Résumé du contenu de la page N° 1
EUROCHEF - PRO WALL HOOD
EUROCHEF - PRO WALL HOOD
INSTALLATION INSTRUCTIONS
2 3 TIMER
1
Shown with accessory Duct Cover Kit and accessory Warming Lamp Kit
APPROVED FOR ALL RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Leave these Instructions with this unit for the owner.
OWNER: Retain these instructions for f
Résumé du contenu de la page N° 2
EUROCHEF - PRO WALL HOOD HOODS WEIGHT MODEL NUMBER FEATURES Controls: 4-speed electronic with 15” minute delayed shutoff 24” range hood with 600 CFM blower 22 lbs EC PH24S timer 30” range hood with 600 CFM blower 30 lbs EC PH30S Fabrication: Welded, polished and brushed seams 36” range hood with 600 CFM blower 36 lbs EC PH36S All edges hemmed Features: 304 stainless hood baffle filter and grease tray 48” range hood with 1200 CFM blower 48 lbs EC PH48S 12V halogen lighting, lamps included Top and
Résumé du contenu de la page N° 3
EUROCHEF - PRO WALL HOOD READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY CONSIDERATIONS BEFORE WARNING INSTALLING HOOD TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. For the most efficient air flow exhaust, use a straight run or as few A. Use this unit only in the manner intended by the manufac- elbows as possible. turer. If you have any questions, contact the manufacturer. 2. Do not use flex ducting use metal ductwork only to reduce the risk B. Be
Résumé du contenu de la page N° 4
EUROCHEF - PRO WALL HOOD PRODUCT DIMENSIONS CONTENTS AND PAGE NUMBER Product Dimensions....................................................... pg.4 Advance Planning...........................................................pg.5 Using Duct Cover Accessories........................................ pg.5 Tools and Materials Required ......................................... pg.5 Remove the packaging................................................... pg.6 Parts Provided...............................
Résumé du contenu de la page N° 5
EUROCHEF - PRO WALL HOOD ADVANCE PLANNING 36” (914 mm) Cabinetry and electrical placement for 24-inch deep wall hoods. lnstallatian dimensions for 24 deep wall hoods. USING DUCT COVER ACCESSORIES To avoid gaps, plan the hood installation height for duct cover use. Recirculating Kit Cover 4” (if used) Duct cover 6” Duct cover 12” 1. Duct covers and Recirculating Kit covers are stackable. 2. The hood is 18” tall and can be installed from 24” to 36” above cooking surface (30” to 36” is optimum). 3
Résumé du contenu de la page N° 6
EUROCHEF - PRO WALL HOOD Parts Included with your Hood REMOVE THE RANGEHOOD • Hood with blower installed DO NOT GRAB BODY HERE • 12-Volt halogen bulbs, installed • Care & Use /Installation Instructions • Registration Card GRAB BODY HERE • Filters (24” & 30” = 2; 36” = 3; 48” = 4) • Grease trap (24” & 30” = 2; 36” = 3; 48” = 4) • Transition with Back draft damper GRAB BODY • Fasteners HERE • Wooden bracket for Hood Support Parts Not Included with your Hood • Duct Cover Kit, 6" or 12" height
Résumé du contenu de la page N° 7
EUROCHEF - PRO WALL HOOD REMOVE FILTER FRAME STEP 1 DETERMINE HOOD, DUCTWORK - Remove Filter Frame per photographs AND WIRING LOCATIONS - Store Filter Frame in safe place so it will not be damaged. - Do not loose the Filter Frame screws, re-screw them loosely, • Use a level to draw the cooktop centerline vertically up the back into the hood. wall to the ceiling. • Measure desired distance from the bottom of the hood to OTHER PREPARATIONS the cooking surface, 24" min. to 36" max. • Move blower to
Résumé du contenu de la page N° 8
EUROCHEF - PRO WALL HOOD BLOWER POSITION CHART Hood size Motor Recirculating Kit option Top ducting option Rear ducting option 24” 1 YES YES YES 30” 1 YES YES YES 30” 2* NO YES NO 36” 1 YES YES YES 36” 2* NO YES NO 48” 2 NO YES NO (*) with Blower Upgrade Kit BLOWER POSITION OPTION model 24 model 30 36 model 30 36 Vertical Discharge Vertical Discharge model 48 two blowers Vertical Discharge (with Blower Upgrade Kit) model 24 model 30 36 model 30 36 Horizontal Discharge Horizontal Discharge m
