Résumé du contenu de la page N° 1
Monitored Dual Filtration System
Installation and Operating Instructions
Model US-1500 (with electronic monitor)
NOTE:
Specifications
• For cold water use only.
Temperature Range: 40–100°F (4.4–37.8°C)
• M ake certain that installation complies with all state and local
Pressure Range: 30–125 psi (2.1–8.62 bar)
laws and regulations.
Service Flow Rate @ 60 psi (4.1 bar): 0.6 gpm (2.3 L/min)
• T he contaminants or other substances removed or reduced by
Rated Service Life: 1,000 gallons (3,785L)
Résumé du contenu de la page N° 2
I n s t a l l a t i o n B • F or standard under-sink installation on 1/2"-14 NPS threads (most common 1 thread on kitchen faucets) cold water line. • Please read all instructions and precautions before installing and using your Dual Filtration System. • Numbered diagrams correspond with numbered steps. D 1. Installing the Water Supply Adapter A C The supply adapter fits 1/2"-NPS supply threads. If local codes permit, it may be used to connect the US-1500 to the cold water supply line. If loc
Résumé du contenu de la page N° 3
4. Mounting the System (A) Center system between water supply adapter and drinking water faucet. 4 1 NOTE: Allow 1 ⁄2" (38 mm) clearance below system for changing filter cartridges. 3 1 (B) Install mounting screws at least 13 ⁄4" (350 mm) from cabinet floor and 4 ⁄8" (124 B mm) apart. Leave enough space (approximately 1/2" [13 mm]) between the head of the screw and the wall to slip system onto screws. (C) Place system over screws on wall and slide downwards to lock into place. Make certain
Résumé du contenu de la page N° 4
7. Connecting the System (A) Assemble tubing with system as shown in Fig. 7A, inserting tubing into 7 appropriate inlet or outlet quick-connect fitting until it stops. NOTE: In some installations, connecting the system to the water supply adapter and/or drinking water faucet causes the tubing to enter the quick- connect fitting at a sharp angle. This may exert pressure on the quick- connect fitting and cause it to leak. In these situations, you may wish to use one or both of the quick-connect
Résumé du contenu de la page N° 5
Electronic Monitor Operations Filter Cartridge Replacement The US-1500 system includes an electronic monitor that alerts you • F ilter cartridges the US-1500 will last about 1,000 gallons or twelve when it is time to change your filter cartridges. Both filter cartridges months before they need to be replaced. Filter cartridge life should be changed at the same time to ensure that the monitor works varies depending on usage, and/or water conditions. Changes in properly. The monitor measures actu
Résumé du contenu de la page N° 6
T r o u b l e s h o o t i n g Leaks: ...between cap and bottom of filter housing Turn off water supply valve and turn on drinking water faucet to 3 release pressure in system. Remove bottom of housing. Clean O-ring and O-ring groove (located directly beneath threads of housing). 1 Lubricate O-ring with silicone grease and replace securely into groove. Screw bottom of housing onto cap and hand-tighten. DO NOT OVER-TIGHTEN. Turn on water supply valve and check for leaks. 6 4 ...on system inlet
Résumé du contenu de la page N° 7
Organic Chemicals Included by Surrogate Testing: Performance Data Important Notice: Read this performance data and compare the Maximum permissible capabilities of this system with your actual water treatment needs. Influent Challenge product water Substance Concentration mg/L concentration mg/L It is recommended that, before installing a water treatment system, you have your water supply tested to determine your actual water alachor 0.050 0.001 treatment needs. atrazine 0.100 0.003 benzene
Résumé du contenu de la page N° 8
PENTEK LIMITED WARRANTY PENTEK warrants to the purchase. Any replacement prod warranty does not cover: (1) fi arising from failure to comply party other than PENTEK, (6) problems and/or damage resulting in whole or in part from alteration, modification, repair or attempted alteration, modification or repair by any party other than PENTEK, (7) noncompliance with applicable codes/ordinances. If a defect in workmanship and/or defective product or part (PENTEK may consider, in good faith, the custome