Résumé du contenu de la page N° 1
POS / CASH REGISTER
INTERFACE
Operation Manual
September 2008
1
Résumé du contenu de la page N° 2
VSI-Pro Max CAUTION! RISK OF ELECTRICAL SHOCK! DO NOT OPEN! TO PREVENT ELECTRIC SHOCK, DO NOT REMOVE THE COVER. DO NOT EXPOSE THE EQUIPMENT TO RAIN OR MOISTURE. NO USER SERVICEABLE PARTS ARE INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. WARNING! THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FRE- QUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCOR- DANCE WITH THE INSTRUCTION MANUAL MAY CAUSE INTERFER- ENCE TO RADIO COMMUNICATIONS. IT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS
Résumé du contenu de la page N° 3
CONTENTS 1. Introduction.........................................................................................................................................................7 1.1 VSI / VSI+ / VSI-Pro / VSI-Pro Max Backward Compatibility ......................................................................7 2. Features & Specifications....................................................................................................................................8 2.1 Features..........
Résumé du contenu de la page N° 4
CONTENTS Alarm Duration.............................................................................................................................45 Flag Type......................................................................................................................................45 Flag Duration................................................................................................................................45 Triggered Text.............................................
Résumé du contenu de la page N° 5
CONTENTS Figure 11 : Register Select Sub-Menu.................................................................................................................17 figure 12 : TCPIP Sub Menu..............................................................................................................................17 Figure 13 : Addressable VSI Sub-Menu (VSI-ADD) ....................................................................................................18 Figure 14 : ADS Sub-Menu..........
Résumé du contenu de la page N° 6
CONTENTS Figure 78 : Recerve [ RX ] Test Sub-Menu...............................................................................................................47 Figure 79 : Transmit [ RX ] Test Sub-Menu..............................................................................................................48 Figure 80 : RX / TX Test Sub-Menu..........................................................................................................................48 Figure 81 : Baudrate Scan
Résumé du contenu de la page N° 7
1. INTRODUCTION The VSI-Pro Max is the latest in the evolution of the popular VSI line of POS / Cash Register Interfaces from AVE. The VSI-Pro Max, now with larger memory space can hold ALL the AVE Interfaces in one unit with full remote PC or DVR programming for selection and setups and onsite firmware updating. New video processing circuitry allows use with new WDR cameras and low video of commonly used UTP adapters. Built in RS-232, RS-485, Passive and the new Opto-Isolated selection, gives c
Résumé du contenu de la page N° 8
2. FEATURES & SPECIFICATIONS 2.1 FEATURES ............80 Register Selections Selectable via OSD ............User Selectable Full Duplex Bi-Directional POS / Cash Register Communications RS-232C RS-232C Optically Isolated RS-485 Full Duplex, RS-422 Half Duplex Passive Tap (Hi-Z) ............RS-232C or RS-485 Output of all data or exceptions to printers, computers, modems and DVRs ............Dual RJ45 Connectors for easy Networking with Standard CAT5 Cabling ............Built In Hydra, Regcom, Ne
Résumé du contenu de la page N° 9
FEATURES & SPECIFICATIONS 2.2 SPECIFICATIONS Video In (BNC) .5VP-P to 2VP-P AGC Term. 75 ohms, 90V Gas Discharge Suppression Video Out (BNC) 1V P-P Terminated or Unterminated can drive two 75 ohm loads Video S / N better than 50dB Video B / W better than 7MHz Power (DC Coax 2.1mmx5.5mm) 9-12VDC 170mA 18V MOV Surge Suppression Battery Backup NiMH 1 year with 24 hour charge Register Serial Port Bi-Directional RS-232C RS-232 Opto RS-485 / RS-422 PassiveHi-Z (DB9 Female) RXD - Pin 2 RXD - Pin 2
Résumé du contenu de la page N° 10
3. CONNECTIONS The VSI-Pro Max will overlay the characters on any input video source. The video input can be virtually any baseband or composite video source. The VSI-Pro will accept NTSC, RS-170, RS-330, CCIR, PAL or SECAM video formats.The Video input to the VSI-Pro Max is a standard BNC connector, terminated at 75 [ohms]. NOTE The input video level must be between 0.5V - 2.0V Peak to Peak. If the video is lower or not present the VL LED will illuminate signifying low or no video and the VS
Résumé du contenu de la page N° 11