Résumé du contenu de la page N° 9
EUROCHEF - PRO WALL HOOD IF CHANGING BLOWER POSITION SECURITY SCREW 1. Disconnect motor from power supply 2. Remove Blower security screw from blower bracket and remove blower. 3. Loosen 4 screws from blower bracket. 4. Shift blower to right and Remove Blower. 5. Loosen 4 screws and remove sealing plate covering back venting hole. 6. Reverse this procedure in new locations. 7. Reconnect blower to power supply. BLOWER UPGRADE KIT 30” AND 36” HOODS A “A”: remove bracket knock out nd before fixing
Résumé du contenu de la page N° 10
1 2 3 TIMER TIMER EUROCHEF - PRO WALL HOOD STEP 3A: INSTALL HOOD ONTO WALL (see enclosed template) SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR CABINET, GO TO STEP 3B. • Affix enclosed paper template to wall. • Insert hood mounting screws in the Wood Bracket at the • From the line indicating the bottom of the hood, measure locations shown in the diagram, so screws protrudes 1/4". 17” up and draw another line for the location of the Wood This 1/4” gap will provide clearance to hang the hood
Résumé du contenu de la page N° 11
EUROCHEF - PRO WALL HOOD • Affix enclosed paper template to wall STEP 3B: ALTERNATE MOUNTING METHOD IMPORTANT: FRAMING MUST BE CAPABLE OF INSTALL HOOD TO SOFFIT OR BENEATH CABINETS SUPPORTING UP TO 150 LBS SKIP THIS STEP IF USING WALL MOUNTING METHOD Mount Hood onto Soffit or Cabinet When necessary, the hood may be installed so that it is supported by the soffit. Note: If mounting to the underside of a cabinet with a recessed • The soffit should be constructed with 2 x 4’s. bottom, install shims
Résumé du contenu de la page N° 12
EUROCHEF - PRO WALL HOOD • Use wire nuts to connect incoming ground, neutral and hot. STEP 4: CONNECT DUCTWORK • Push wires into junction box and replace cover. Be sure wires are not pinched. • Install ductwork. • Secure joints in ductwork and transition with sheetmetal screws and duct tape for an airtight seal. STEP 6: INSTALL DUCT COVERS • ATTENTION: Be sure that screws do not hamper the dampers movement. STEP 5: CONNECT ELECTRICAL Verify that power is turned off at the source. WARN
Résumé du contenu de la page N° 13
EUROCHEF - PRO WALL HOOD STEP 7: TIGHTEN - HANGING SCREWS • With Filter Frame still removed from Step 2 • Adjust hood up to eliminate any gaps at ceiling. Tighten hanging screws. • Add (2) more security screws + Washers at wood bracket. • IMPORTANT: If Installing optional Backsplash Kit install this kit BEFORE installing wall anchors (see instruction with kit) Install Bottom Wall Anchors • Drill 1//8" pilot holes into the two lower mounting holes. Enlarge the holes if they did not enter stud
Résumé du contenu de la page N° 14
EUROCHEF - PRO WALL HOOD STEP 9: INSTALL FILTER STEP 10: TEST FUNCTION OF HOOD - Blower - Light • Place filter drip trays into the bottom rear of the hood. • Insert top of grease filter first, than rotate bottom filter and drop into grease tray. • To remove the filters, grasp the handle, push the filter up and lift out. Air-2 14
Résumé du contenu de la page N° 15
EUROCHEF - PRO WALL HOOD CARE AND USE OPERATION Press any speed to turn hood on. Press same button to turn REPLACING HALOGEN BULB hood off. Active speed is shown by a button back light. ROTATE CONTROL: 1. 1 Speed 2. 2 Speed 3. 3 Speed 4. 4 Speed Light DELAYED SHUTOFF By pressing down on any speed key for 2 seconds, while hood is running the 15 minute Delayed Shutoff mode will start indicated by flashing backlight. After 15 minutes the hood will shutoff. WARRANTY: Eurochef USA warrants the USA
Résumé du contenu de la page N° 16
EUROCHEF - PRO WALL HOOD EUROCHEF U.S.A. 41 MERCEDES WAY SUITE 25 EDGEWOOD NEW YORK 11717 – TEL. 866-844-6566 WWW.DELONGHIMAJORAPPLIANCES.COM WWW .DELONGHI RANGES.COM Air-2 16