Résumé du contenu de la page N° 1
531
OWNERS MANUAL
MODEL
WVSW
VENTLESS
HOOD
For
CONVEYOR
WARMERS
Includes
INSTALLATION
USE & CARE
SERVICE
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APP
Résumé du contenu de la page N° 2
LIMITED WARRANTY STATEMENT Unless otherwise specified, all commercial cooking equip- thorized personnel. The prices charged by Wells Mfg. Co. ment manufactured by WELLS MFG. CO. is warranted for its products are based upon the limitations in this war- against defects in materials and workmanship for a period of ranty. Seller’s obligation under this warranty is limited to the one year from the date of original installation or 18 months repair of defects without charge by a Wells Mfg. Co. fact
Résumé du contenu de la page N° 3
TABLE OF CONTENTS WARRANTY xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 AGENCY LISTING INFORMATION 3 PRECAUTIONS & GENERAL INFORMATION 4 INSTALLATION 5 OPERATION
Résumé du contenu de la page N° 4
FEATURES & OPERATING CONTROLS WVSW VENTLESS HOOD Fig. 1 Features & Operating Controls 2
Résumé du contenu de la page N° 5
FEATURES & OPERATING CONTROLS (continued) ITEM DESCRIPTION CANOPY Removable canopies aid in vapor capture at entry and exit of the conveyor warmer. Canopies hang from mounting pins at each end of the hood. ELECTRICAL The hood plugs into a NEMA 5-15R (120V) or 6-15R (208/240V) receptacle with a 6' power cord. An illuminated power switch on the front panel is used to start/stop the hood fan. EXHAUST The hood uses an exhaust fan to provide air movement. The fan exhausts through a screen
Résumé du contenu de la page N° 6
PRECAUTIONS AND GENERAL INFORMATION This appliance is intended for use in commercial establishments WARNING: only. Electric Shock hazard This appliance is intended as a smoke and odor control device, designed for use with specified warming equipment. No other use is All servicing requiring recommended or authorized by the manufacturer or its agents. access to non-insulated Operators of this appliance must be familiar with the appliance use, electrical components limitation
Résumé du contenu de la page N° 7
INSTALLATION UNPACKING & INSPECTION NOTE: DO NOT discard the carton or other packing Carefully read all instructions in this manual before starting any materials until you have installation. inspected the hood for hidden Carefully remove the hood from the carton. damage and tested it for proper operation. IMPORTANT: Appliance weighs 92 lbs (42.7 kg). Use appropriate Refer to SHIPPING DAMAGE care when removing from carton and installing on conveyor warmer. CLAIM PROCEDURE o
Résumé du contenu de la page N° 8
INSTALLATION (continued) ELECTRICAL INSTALLATION WARNING! Electric Refer to the nameplate. Verify the electrical power source. Voltage Shock hazard and phase must match the nameplate specifications. Plugging the All servicing requiring hood into the wrong voltage can severely damage the unit . access to non-insulated Your hood is equipped with a grounded electrical cord. This cord electrical components must be plugged into a properly grounded NEMA 5-15R (120V) or must be p
Résumé du contenu de la page N° 9
OPERATION OPERATING CONTROLS Controls include a lighted POWER SWITCH and an amber REPLACE FILTER indicator light. Press POWER SWITCH to ON anytime conveyor warmer is operating. When power is first turned on, the REPLACE FILTER light will glow. As the fan comes up to speed and air flow is established, the REPLACE FILTER light will go out. If the REPLACE FILTER light does not go out, the filters must be replaced. However, the fan will continue to operate when the
Résumé du contenu de la page N° 10
CLEANING INSTRUCTIONS CAUTION! PREPARATION Unplug hood and conveyor warmer Allow to cool completely before cleaning Personal Injury Hazard FREQUENCY Daily Disconnect power from hood TOOLS Mild Detergent and conveyor warmer before Soft Cloth or Sponge cleaning. 1. Disconnect power from hood and conveyor warmer before cleaning. IMPORTANT: DO NOT spill or po
Résumé du contenu de la page N° 11
TROUBLESHOOTING SUGGESTIONS SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Plug cord into appropriate power No operation, no lights Cord unplugged receptacle. Circuit breaker off or tripped Reset circuit breaker Damaged power cord or plug Replace power cord Damaged power switch Replace power switch REPLACE FILTER light remains Filters dirty Replace filters lit (never shuts off) If filters are clean New filter still in plastic wrapper Remove plastic wrapper and fan is operating Clear
Résumé du contenu de la page N° 12
SERVICE INSRTUCTIONS IMPORTANT: VACUUM DIAGRAM DO NOT store anything on top of the hood. DO NOT block the exhaust opening. Filter operation is monitored by a vacuum switch and a system of vacuum hoses. The switch energizes the REPLACE FILTER light if airflow through the filters is insufficient for efficient operation. The light is a warning only, and does not control the operation of the hood. 10
Résumé du contenu de la page N° 13
PARTS & SERVICE DESCRIPTION PART NO. IMPORTANT: Use only factory authorized service HIGH EFFICIENCY FILTER 16 x 20x 4 22862 parts and replacement filters. CHARCOAL (CARBON) FILTER 14 x 20 x 7/8 22403 For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call: Wells Manufacturing Co. 2 Erik Circle P. O. Box 280 Verdi,
Résumé du contenu de la page N° 14