Résumé du contenu de la page N° 1
Installation and
Maintenance
Manual
The CE Marking on this equipment indicates
Compliance with the following
This device conforms to Directive 1999/5/EC on
Radio Equipment and Telecommunications
Terminal Equipment as adopted by the
European Parliament And Of The Council
BT Versatility
Offices Worldwide
The telecommunications services described in this publication
are subject to availability and may be modified from time to time.
Services and equipment are provided subject to British
Commu
Résumé du contenu de la page N° 2
BT Versatility Installation and maintenance Manual Contents Introduction 2 Cabling the unit 31 General overview 2 Connecting the extensions 31 Safety Precautions during installation and CCU connections 33 system upgrades 3 Door Intercom 33 Electrostatic precaution (ESP) 3 Doorstrike 33 Lightning and surge voltage protection 3 Connecting a MOHI unit 36 Installation checklist 6 Connecting a PA 37 Installing the Central Control Unit
Résumé du contenu de la page N° 3
BT Versatility Installation and maintenance Manual Introduction This document describes the practices to be adopted by field engineers during installation and maintenance of the BT Versatility. A more detailed description of the product, along with customer programmable facilities and features, may be found in the BT Versatility Owner's Manual, which should be read in conjunction with this document. General overview • The BT Versatility is a new converged PBX and Data product, which ca
Résumé du contenu de la page N° 4
BT Versatility Installation and Maintenance Manual Safety Precautions during installation and system upgrades Always unplug or isolate the mains supply when installing or upgrading the system. After installing the central control unit (CCU) and all required modules, ensure that the following points are checked before switching the mains power on: • The cabled extensions have a DTMF telephone or a (V8/V16) Featurephone connected. • The CCU cover is in place and locked. Aft
Résumé du contenu de la page N° 5
BT Versatility Installation and maintenance Manual BT Versatility - Packages, Spares and Maintenance Items BT Code BT Versatility Pro. Plus(Includes System, VM, 1M,2V8) BT Vers Pro Plus 2+8 Digital VDS 007193 BT Vers Pro Plus 4+16 Digital VDS 007194 BT Vers Pro Plus 6+24 Digital VDS 007195 BT Vers Pro Plus 8+32 Digital VDS 007196 BT Versatility Advanced Digital (System, 8 Port VM Pro , 4V8 and V16 with the 12/32 ) N/A BT Vers Adv 2+8 Dig VDS 017672 BT Vers Adv 6+16 Di
Résumé du contenu de la page N° 6
BT Versatility Installation and Maintenance Manual BT Versatility 8 Port Extension Module VDS 007225 BT Versatility Hospitality Application VDS 007226 BT Versatility Options Module VDS 007227 BT Versatility V Telephone VDS 007228 BT Versatility V8 Featurephone 007229 BT Versatility V16 Featurehone VDS 007230 BT Versatility V16 XP Expansion Console VDS 007231 BT Versatility Door Intercom VDS 007232 BT Versatility Expansion Backplane VDS 007233 BT Vers V/email Pro 8P VDS 017691
Résumé du contenu de la page N° 7
BT Versatility Installation and maintenance Manual BT Versatility Options MDF MTC 007261 BT Versatility Mod Retentn Long 1/4 turn Screw MTC 007262 BT Versatility V16 Console to V16 Connection Cable MTC 007263 BT Versatility V16 PSU MTC 007264 BT Versatility PSTN Module MTC 007265 BT Versatility ISDN2 Module MTC 007266 BT Versatility Voice Mail Module 2 Port MTC 007267 BT Versatility Voice Mail Module 4 Port MTC 007268 BT Versatility Battery Backup Module MTC 007269 BT Versat
Résumé du contenu de la page N° 8
BT Versatility Installation and Maintenance Manual Installing the Central Control Unit CCU Location(CCU) The CCU is intended for installation in a residential or office-type environment. It needs to be mounted at a convenient working height on a dry, flat wall. The normal height is 1.5 m from the floor to the bottom of the CCU case. Do not site the CCU where it will be subjected to excessive levels of heat, dust, damp or high humidity. Locating the equipment near sources of electroma
Résumé du contenu de la page N° 9
BT Versatility Installation and maintenance Manual CCU Mounting bracket clearances The main unit is mounted on a wall using the bracket supplied and should have top and side clearance as shown below. CCU Mounting Bracket 300mm If the system is to be equipped with a Ports, Options or Internet module then two mounting brackets need to be installed. CCU Bracket + Backplane Bracket 300mm min 300mm min
Résumé du contenu de la page N° 10
BT Versatility Installation and Maintenance Manual Mounting the CCU The CCU is mounted on the bracket by sliding it on from the left hand side. The marks on the side of the CCU must be lined up with the flanges on the wall bracket as shown below before sliding the CCU into place. When you slide it fully to the right-hand side of the bracket the CCU is automatically locked in place. 300mm min line marks up Flanges with flanges To remove
