Résumé du contenu de la page N° 1
Ventless Hood System
MODEL FH-28
Installation & Operation Manual
Serial Numbers 123046 and higher
Résumé du contenu de la page N° 2
Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the original purchaser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship. Written notice of a claim under this warranty must be received by the Company within ONE YEAR from the date of installation, but no longer than ONE YEAR AND THREE MONTHS from date of shipment from the factory. Defective conditions caused by abnormal use or misuse, la
Résumé du contenu de la page N° 3
Ventless Hood System Table of Contents Table of Contents Table of Contents........................................................................................................................................1 Introduction .................................................................................................................................................2 Safety Precautions....................................................................................................
Résumé du contenu de la page N° 4
Ventless Hood System Introduction Introduction Congratulations! You have chosen BKI’s Ventless Hood system, a state-of-the-art unit that filters grease laden air and returns it to the room. The BKI name and trademark on this unit assures you of the finest in design and engineering -- that it has been built with care and dedication -- using the best materials available. Attention to the operating instructions regarding proper operation, installation and maintenance will result in long
Résumé du contenu de la page N° 5
Ventless Hood System Introduction Specific Precautions Carbon monoxide poisoning will result from using this hood with any appliance that utilizes combustible fuel. Use only electrical appliances with this hood. In the event of an appliance fire, serious injury, property damage or death could occur if the appliance is not properly secured to the hood. A restraining device has been provided to assure that the appliance remains in the proper position under the hood during normal
Résumé du contenu de la page N° 6
Ventless Hood System Introduction Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your equipment. Keep all safety labels clean and in good condition. Replace any damaged or missing safety labels. If you need new safety labels, contact: BKI Technical Services Department P.O. Box 80400 Simpsonville, S.C. 29680-0400 Or call toll free: 1-800-927-6887 Outside the U.S., call 864-963-3471 Prepare for Emergencies Be prepared
Résumé du contenu de la page N° 7
Ventless Hood System Introduction UL Information Failure to adhere to building, fire and electrical codes during installation of this unit could result in death, serious injury or property damage. The authority having jurisdiction, such as the local building inspector or fire marshal, should be consulted prior to installation to insure compliance with applicable codes. In the event of an appliance fire, serious injury, property damage or death could occur if the appliance is po
Résumé du contenu de la page N° 8
Ventless Hood System Introduction Fryers Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 60 Maximum Input 22 KW (3ph) 14.4 KW (1ph) Frequency 60 Hz Maximum normal frying temperature 375° F. (191° C.) Maximum shortening capacity 110 lbs. (50kg.) Maximum cooking surface area 396 sq. in. (2555 sq. cm.) USE ELECTRIC FRYERS AND SINGLE VAT FRYERS ONLY Griddles Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 38.5 Maximum Input 8 KW Frequency 60
Résumé du contenu de la page N° 9
Ventless Hood System Operation Operation Principle of Operation A blower inside the ventless hood draws cooking vapors through a grease baffle. Inside the baffle, the air reverses direction two times capturing particles of moisture, grease, and dirt. Material collecting on the baffle drains into the condensation trough located below the baffle. After air passes through the baffle, it then enters a specially designed, high efficiency particle/odor filter where any particles that may have
Résumé du contenu de la page N° 10
Ventless Hood System Operation Shut-Down Power to the appliance is turned off, when the hood is turned off. For proper operation, always turn off appliance and allow time for it to cool before turning off the filter hood. This will insure proper capture of grease vapors. To stop the Filter Hood, press the “STOP” button. When to Replace the Filter The particle/odor filter should be replaced when the CHANGE FILTER light illuminates. In low to medium volume applications, the
Résumé du contenu de la page N° 11
Ventless Hood System Installation Installation Unpacking and Handling Inspection for Shipping Damage YOU are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage to cartons or pallets is found, or if a shortage is found, note this on the bill of lading (all copies) prior to signing and receiving. If damage is found when the equipment is opened, immediately call the delivering truck line a
Résumé du contenu de la page N° 12
Ventless Hood System Installation Leveling 1. Adjust the four feet provided on the bottom of the unit so there is a minimum of 6” clearance below the frame side members (NSF/UL REQUIREMENTS). 2. Check for level from side to side and front to back using a 4’ level placed appropriately on the frame. 10
Résumé du contenu de la page N° 13
Ventless Hood System Installation Securing Wall Mount After the hood has been located and leveled, secure to building by utilizing the .437 diameter holes provided in the rear of the fire extinguisher cylinder shelf (Refer to figure below). Using 1/4” lag screw(s), spacer(s) (if required), and anchor(s) (if required) secure the hood to a wall to prevent movement. The outside holes are spaced at 16 inches in the event wall studs can position the unit. Brace Mount If the unit is be
Résumé du contenu de la page N° 14
Ventless Hood System Installation Assembly and Mounting Fire Damper A UL Listed 165° F fusible link must be installed in the damper assembly located at the top of the unit. Install as follows: 1. Lift the damper. 2. Place the link on the damper hook. 3. Lower the damper while placing the link onto the stationary hook. Air Deflector Mount air deflector, as shown in the figure below, using two knurled screws (provided). 12
Résumé du contenu de la page N° 15
Ventless Hood System Installation Particle/Odor Filter 1. Remove the filter from the plastic bag. 2. Open the filter door on the front of the unit by rotating the handle counter-clockwise. 3. Observing the “UP” arrows on the filter, with a hand at each front corner, carefully slide the filter into the unit. 4. Close and latch the door. Appliance Stop FB37144203 (Used with BKI Automatic Lift Fryers) The Appliance Stop must be installed if a BKI Automatic Lift Fryer with M0084
Résumé du contenu de la page N° 16
Ventless Hood System Installation Appliance Restraining Device Install appliance-restraining device as shown in the figure below. In the event of an appliance fire, serious injury, property damage or death could occur if the appliance is not secured to the hood. A restraining device has been provided to assure that the cooking appliance remains in the proper position under the hood during normal operation. DO NOT REMOVE THE RESTRAINING DEVICE! Adjust restraining cable to allow no
Résumé du contenu de la page N° 17
Ventless Hood System Installation Fire Extinguishing System In the event of an appliance fire, serious injury, property damage or death could occur if any part of the appliance obstructs the spray nozzles. Ensure that lids and/or other parts of the appliance do not obstruct the spray pattern of either nozzle. The fire extinguishing system components used in this hood have been evaluated by U.L. in the course of their classification for use on this hood. An authorized Range
Résumé du contenu de la page N° 18
Ventless Hood System Installation 3. If required, connect the provided fire extinguishing system contacts for remote signaling (refer to the electrical diagram in this manual). 4. Adjust the position of the two ADP appliance nozzles as depicted below. 5. Reset control head. With control head NOT connected to cylinder, dry test system by activating the remote pull. 6. Install cylinder by placing bottom of cylinder over socket head screws at the bottom of cylinder bracket.
Résumé du contenu de la page N° 19
Ventless Hood System Installation The fire extinguishing system must be operative before the electrical system will function. Refer to the electrical diagram included in attached to this unit or in the service manual. Standard Electrical Connection This connection is for UL listed appliances supplied with a cord and a NEMA style 15-60 right angle plug. 1. Remove fire extinguisher access panel. 2. Route incoming power lines through holes located in the top of the 12”x8”x4” el
Résumé du contenu de la page N° 20
Ventless Hood System Installation 18