Résumé du contenu de la page N° 1
FP0 Series
Programmable Controllers
07/2007
1
Résumé du contenu de la page N° 2
Control FPWIN Pro FP0 – Super Compact PLC P InL cC re P dr ib olg yr a Sm mm aliln , g A lS oo nf et w oa r rE ev c eo nn a fo s rM mu in ltg ip tlo e I C Eo C m 61 b1 in3 e1 d- 3 Units From I/O 10-points… Actual size COM port: 2nd RS232C interface (optional for all CPU units for serial communication) Compact size A control unit a mere 25mm* in width. Even expanded to 128 I/O points, the width is still only 105mm. The attachment area is one of the smallest in its class.
Résumé du contenu de la page N° 3
Either 10 Points or the Maximum of 128 Points You Save This Much Space! …up to 128 I/Os ! Networking : - ETHERNET - Modbus - PROFIBUS - S-LINK - MEWNET-F ! Analogue modules featuring different numbers of input and output channels ! Programming software: - Control FPWIN Pro according to IEC 61131-3 - Control FPWIN GR easy, conventional programming Easy expansion The expansion unit can be attached easily without any cables. The expansion unit can easily be attached direc
Résumé du contenu de la page N° 4
FP0 CPU Units A Rich Line-Up of Both Single and Combined Units Control units Relay output type Transistor output type 10 points 10 points 14 points 14 points 16 points 16 points 32 points 32 points Input Output Input Output Input Output Input Output Input Output Input Output Input Output Input Output 6 points 4 points 6 points 4 points 8 points 6 points 8 points 6 points 8 points 8 points 8 points 8 points 16 points 16 points 16 points 16 points FP0-C10RSA FP0-C10CRSA FP0-C14RSA FP0-C14CRSA FP0
Résumé du contenu de la page N° 5
FP0 Expansion Units Choose the Number of I/O Points to Suit the Application Digital I/O units Relay output type Input only type Transistor output type 8 points 16 points 32 points 8 points 16 points 8 points 16 points 16 points 32 points Input Output Input Output Input Output Input Input Output Input Output Output Input Output 4 points 4 points 8 points 8 points 16 points 16 points 8 points 16 points 8 points 8 points 8 points 16 points 16 points 16 points FP0-E8RSA FP0-E16RSA FP0-E32RS FP0-E8XA
Résumé du contenu de la page N° 6
FP0 – Impressive Capabilities High Specifications for Both Speed and Capacity 0.9µs per basic instruction. Pulse catch and interrupt input functions meet the need for high-speed response. High-speed execution Execution speed of 0.9µs per basic instruction. 500 step programme yields a scanning time of 1ms. Internal processing in the FP0 Pulse catch function Interrupt input function Can read pulses as short as 50µs, which facilitates sensor Accurate processing, unaffected by scan tim
Résumé du contenu de la page N° 7
FP0 – Impressive Capabilities FP0 Functions Equipped with 2-axis independent positioning and high-speed counter for support of PWM output. Pulse output function The unit comes equipped with 2 channels for the output of up to 10kHz Pulse output Y0 Clockwise output/ Motor Stepping motor pulses (5kHz during 2-channel output). Since these two channels can counter-clockwise output driver 1 Servo motor Y2 be separately controlled, the PLC is also suitable for independent 2- Pulse output axis positio
Résumé du contenu de la page N° 8
FP0 Communication Serial Interfaces and Modem Compatible Communication – Simple and efficient via two serial interfaces: TOOL port and COM port (RS232C interface). Programming interface TOOL port (also for communication) In MEWTOCOL-COM Slave mode, this port offers access to the entire FP0 memory area. For example during data exchange ® between a host PC running SCADA software and an FP0 PLC, the Windows based FP OPC Server assumes total control of the communications protocol (MEWTOCOL.COM). T
Résumé du contenu de la page N° 9
FP0 Communication Easier Maintenance Than Ever Before Maintenance saving Program memory uses EEPROM. In addition, programmes can be changed even in RUN mode! ! Overwrite function in RUN mode It is possible to overwrite a program while the FP0 is running, such as during program debugging and startup adjustments. ! Backup battery unnecessary The program memory uses EEPROM. The program and device contents can be stored without a backup battery, and even programming for a machine builder is saf
Résumé du contenu de la page N° 10
FP0 PROFIBUS DP Slave or Remote I/O Unit For Cost Effective Control of Distributed Field Device The FP0 DPS2 can operate either as a DP Slave module or as a remote I/O system to which different decentralised inputs and outputs can be connected. A DIP switch can be used to switch between the two modes: Mode 1: DP Slave module. Connect the FP0 or FPΣ (Sigma) CPU + expansion modules to the PROFIBUS network. Mode 2: Remote I/O. Connect up to three expansion modules without CPU to the PROFIBUS n
