Résumé du contenu de la page N° 5
Notice Regarding removing or replacing a battery in the circuit board, consult your dealer. For users in Finland, Norway and Sweden only This unit may only be installed in a room or space with restricted access, and equipotential bonding must be applied. For information on earthing, refer to "2.7 Connecting Frame Earth". WARNING • THIS UNIT MAY ONLY BE INSTALLED AND SERVICED BY QUALIFIED SERVICE PERSONNEL. IF DAMAGE TO THE UNIT EXPOSES ANY INTERNAL PARTS, DISCONNECT THE POWER SUPPLY COR
Résumé du contenu de la page N° 6
Precautions for Users in the United Kingdom FOR YOUR SAFETY, PLEASE READ THE FOLLOWING TEXT CAREFULLY. This appliance is supplied with a moulded three-pin mains plug for your safety and convenience. A 5 amp fuse is fitted in this plug. Should the fuse need to be replaced, please ensure that the replacement fuse has a rating of 5 amps and that it is approved by ASTA or BSI to BS1362. Check for the ASTA mark or the BSI mark on the body of the fuse. If the plug contains a removable fuse cove
Résumé du contenu de la page N° 7
How to replace the fuse: Open the fuse compartment with a screwdriver and replace the fuse and fuse cover. The equipment must be connected to direct extension lines, and a payphone should not be connected as an extension. 999 and 112 can be dialled on the apparatus after accessing the Exchange line for the purpose of making outgoing calls to the BT emergency services. During dialling, this apparatus may tinkle the bells of other telephones using the same line. This is not a fault and w
Résumé du contenu de la page N° 8
Table of Contents 1 Before Installation ..................................................................................9 1.1 Unpacking..........................................................................................................................9 1.2 System Connection Diagram .........................................................................................10 2 Installation.............................................................................................11 2.1 Ope
Résumé du contenu de la page N° 9
1 Before Installation 1.1 Unpacking Check the package contents. Main Unit × 1 CD-ROM (including manuals, etc.) × 1 *AC Cord × 1 Screw × 3 Washer × 3 Mini Plug (for pager and music Strap × 1 source) × 2 * The type of the AC cord may vary depending on the country/area of use. More than one type of AC cord may be included for countries/areas in Central and South America. Necessary tools (not supplied): Telephone cable for extension connection: Diameter of cable Maximum length of cable (ø 0.4 mm t
Résumé du contenu de la page N° 10
1.2 System Connection Diagram Outside (CO) Line Remote PC External audio source (radio, CD player, etc.) Paging system (loudspeaker, amplifier and speaker, etc.) Batteries SLT PT Door Opener/ Doorbell/Door Chime Fax/Telephone Answering Machine Doorphone DSS Console PC Wireless Phone Voice Processing Printer PC System Connect a display-equipped proprietary telephone (PT) to extension jack 01, as this extension is automatically designated as the manager extension. For supported extension
Résumé du contenu de la page N° 11
2 Installation 2.1 Opening Covers 1. Pull the slide button to the right and, holding it, slide the cable cover upwards. Then turn the cable cover slightly to remove it. Slide Button Cable Cover 2.2 Connecting Outside (CO) Lines 1. Insert the modular plugs of the telephone line cords (2-conductor wiring) into the outside (CO) line jacks. 2. Connect the line cords to the terminal board or the modular jacks from the telephone company. TEL Jack for Outside(CO)Line R T T: Tip R: Ring To Terminal Bo
Résumé du contenu de la page N° 12
2.3 Connecting Extensions Extension jacks can be used for proprietary telephones (PTs), Direct Station Selection (DSS) Consoles, single line telephones (SLTs), and Voice Processing Systems. Notes Connect a display-equipped proprietary telephone (PT) to extension jack 01, as this extension is automatically designated as the manager extension. *1 For KX-TEB308, 4 extension jacks out of 8 can be used for SLTs only. The following table shows the extension jack types. Extension Jack Types TEA3
Résumé du contenu de la page N° 13
2.4 Securing the Cables 1. Attach the included strap to either of the 2 rails depending on your preference. Rail Rail 2. Bind the cables as shown. Getting Started 13
Résumé du contenu de la page N° 14
2.5 Closing Covers 1. Attach the rear hooks on the cable cover to the main unit, then swing the cable cover closed so that the front hooks fit in place. Cable Cover 2. Slide the cable cover down until it locks. Note For safety reasons, keep the front cover closed while the PBX is in operation. 14 Getting Started
