Résumé du contenu de la page N° 1
Product Description
Model EIR505-xx
Documentation Number: EIR505-xx_5107m
707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA
Phone (815) 433-5100 -- General Fax (815) 433-5105
Phone (815) 433-5100 -- General Fax (815) 433-5105
Website: www.bb-elec.com
Sales e-mail: orders@bb-elec.com -- Fax (815) 433-5109
Technical Support e-mail: support@bb.elec.com -- Fax (815) 433-5104
European Headquarters
B
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
Five Port Managed Industrial Ethernet Switches User Manual Manual Documentation Number: EIR505-xx_5107m Table of Contents iii B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Résumé du contenu de la page N° 4
Notice The contents of this manual are based on the firmware, kernel, and hardware versions listed below. Firmware Version V1.29 Kernel Version V2.05 A5.00 Hardware Version B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Résumé du contenu de la page N° 5
FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
Résumé du contenu de la page N° 6
Content FCC Warning............................................................ v CE Mark Warning..................................................... v Introduction................................................................ 1 Features ................................................................... 1 Package Contents.................................................... 2 Hardware Description................................................ 3 Physical Dimension....................
Résumé du contenu de la page N° 7
DIN-Rail Mounting.................................................. 11 Wall Mount Plate Mounting .................................... 13 Hardware Installation............................................... 14 Network Application ................................................ 15 X-Ring Application.................................................. 15 Coupling Ring Application ...................................... 16 Dual Homing Application........................................ 17 Web
Résumé du contenu de la page N° 8
Port-based VLAN .............................................................25 802.1Q VLAN ...................................................................27 IP Address.............................................................. 31 SNTP Configuration ............................................... 32 IP Security.............................................................. 35 RSTP Configuration ............................................... 36 System Configuration ................
Résumé du contenu de la page N° 9
Troubles shooting.................................................... 50 Technical Specification........................................... 51 Manual Documentation Number: EIR505-xx_5107M Table of Contents ix B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Résumé du contenu de la page N° 10
Résumé du contenu de la page N° 11
Introduction The Elinx EIR505 series of Industrial Managed Ethernet Switches provide powerful functionality in a small package. Designed for industrial applications, these switches are highly reliable. Features Conforms to IEEE 802.3 10Base-T, 802.3u 100Base-TX/100Base-FX 5-port 10/100TX industrial switch (Fiber Optic models have 1 100FX port) RJ-45 ports support auto MDI/MDI-X Store-and-Forward switching architecture Wide-range redundant input power connections DIN rail a
Résumé du contenu de la page N° 12
Package Contents 5 Port Managed Industrial Switch One DIN-Rail (attached to the switch) One Panel mount plate and six screws User manual 5 10/100TX with X-Ring Web Management User Manual Industrial switch Wall Mount Plate Screws DIN-Rail If any item is missing or damaged, contact B&B Electronics for a replacement. 2 Manual Documentation Number: EIR505-xx_5107m B&B Electronics Mf
Résumé du contenu de la page N° 13
Hardware Description Physical Dimension (W x H x D) 2.13in x 5.31in x 4.13 in (54mm x 135mm x 105mm) Front Panel EIR505 Front Panel Reset Button The reset button is used to restart the reboot the switch or restore it to the factory default configuration. Restart: Press the button for 2 seconds and release. Set to factory default value: Press the button for 5 seconds and release. Manual Documentation Number: EIR505-xx_5107m 3 B&
Résumé du contenu de la page N° 14
Bottom View The bottom panel of the EIR-505-xx industrial switch consists of one terminal block connector with two DC power inputs and one DC IN power jack. Bottom Panel of the industrial switch DIP-switch The six position DIP-switch is used to configure the relay alarm operation mode and the master ring operation mode. The default value for each position is OFF. DIP Switch No Status Description OFF Disable port 1 Alarm 1 ON Enable port Alarm. 2 OFF Disable port Alar
Résumé du contenu de la page N° 15
ON Enable port Alarm. OFF Disable port Alarm 3 ON Enable port Alarm. OFF Disable port Alarm 4 ON Enable port Alarm. OFF Disable port Alarm 5 ON Enable port Alarm. OFF Disable the master ring function. 6 Enable the switch as the ring master ON in the X-Ring group. LED Indicators There are 7 diagnostic LEDs located on the front panel. They provide real-time status information. LED Status Meaning Power Green The switch is on Manual Documentation Number: EIR505-xx_510
Résumé du contenu de la page N° 16
The switch is off or no power input Off is available The switch is the master of X-Ring Green group R.M. (Ring Master) The industrial switch is not the Off master of an X-Ring group Green Power source 1 is available Power 1 Off Power source 1 is not available Green Power source 2 is available Power 2 Off Power source 2 is not available Yellow Power failure or port failure Fault Off Normal Operation Green The port is linked LNK/ACT (port 5) Blinking The port is transmitti
Résumé du contenu de la page N° 17
RJ-45 Pin Assignments Pin Number Assignment 1 Tx+ 2 Tx- 3 Rx+ 6 Rx- All ports on this switch support automatic MDI/MDI-X operation. Straight-through cables can be used for all network connections. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table below shows the 10BASE-T/100BASE-TX MDI and MDI-X port pin outs. Pin MDI-X Signal Name MDI Signal Name 1 Receive
Résumé du contenu de la page N° 18
Cross Over Cable Schematic Fiber Port There is one 100Base-FX port. The fiber port is SC type connector in multi mode (2Km) or single mode (30Km). Connect the fiber port as described below. ATTENTION This is a Class 1 Laser/LED product. Do not stare into the Laser/LED Beam. Cabling Use Category 5 cabling for RJ-45 port connections. The cable must be less than 328 ft (100 meters) long. Use 8/125 or 9/125 um for single-mode fiber. Distances up to 30 8 Ma
Résumé du contenu de la page N° 19
Kilometers are supported. Fuse 50 or 62.5/125 um for multi-mode fiber cable. Distances up to 2Kmare supported. Wiring the Power Inputs V- V+ V- V+ 1. Insert the positive and negative wires into the V+ and V- connector on the terminal block connector 2. Tighten the wire-clamp screws [NOTE] Use 12~ 24 AWG wire. Manual Documentation Number: EIR505-xx_5107m 9 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa
Résumé du contenu de la page N° 20
Wiring the Fault Alarm Contact The fault alarm contact are located in the middle of terminal block connector as shown below. Insert the wires and set the Dipswitch to “ON”. When a power source fails or a link fault occurs, it will be detected and cause an open circuit. The following figure shows an application example for the fault alarm contact. 1A@24V Insert the wires into the fault alarm contact [NOTE] The wire range of terminal block is from 12~ +24 AWG. Fault Alarm C