Résumé du contenu de la page N° 1
EVM9 Extractors
Manual for Installation, Use and Maintenance
Passionate about style
Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY
T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.eu
Résumé du contenu de la page N° 2
Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that the manufacturer reserves the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment. This appliance is not designed to be used by people (including children) with reduced physical, sensorial or mental capacity, or who lack experience or knowle
Résumé du contenu de la page N° 3
Using your Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. Control Panel A - Light key B - Decrease speed key C - Display D - Increase speed key E - Timer key Fig. 1 B A C D E To switch the extractor light on and off • Touch key A. To switch on the extractor • Touch either key B or D. The appliance will switch on at the first speed. • To increase the speed
Résumé du contenu de la page N° 4
Care and Maintenance IMPORTANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. 2 Cleaning You should use a nonabrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. You can clean your extractor effectively by simply using a dilute solution of water 2 and mild detergent and drying to a shine with a clean cloth. 1 Cleaning the grease filter The grease filter sh
Résumé du contenu de la page N° 5
Changing the Light IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO COOL BEFORE REMOVING IT. Carefully prise the bulb from the extractor using a small, flat-bladed screwdriver. Refit the new bulb taking care not to touch the glass (Fingerprints will lead to premature failure of the bulb). Fig. 5 Do not touch bulbs or adjacent areas
Résumé du contenu de la page N° 6
Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations. DOUBLE POLE SWITCHED The wires in the mains lead of this appliance are coloured in accordance with the FUSED SPUR OUTLET following
Résumé du contenu de la page N° 7
Installation Your extractor can be used to filter and recycle the air within your kitchen, or to extract the air outside. When extracting air to the outside, the unit can be vented as shown in the diagram below. Note that we recommend the use of ducting with a diameter of 150mm. Ducting with diameters of 100mm or 120mm may be used, but performance will be reduced. When installing this appliance over a CDA hob, the clearance between the extractor and the hob must be equal to or exceed 450m
Résumé du contenu de la page N° 8
Fitting your extractor to the wall Next, remove the top cover by loosening the screws (b), closing the front panel and then lifting the cover off. The extractor is mounted using four screws. Ensure that the wall fixings and screws are suitable for the wall material. Mark the positions of the four holes on the wall, according to (fig 11.) Fig. 9 Fig. 10 460 178 112.5 + 450mm for CDA Hob Fig. 11 7
Résumé du contenu de la page N° 9
Fitting your extractor to the wall Insert the 4 wall plugs in to the holes and fix 2 screws in the top holes so that they are protruding from the wall by approx 5mm (fig 12). Next, lift the hood onto the 2 screws as shown in (fig12). Secure the top two screws and fix the hood into position using screws inserted into the 2 lower holes (fig 13). The extractor is now secured to the wall. Fig. 12 Fig. 13 Using the extractor as a recirculation device Refit the top cover and grill as below before
Résumé du contenu de la page N° 10
Using the extractor as an extraction device Work out the required height of the optional chimney for your ceiling and mount the chimney fixing bracket as shown in the (fig 16), then secure the chimney as shown in (fig 17a). Finally, locate the chimney to the body of the extractor as shown in (fig 18). Fig. 16 Fig. 17 Fig. 18 9 20
Résumé du contenu de la page N° 11
10
Résumé du contenu de la page N° 12
To contact our Customer Care Department, or for Service, please contact us on the details below. Passionate about style Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.eu