Résumé du contenu de la page N° 15
2.6 Wall Mounting The PBX is designed for wall mounting only. The wall where the PBX is to be mounted must be able to support the weight of the PBX. When wall mounting the main unit, use either the included screws, or screws of the same size. 2.6.1 Mounting on a Wooden Wall The included screws may be used when mounting the main unit on a wooden wall. 1. Place the template (found on the last page of this manual) on the wall to mark the 3 screw positions. 120 mm 232 mm Template 2. Fit the wash
Résumé du contenu de la page N° 16
Notes Do not block the openings of the cabinet. Leave at least 20 cm of space above and 10 cm to the sides of the PBX for ventilation. Make sure that the wall behind the cabinet is flat and free of obstacles, so that the openings on the back of the cabinet will not be blocked. Be careful not to drop the cabinet. 2.6.2 Mounting on a Concrete or Mortar Wall The included screws may be used when mounting the main unit on a concrete or mortar wall. User- supplied anchor plugs are also necessa
Résumé du contenu de la page N° 17
4. Affix the PBX to the screw heads. Notes Do not block the openings of the cabinet. Leave at least 20 cm of space above and 10 cm to the sides of the PBX for ventilation. Make sure that the wall behind the cabinet is flat and free of obstacles, so that the openings on the back of the cabinet will not be blocked. Be careful not to drop the cabinet. 2.7 Connecting Frame Earth IMPORTANT Connect the frame of the PBX to earth. 1. Loosen the screw. 2. Insert an earthing wire (user-supplied)*.
Résumé du contenu de la page N° 18
Be sure to comply with all applicable laws, regulations, and guidelines. Proper earthing is very important to protect the PBX from external noise and to reduce the risk of electrocution in the event of a lightning strike. The AC cable's earthing pin may not be enough to protect the PBX from external noise and lightning strikes. A permanent connection must be made between earth and the earth terminal of the main unit. 18 Getting Started
Résumé du contenu de la page N° 19
3 Starting the Advanced Hybrid System 3.1 Starting the Advanced Hybrid System This section explains the procedure for starting the PBX for the first time, with default values, or when you wish to re-initialise the PBX. 1. Make sure that all outside (CO) lines you use are connected to the PBX. 2. Set the Power Switch to the "OFF" position. 3. Connect the AC cord to the PBX, then plug the AC cord into an AC outlet. 4. Set the Power Switch to the "ON" position. Note For safety reasons, do not stre
Résumé du contenu de la page N° 20
CAUTION The PBX is powered as long as the AC cord is plugged into an AC outlet, even if the Power Switch is set to the "OFF" position. The power supply cord is used as the main disconnect device. Ensure that the AC outlet is located/installed near the equipment and is easily accessible. Notes If the outside (CO) lines you use are not connected to the PBX, outside (CO) line type can not be automatically detected. Use only the AC cord included with the PBX. If the PBX will not be used
Résumé du contenu de la page N° 1
Advanced Hybrid System
Getting Started
KX-TEA308
Model KX-TEB308
Thank you for purchasing a Panasonic Advanced Hybrid System.
Please read this manual carefully before using this product and save this manual for future use.
Résumé du contenu de la page N° 2
System Components System Components Table Model Description Main Unit KX-TEA308 Advanced Hybrid System: 3 Outside (CO) Lines, 8 Hybrid Extensions KX-TEB308 Advanced Hybrid System: 3 Outside (CO) Lines, 4 Hybrid *1 and 4 SLT Extensions Optional Service Cards KX-TE82460 2-Port Doorphone Card KX-TE82492 2-Channel Voice Message Card (for KX-TEA308 only) KX-TE82493 3-Port Caller ID Card Proprietary Equipment KX-T30865 Doorphone KX-A227 Backup Battery Cable *1 Taiwan: 4 PT Extensions For supported
Résumé du contenu de la page N° 3
Important Safety Instructions When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Read and understand all instructions. 2. Follow all warnings and instructions marked on the product. 3. Unplug the product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Clean with a damp cloth. 4. Do not use this product near water, for example,
Résumé du contenu de la page N° 4
16. Keep the unit away from heating appliances and devices that generate electrical noise such as fluorescent lamps, motors and televisions. These noise sources can interfere with the performance of the PBX. ˚C 17. This unit should be kept free of dust, moisture, high temperature (more than 40 ) and vibration, and should not be exposed to direct sunlight. 18. If you are having problems making calls to outside destinations, follow this procedure to test the outside (CO) lines: 1. Disconnect t