CONNECTIONS Pin # Label Direction Function 1 Alarm Out 1 From VSI-Pro Max Open Collector Transisitor 2 Receive Data To VSI-Pro Max Data from Cash Register 3 Transmit Data From VSI-Pro Max Data to Cash Register 4 DTR From VSI-Pro Max Remain High or RS-485 Input (+)(A) 5 Ground ------------------- Signal / Power Gnd or Isolated RS-232 Input Gnd 6 DSR From VSI-Pro Max Remain High or RS-485 Input (-)(B) 7 RTS To VSI-Pro Max Alarm Input or Hardware Handshaking 8 CTS From VSI-Pro Max DVR RS-232 Output
Résumé du contenu de la page N° 12
CONNECTIONS PIN # FUNCTION DIRECTION 1 Alarm Out 1 Open Collector Transisitor 2 No Function No Function 3 TXD RS-232 From VSI-Pro Max (Option) 4 RS-485 (+) A Data From or To VSI-Pro Max 5 Ground 6 RS-485 (-) B Data From or To VSI-Pro Max 7 RTS ( Alarm In ) To VSI-Pro Max 8 CTS From VSI-Pro Max 9 Alarm Out 2 Open Collector Transistor Note: When the RS-485 port is set for Bi-Directional RS-485 the TXD port has no function. When the RS- 485 port is set for recieve data only then the TXD port can b
Résumé du contenu de la page N° 13
CONNECTIONS Grounding and Isolation The VSI-Pro Max has an isolated internal signal/power ground from the case or chassis ground. Therefore maintain- ing this isolation will insure proper surge and lightning suppression when the chassis grounded properly. Video Surge / Lightning Protection The VSI-Pro Max has an internal Gas Discharge Surge Suppressor on the video input. This enables high input surges to be suppressed so not to damage the internal circuitry of the VSI-Pro Max. Voltage spikes bet
Résumé du contenu de la page N° 14
4. USER FRONT PANEL CONTROLS The VSI-Pro Max is programmed by pressing and releasing specific combinations of the four front panel push- buttons. Via these four simple buttons, all of the powerful programming features of the Text Inserter are available. A video source and a monitor must be connected in order to see the programming menus. Down Up Set Reset Figure 6 : Four Front Pannel Push Buttons of VSI-Pro Max 4.1 FRONT PANEL CONTROLS The front panel controls are provided to allow simple changi
Résumé du contenu de la page N° 15
USER FRONT PANEL CONTROLS Changing the Horizontal Position Down Up Set Reset Figure 8: Four Front Pannel Push Buttons of VSI-Pro Max (Up) 1. Press and hold the “Up” button. 2. Press and release the “Reset” button. 3. Release the “Up” button. 4. Press “Down” or “Up” to move the text block. 5. When the choice is made, press and release the “Set” button. Changing the Vertical Position Down Up Set Reset Figure 9: Four Front Pannel Push Buttons of VSI-Pro Max (Set) 1) Press and hold the “Set” button.
Résumé du contenu de la page N° 16
5. PROGRAMMING 5.1 GETTING STARTED To access the main-menu of the VSI-Pro Max, simultaneously hold down the “Down” & “Up” buttons and press and release the “Reset” button and then release the “Down” & “Up” buttons. This will take you to the main programming menu. To navigate through this menu, simply use the “Down” and “Up” buttons to position the cursor in front of the desired function, then press “Set” to access that function. If you have difficulty entering the main-menu, try the following pr
Résumé du contenu de la page N° 17
PROGRAMMING TCP/IP 3. Press the “Up” or “Down” button to move the Press the “Up” or “Down” button to move the cursor to cursor to “EXIT” and press “Set” to return to the “REGISTER SELECT” and press “Set”. The REGIS- previous menu. TER SELECT menu will appear: Refer to Appendix I for additional information on the TCPIP232 Adapter or the manual included with the GENERIC adapter. TCPIP ADDRESSABLE VSI NOTE: The TCPIP232 Adapter can be programmed AD4323 by this method or by using a standard PC with
Résumé du contenu de la page N° 18
PROGRAMMING GENERIC BEETLE/50 PRINTERS Press the “Up” or “Down” button to move the cursor to Press the “Up” or “Down” button to move the cursor to “PC COM 1,2,3,4” and press “Set”. No menu will apprear “NIXDORF BEETLE” and press “Set”. The NIXDORF and merely sets the VSI-Pro Max to “Generic” mode. BEETLE menu will appear: ADDRESSABLE VSI (VSI-ADD) REMOTE SLIP OPERATOR DISPLAY Press the “Up” or “Down” button to move the cursor to “ADDRESSABLE VSI” and press “Set”. The ADDRESS- Figure 15: NIXDORF
Résumé du contenu de la page N° 19
PROGRAMMING DELTA SONO 3.1 EDACOM Press the “Up” or “Down” button to move the cursor to Press the “Up” or “Down” button to move the cursor to “DELTA SONO 3.1” and press “Set”. The DELTA SONO “EDACOM” and press “Set”. The EDACOM menu will 3.1 menu will appear: appear: MODEL E90 DELTA JOURNAL EXIT DELTA RECEIPT EPSON JOURNAL Figure 23: EDACOM Sub-Menu EPSON RECEIPT EXIT Press the “Up” or “Down” button to move the cursor to “MODEL E90” and press “Set”. The MODEL E90 menu will appear: Figure
Résumé du contenu de la page N° 20
PROGRAMMING GASBOY IBM RDS Press the “Up” or “Down” button to move the cursor to Press the “Up” or “Down” button to move the cursor to “GASBOY” and press “Set”. The GASBOY20-A menu “IBM RDS ” and press “Set”. The IBM RDS menu will will appear: appear: DEVICE CONSOLE DISPLAY JOURNAL DEVICE ADDRESS 01 EXIT EXIT Figure 30: IBM RDS Sub-Menu Figure 27: GASBOY Sub-Menu DISPLAY DEVICE Choices: JOURNAL, RECEIPT, MIXED Choices: PRINTER, CONSOLE,CSL OLD MICRELEC DEVICE ADDRESS Press t