu de la page N° 11
Setting the Energy Saver Timer (products with this feature only) Plus Adjust Button Mode Plus Button Minus Adjust Button Mode Minus Button Normal Operation (not available on HT boiling only series) Set Time To change time, press either Mode ∧ or Mode ∨ button until Set Time is on the display screen. Press ∧ Adjust button to increase time or ∨ Adjust button to decrease time. Time increases or decreases in increments of one minute. Hold the Adjust buttons down for rapid increases or decreases. S
Résumé du contenu de la page N° 12
Auxiliary Fan Attachment (excluding HT boiling only models) Auxiliary fan The HydroTap is equipped with an auxiliary connection point for an exhaust fan connection on the rear panel close to the cold water inlet / flex and plug area. The fan kit is available as a spare part. The fan operates in parallel with the Condensor Cold water fan helping to remove heat from the cupboard space. This fan should be connection purchased and fitted to the HydroTap if the airfow characteristics of the Electric
Résumé du contenu de la page N° 13
Trouble Shooting Symptom Possible Cause Solution No LED display, no tap head No power. Check power supply. lights or, no water when tap Plug is not located in power Ensure power plug is correctly fitted and switch is levers are operated. socket. turned ON. Tap loom is not connected to Check loom connection. HydroTap unit. Possible internal fault. Contact local Zenith service provider. Program in OFF cycle Check LCD for information. No water flow. Water supply isolated. Check water supply is on.
Résumé du contenu de la page N° 14
Exploded View Chiller Module and Spare Parts Item Kit No. Description Item Kit No. Description 1 Z90613 plumbing fittings kit 14 Z90056 braided hose 2 Z90614 safety solenoid kit 15 Z90635 level sensor kit cold tank BC100/125 3 Z90615 double solenoid kit 15 Z90627 level sensor it BC150/175 4 Z90631 gasket and elbows kit cold tank 16 Z90636 relay compressor kit BC100/125 5 Z90626 dryer-filter kit nut and tube 16 Z90024 relay compressor kit BC150/175 6 Z90632 evaporator kit BC100/125 17 Z90637 com
Résumé du contenu de la page N° 15
Exploded View Boiler Module and Spare Parts Item Kit No. Description Item Kit No. Description 1 Z90613 plumbing and fittings kit 13 Z90130 clips kit 2 Z90614 safety solenoid kit 14 Z90628 stop valve and john guess fittings kit for filter 3 Z90615 double solenoid kit 15 Z90056 braided hose inlet 4 Z90616 gasket and elbow kit BC 100/125 16 Z90629 level sensor kit hot tank BC100/125 4 Z90617 gasket and elbow kit BC 150/175 16 Z90630 level sensor kit hot tank BC150/175 5 Z90579 overload kit 17 Z9018
Résumé du contenu de la page N° 16
Exploded View HT Series Boiling Only and Spare Parts ITEM KIT NO. DESCRIPTION 1 Z90656 Plumbing and Fittings kit 2 Z90614 Safety Solenoid Kit 3 Z90657 Single Solenoid Kit 4 Z90658 Gasket and Elbow Kit BC 100/125 5 Z90579 Overload Kit 6 Z90618 Element 1500 watt Kit 7 Z90620 Sensor Probe Hot 8 Z90621 Pump Kit Hot 9 Z90689 PCB Kit Boiling Only 10 Z90624 Leak Sensor Kit 11 Z90130 Clips Kit 12 Z90056 Flexible Inlet Hose Kit 13 Z90690 Level Sensor Kit Hot Tank H/T 60/85 14 Z90186 Loom-Overload Kit 15
Résumé du contenu de la page N° 17
Notes Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Page 17 of 20
Résumé du contenu de la page N° 18
Notes Page 18 of 20 Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005
Résumé du contenu de la page N° 19
Notes Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Page 19 of 20
Résumé du contenu de la page N° 20
# Warranty Information The Zenith appliance you have chosen is precision-built from the finest materials available and should give many years of trouble free service. Certain warranties may be implied by law into your contract with Zenith. The warranty provided below is additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law. Parex Appliances warrants that, should any part fail within 12 calendar months of installation, that part will b