Résumé du contenu de la page N° 1
CASSETTE TYPE AIR CONDITIONER
Operation & Installation
Manual
AB212XCEAA
No.0010577706
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
Résumé du contenu de la page N° 2
Contents Cautions ............................................................................................. 1-4 Introduction to Spare Parts................................................................... 5 Maintenance....................................................................................... 6-8 Trouble Shooting ............................................................................. 9-10 When Trouble Happens................................................................
Résumé du contenu de la page N° 3
Cautions Disposal of the old air conditioner Consult your local authorities for the name and address of the waste materials collecting Before disposing an old air conditioner centers and waste paper disposal services that goes out of use, please make sure it's nearest to your house. inoperative and safe. Unplug the air conditioner in order to avoid the risk of Safety Instructions and Warnings child entrapment. Before starting the air conditioner, read the It must be noticed that air conditioner
Résumé du contenu de la page N° 4
Cautions All electrical repairs must be carried out 4. The wiring method should be in line with by qualified electricians. Inadequate repairs the local wiring standard. may result in a major source of danger for the user of the air conditoiner. 5. The power cable and connecting cable are self-provided. Do not damage any parts of the air All the cables shall have got the Local conditioner that carry refrigerant by authentication certificate. piercing or perforating the air conditioner's tub
Résumé du contenu de la page N° 5
Cautions Safety cautions Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. INSTRUCTIONS: These information can ensure the correct operation of the machine. Be sure to conform with t
Résumé du contenu de la page N° 6
Cautions CAUTIONS! Don't operate the air-con- Conditioner should not be used for any other ditioner with damp hands. purpose other than airconditioning. Don't use air-conditioner for any other special Otherwise will be shocked. purposes, e.g. the preservation and protection Only use correctly-typed fuse. of food, animals, plants, May not use wire or any other pecision apparatus as well materials replacing fuse, other- as work of art, otherwise wise may cause faults or fire the qualities of th
Résumé du contenu de la page N° 7
Introduction to Spare Parts Discharge unit (built in) In cooling operation, Drain Hose to discharge the water from inside the room. Swing fender (located in the outlet) Refrigerant pipe Outlet Cable line Earthing line Air filter (located in the suction grill) Suction grill 5
Résumé du contenu de la page N° 8
Maintenance (B) Wash with water. [Clean air filter] With too much dust, use soft brush and neutral When having to clean, don't dismantle NOTE detergent. air-filter,otherwise may cause faults. Swing off the water, and then place in cool place. In the environment where there is too much dust, air filter should be cleaned for more times. (about half a year one time) 1. Open inlet grill 5. Install air filter Press the elliptical "PUSH" knob, the inlet (1) Put filter into protruding parts
Résumé du contenu de la page N° 9
Maintenance 2. Take off air-filter 3. Take of inlet grill [Dismantle and install swing plate ] 1. Fix the swing plate at the bottom. 2. Dismantle the swing plate. CAUTION! 4. Clean Use water to clean the plate and don't heavily CAUTION! scrub, otherwise the fine hair may fall off. Unscrew the screw at both ends of the swing plate. NOTE [Dismantle and install swing When the filter too much dust plate ] To spray the special detergent for vent fan or 3. Install swing plate utensils. Lightly rotate
Résumé du contenu de la page N° 10
Maintenance Seasonal Reserve Post-season Care Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat. Pre-season Care See that there is no obstacles blocking the air inlet and air outlet of both indoor and outdoor unit to avoid reduce the working effic
Résumé du contenu de la page N° 11
Trouble Shooting The followings are not malfuncition When the air conditoner is started, when the Water flowing sound is heard compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is Hua the flowing sound of the refrigerant , not a Hua malfunction. This is caused by heat expansion or contra- Cracking sound is heard ction of plastics Air blown out from the indoor unit sometimes It smells. smells. The smell results f
Résumé du contenu de la page N° 12
Trouble Shooting Air does not blow or the fan speed cannot be In DRY mode, when room temperature changed during drying. becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting This happens when the frost accumulated on Water or vapor generated from the outdoor the outdoor unit is removed (during defrosting unit during heating. operation). Defrosting operation To get ride of the excess heat, indoor fan will During heating,indoor fan is still
Résumé du contenu de la page N° 13
When Trouble Happens Insufficient cooling or heating The operation controller Air filter too dirty ? Horizontal swing louver adjusted as required upward ? (in HEAT mode) Any obstacle exists at the air Door or window left opened ? inlet or outlet? Insufficient cooling Too crowed in the room ? Sunlight direct into the Any other heat sources in the room ? room? Cooled air blown out ( when heating) When the air conditioner does not operate properly after you have checked the above-mentioned items or
Résumé du contenu de la page N° 14
Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place. After installation ,please use the air conditioner according to the specification in the operation manual. Using Directions Avoid dir
Résumé du contenu de la page N° 15
Installation Procedure Installation Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. WARNING ! Please call dealer to install the air-conditioner. Incorrect installation may cause water leaking, shock and fire hazard. CAUTION ! Air-conditioner can't be installed in the envi- Connect earthing wire. ronment with inflammable gases because the Earthing wire should not be con- inflammable gases near to
Résumé du contenu de la page N° 16
Installation Procedure To ensure proper installation, read "Cautions" carefully before working. After CAUTIONS: installation, start the unit correctly and show customers how to operate and maintain the unit. Meanings of Warning and Cautions: Warning! Serious injury or even death might happen, if it is not observed. Caution! Injury to people of damages to machine might happen, if it is not observed. WARNING! Installation shall be done by professional people, don't install unit by yourself. Incorr
Résumé du contenu de la page N° 17
Installation Procedure Installation tools The installation tools listed in the following sheet can be used as required. 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 11. Band tape 12. Scraper 13. Refrigerant oil 1 1. BEFORE INSTALLATION Determine the way to carry unit to inst
Résumé du contenu de la page N° 18
Installation Procedure 3 3. PREPARATION FOR THE INSTALLATION (1) Position of ceiling opening between unit and suspending bolt. Refrigerant pipe Suspending bracket Suspending bolts Ceiling >20 A A (Distance between suspending bolts) 840(Indoor unit) 890(Ceiling opening) 950(Ornament panel) A (2) Cut an opening in ceiling for installation if necessary. (when ceiling already exists.) Refer to paper pattern for dimension of ceiling hole. Connect all pipings (refrigerant, water drainage), wirings (
Résumé du contenu de la page N° 19
Installation Procedure 4 4. INSTALLATION OF INDOOR UNIT In the case of new ceiling (1) Install unit temporally Put suspending bracket on the suspending bolt. Be sure to use nut and washer at both ends of the bracket. (2) As for the dimensions of ceiling hole, see paper pattern. Ask your real estate dealer for details. Center of the hole is marked on the paper pattern. Center of the unit is marked on the card in the unit and on the paper pattern. 5 6 Mount paper
Résumé du contenu de la page N° 20
Installation Procedure 5 5. REFRIGERANT PIPING (As for outdoor piping, please refer to installation Manual of outdoor unit.) Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to Table 1. Apply refrigerant oil at both inside and outsid of lflare nut. Tighten it band tight 3-4 turns then tighten it. Use torque specified in Table 1. (Too much force may damage flare nut, causing gas leakage).