Résumé du contenu de la page N° 11
FP0 S-LINK Unit Connects Directly to the S-LINK for Reduced Wiring S-Link is a system which simplifies connection of rapidly increasing control devices accompanying progressing automation and is useful in reducing your costs and construction time. Features 1. Small size of only W30xH90xD60mm. Makes use of the T-shaped connectability of the S-LINK for reduced wiring and reduced size of the control panel. 2. Controls 64 input points and 64 output points. Able to control up to 128 points for S
Résumé du contenu de la page N° 12
FP0 MEWNET-F Unit Networking Units MEWNET-F The FP0 can be used as a slave station for MEWNET-F (remote I/O system) by adding I/O link unit. MEWNET-F is a reduced-wiring, remote I/O system that connects PLCs located separately and I/O slave stations with 2-core cabling. By adding an I/O link unit to the FP0, you can link master station PLC and FP0 inputs and outputs via the network. FP2 (Master station) Twisted pair cable or VCTF FP0 (Slave station) FP0 (Slave station) FP0 (Slave station) FP0
Résumé du contenu de la page N° 13
Analogue Signal Processing FP0 Analogue Units Features FP0-A21 FP0-A80 FP0-A04V FP0-A04I 2 Inputs/1 Output 8 Inputs 4 Outputs 4 Outputs ! Multimode A/D, D/A conversion ! High resolution: 12-bit Voltage, current and temperature selectable ! 2 analogue inputs (FP0-A21): ! High conversion speed -10 to + 10V, 0 to 5V, 0 to 20mA, FP0-A04V, FP0-A04I: 500µs 8 analogue inputs (FP0-A80): -10 to + 10V, 0 to 5V, -100 to + 100mV, 0 to 20mA ! PID instruction with auto tuning ! 1 analo
Résumé du contenu de la page N° 14
Analogue Signal Processing FP0 Analogue Units General specifications Item Description Rated operating voltage 24VDC Operating voltage range 21.6 to 26.4VDC Rated current consumption FP0-A80: 60mA or less, FP0-A21/A04V: 100mA or less, FP0-A04I: 130mA or less Ambient temperature 0°C to + 55°C Storage temperature -20°C to + 70°C Size 90 x 25 x 60mm Weight Approximately 100g Analogue input specification Item Description Product FP0-A21 FP0-A80 Number of channels 2 channels/unit 8 c
Résumé du contenu de la page N° 15
FP0 Thermocouple Input Expansion Units Enable High Precision Temperature Control at Low Cost The FP0-TC4 and FP0-TC8 thermocouple units are suitable for user-friendly Temperature control temperature acquisition using standard thermocouples with high precision. ! Up to three units can be added to each control unit, enabling temperature control of up to 24 channels. ! The temperature data obtained using the thermocouple is converted to the digital value to be read into the FP0 control unit. !
Résumé du contenu de la page N° 16
FP0 RTD Input Expansion Unit User Friendly Acquisition of Temperatures with High Precision Features ! The module can be easily installed in an existing system. Special connection cables, backplanes, and so forth are unnecessary as the expansion unit employs a stacking system that uses expansion connectors and lock levers on the surface of the unit itself. ! Multiple RTD types are allowed in one module, creating a cost-effective solution. ! About the application areas: - Measurement and
Résumé du contenu de la page N° 17
FP0 Series Specification Tables FP0 specifications
Résumé du contenu de la page N° 18
FP0 Series Specification Tables Interfaces Item Description RS232, mini DIN socket (5 pin), 9600 or 19200 BAUD, (8 data bits, odd parity, 1 stop bit), Computer link for pro- Programming TOOL port gramming and communication with MEWTOCOL-COM, user configurable modem connection RS232 (SD, RD, GND) 3 way screw terminal, 300 to 19200 BAUD, (7 or 8 data bits, none/even/odd parity, 1 or 2 stop bits, start code: none/STX, end code: CR/CR+LF/ETX/none, CCU mode for programming and com- Communication COM
Résumé du contenu de la page N° 19
Control FPWIN Pro Programming According to the International Standard IEC 61131-3 FPWIN Pro is the Panasonic programming software developed according to the international standard IEC 61131-3 (for Windows 98, NT V4.0, 2000, ME or XP). This new version is a result of experience gained over many years. We were one of the first PLC manufacturers to offer an IEC 61131-3 programming software, and we are a leading member of the international organisation PLCopen. Multiple address assigment Local va
Résumé du contenu de la page N° 20
FP Web-Server Programme/Operate the FP0 Using a LAN or WAN Network The multifunctional FP Web-Server provides users with the option of connecting the FP0 or any other FP Series PLC to the Internet/Intranet thus enabling bi-directional communication. No changes to the PLC programs are necessary. Simply assign an IP address to the FP Web-Server and connect the PLC to the FP Web-Server via the serial RS232C interface. A standard browser e.g. MS Internet Explorer or Netscape Navigator can be us