Résumé du contenu de la page N° 11
BT Versatility Installation and maintenance Manual Modules located in the CCU There are a number of modules that can be installed in the CCU. • Analogue Line Module (Coloured Black). This provides 2 Analogue exchange lines. Up to two of these modules can be installed in the CCU to provide two or four Analogue lines. • Digital Line Module (Coloured Red). This card provides one ISDN 2 Basic Rate Interface. The same module is used for the network T interface and the internal S-bus. U
Résumé du contenu de la page N° 12
BT Versatility Installation and Maintenance Manual System Expansion To equip the switch with more than 8 extensions or to add an Internet or Options module, a backplane, mounted on a second wall bracket, is needed. The power must be disconnected to install the backplane or expansion modules. Installing the Backplane wall bracket The CCU and Backplane brackets are identical. However when both are installed the backplane bracket is inverted so that it meshes closely with the CCU brac
Résumé du contenu de la page N° 13
BT Versatility Installation and maintenance Manual Mounting the Backplane Slide the backplane on from the right hand side. Ensure the connector is fully mated with the CCU. Securing the backplane to the wall bracket A mounting screw is used to securely locate the backplane on the wall bracket. This provides additional rigidity to ensure the backplane and CCU connectors do not move. Remove the fourth and fifth cover from the backplane.Locate the backplane on
Résumé du contenu de la page N° 14
BT Versatility Installation and Maintenance Manual Expansion Modules There are three types of expansion module that can be installed on the back plane. These are the Ports Module, the Internet Module and the Options Module. All these modules are installed in the same way. Modules are supplied in two parts. The MDF, which is connected to the backplane, and the module which is inserted into the MDF. The Ports MDF is also equipped with two connectors for the Analogue and /or the ISDN B
Résumé du contenu de la page N° 15
BT Versatility Installation and maintenance Manual Installing an Expansion module Install the Backplane as described on page 12. Install the MDF in the first free left-hand slot on the backplane. Lock the MDF in place by pushing the lock bar upward using a screwdriver. Push up to lock Lift the MDF cover and install the module. 14
Résumé du contenu de la page N° 16
BT Versatility Installation and Maintenance Manual Analogue line module The Analogue Line module contains circuitry for 2 Analogue Lines. The module is coloured BLACK and it can be installed in the CCU and also on the Ports MDF. Analogue Module Installing the Analogue Module in the CCU Remove the cover of the CCU. Insert the Analogue module in the Network slot or slots in the CCU. The left -hand slot is the first module position Remove the cover. Lo
Résumé du contenu de la page N° 17
BT Versatility Installation and maintenance Manual To Locate the Analogue Module in the Ports Module: Remove the Ports Module by firstly opening the Ports MDF cover Open the Ports module and remove it from the MDF Insert the Analogue Module (or modules) on the MDF connectors The upper slot is the first module position First network module 16
Résumé du contenu de la page N° 18
BT Versatility Installation and Maintenance Manual Basic Rate ISDN expansion module The ISDN Basic Rate Module provides one Basic Rate ISDN circuit (2B+D). The module is coloured RED, and can be installed in the CCU and also in the Ports MDF. Installing the Basic Rate ISDN Module in the CCU Remove the cover of the CCU as shown. Insert the Basic Rate ISDN module in the Network slot or slots in the CCU as shown: Digital Line Module (ISDN 2) First network
Résumé du contenu de la page N° 19
BT Versatility Installation and maintenance Manual To Locate the Digital Line Module (ISDN 2) in the PORTS module Remove the Ports Module by firstly opening the Ports MDF cover Open the Ports module and remove it from the MDF Insert the Digital Line Module (or modules) on the MDF connectors The upper slot is the first module position The top connector is for the first module that connects to the Network only. The lower connector is for the second module. This can be an ISDN 2 Netwo
Résumé du contenu de la page N° 20
BT Versatility Installation and Maintenance Manual System ISDN settings The system can be configured with 8 Basic Rate ISDN interfaces. Half of these can be configured for internal S-bus operation. The second interface on the CCU and each of the Ports Modules can be programmed as S-bus interfaces for ISDN to-the-desk. T interface termination 0 An ISDN bus must be terminated twice, once at the start and once at the end of the bus. The Network Terminating Equipment (NTE) will provide t