Résumé du contenu de la page N° 1
WINDOW TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HW-07LM13
HW-07LM03
HW-09LM13
HW-09LM03
HW-12LM13
HW-12LM03
Please read this operation manual
before using the air conditioner.
Please keep it attentively.
No.0010515220
Résumé du contenu de la page N° 2
Contents Contents ............................................................................... 2 Part Name.............................................................................. 3 Operation Guide ................................................................ 4-5 Maintenance ...................................................................... 6-8 Trouble shooting ................................................................... 9 Installation Instructions....................
Résumé du contenu de la page N° 3
Parts Name Machine body Front panel Air inlet (indoor side) Machine body Air outlet (indoor side) Air inlet (outdoor side) Display panel Power plug Air filter (inside) Operation panel LOW HIGH FAN FAN MINI MAX LOW HIGH COOL COOL COOL COOL WAIT THREE MINUTES BEFORE RESTARTING 3
Résumé du contenu de la page N° 4
Operation Guide Auto swing switch When the switch is set to " ", and vertical louvers will swing from side to side, delivering gentle air thus making you feel very comfortable. When it is set to " ", the indicator goes out, and the vertical louvers stop at any position. Mode selection switch Mode selection switch controls the fan motor speed and cooling speed. <1> When set to " HIGH FAN", fan motor runs at high speed to blow out strong air. <2> When set to "LOW FAN", fan motor runs at lo
Résumé du contenu de la page N° 5
Operation Guide Thermostat switch This switch controls the preset indoor temperature to makethe air conditioner start or stop automatically, so as to reduce power consumption and operate the system both comfortably and economically. Remark: The compressor stops running when the set temperature is reached but the fan continues to operate to keep an even indoor temperature. Airflow Direction Vane Vertical airflow direction The Vertical Airflow Direction Vane is manually controlled by positioning t
Résumé du contenu de la page N° 6
Maintenance Air filter cleaning (before cleaning, turn off the power) When dirt accumulates on air filter, air circulation will be blocked, which causes poor cooling. It is advisable to clean air filter every two weeks for longer operation. Take out the air filter 1.Press the concave parts on both sides at the lower part of air inlet grille to open the air inlet grille. 2.Hold the hump of filter mesh with fingers (as illustrated) and take it out. Hump Air filter cleaning Cleaning of th
Résumé du contenu de la page N° 7
Maintenance Disposal of the condensed water Generally there are two methods available on disposal of the condensed water: 1. Block the bottom plate hole of the conditioner with rubber lid, install outlet pipe fitting on the back hole and let the condensing water flow from the back hole of the conditioner. (See Fig.1 ) In this method, the accumulated condensed water in the bottom plate is hit by the fan onto the heat exchanger, and evaporated and blown out from the machine. It can cool the he
Résumé du contenu de la page N° 8
Maintenance Avoid opening doors and windows Don't be exposed to cold air for unless necessary. a long time. Use curtain or blind Keep heat source away from Direct sunlight may reduce cooling air conditioner. effect, always use window curtain. After unit stops, don't restart it Set temp . a little bit higher until 3 min. have elapsed. before going to bed. OK! Enjoy a Proper temperature 3-min nap 8
Résumé du contenu de la page N° 9
Troubleshooting Readjust power supply. Replace fuse. Doesn't work Is plug firmly inserted? Is there power failure? Readjust the thermostat. Does fuse get burned? Use curtain or blind. Is thermostat switch wrongly adjusted? No cool air or Shut doors and windows. poor cooling Is there any direct sunlight in the room? Remove the obstacles. Are doors or windows left open? Clean it. Are there any obstacles blocking air inlet and outlet? Is air filter clogged? Remove the heat source Is there too much
Résumé du contenu de la page N° 10
Installation Instructions Don't hang clothes in the vicinity Temperature should be set of air inlet. This will decrease properly when there are infant, cooling effect and cause abnormal child, the aged or disabled operation. in the room. Baby has gone sleep, better to adjust suitable temp. Before operating mode selection switch, check that if the air inlet or outlet have been blocked. For longer and trouble-free operation of the unit, pay special attention to the following: Install air-con at a
Résumé du contenu de la page N° 11
Installation Guide Selection of the installation position 1. The air-conditioner is better installed in shadow or in a place with short period of sunshine. In case the air-conditioner is installed at the point exposed directly to the sunshine, it should be protected from the direct sunlight as possible in order to avoid the long time of direct sunlight otherwise its performance will be lowered. (As illustrated in Fig. 1). 2. For the convenience of operation, it is recommended that air-conditione
Résumé du contenu de la page N° 12
450 Installation Guide Installation of air-conditioner (only for reference) Iron frame 350 1. Make the wall hole or window hole (see Fig.1). 2. Fix the prefabricated iron frame to stable position by expansible screws. 3.Take out the conditioner and accessories Width of the wall from the package . Fig. 1 Cooling-only type air-conditioner: before dispatched Condenser 4. from the factory, the drip hole at the bottom plate has been blocked by rubber lid in the accessories. If the surroundin