Résumé du contenu de la page N° 1
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
GS-2124C User's Manual 24 Gigabit L2 Managed Switch Release 0.98 2005, RubyTech Corporation. All rights reserved. All brand and product names are trademarks or registered trademarks of their respective companies.
Résumé du contenu de la page N° 4
The information in this document is subject to change without notice. Unless the explicit written permission of RubyTech Corporation, this document in whole or in part shall not be replicated or modified or amended or transmitted, in any from, or by any means manual, electric, electronic, electromagnetic, mechanical, optical or otherwise for any purpose. DURATION OF HARDWARE WARRANTY HARDWARE: In accordance with the provisions described under, RubyTech Corporation (hereinafter called
Résumé du contenu de la page N° 5
DISCLAIMER. EXCEPT AS PROVIDED ABOVE, THE SOFTWARE IS PROVIDED “AS IS ” AND RUBYTECH AND ITS LICENSORS MAKE NO WARRANTIES, EXPRESS OR IMPLIED, WITH REPSECT TO THE SOFTWARE AND DOCUMENTAITON. RUBYTECH AND ITS LICENSORS DISCLAIM ALL OTHER WARRANTIES, INCLUSIVE OF WITHOUT LIMITATION, IMPLIED WARRANTIES OR MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. FURTHER, RUBYTECH DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE, OR THE RESULTS OF THE US
Résumé du contenu de la page N° 6
Table of Contents CAUTION ------------------------------------------------------------------------------------- VIII ELECTRONIC EMISSION NOTICES -------------------------------------------------------- VIII CHAPTER 1. INTRODUCTION---------------------------------------------------------- 2 1-1. OVERVIEW OF GS-2124C ------------------------------------------------------------ 2 1-2. CHECKLIST------------------------------------------------------------------------------- 4 1-3. FEATU
Résumé du contenu de la page N° 7
3-5. QOS(QUALITY OF SERVICE) CONFIGURATION ----------------------------------- 57 3-6. SNMP CONFIGURATION ------------------------------------------------------------- 67 3-7. IGMP SNOOPING --------------------------------------------------------------------- 69 3-8. MAX. PACKET LENGTH --------------------------------------------------------------- 71 3-9. DHCP BOOT -------------------------------------------------------------------------- 72 3-10. VLAN ---------------------------------
Résumé du contenu de la page N° 8
Revision History Release Date Revision 0.98 06/06/2005 A1 vi
Résumé du contenu de la page N° 9
vii
Résumé du contenu de la page N° 10
Caution Circuit devices are sensitive to static electricity, which can damage their delicate electronics. Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electrical charge. To protect your device, always: • Touch the metal chassis of your computer to ground the static electrical charge before you pick up the circuit device. • Pick up the device by holding it on the left and right edges only. Electronic Emission Notices Federal Commun
Résumé du contenu de la page N° 11
About this user’s manual In this user’s manual, it will not only tell you how to install and connect your network system but configure and monitor the GS-2124C through the built-in CLI and web by RS-232 serial interface and Ethernet ports step-by-step. Many explanation in detail of hardware and software functions are shown as well as the examples of the operation for web-based interface and command-line interface (CLI). Overview of this user’s manual Chapter 1 “Introduction”
Résumé du contenu de la page N° 12
GS-2124C User Manual 1. Introduction 1-1. Overview of GS-2124C GS-2124C, a 24-port Gigabit L2 Managed Switch, is a standard switch that meets all IEEE 802.3/u/x/z Gigabit, Fast Ethernet specifications. The switch included 22-Port 10/100/1000Mbps TP and 2-Port Gigabit TP/SFP Fiber management Ethernet switch. The switch can be managed through RS-232 serial port via directly connection, or through Ethernet port using CLI or Web-based management unit, associated with SNMP agent. With th
Résumé du contenu de la page N° 13
GS-2124C User Manual •••• Key Features in the Device QoS: Support Quality of Service by the IEEE 802.1P standard. There are two priority queue and packet transmission schedule using Weighted Round Robin (WRR). User-defined weight classification of packet priority can be based on either a VLAN tag on packet or a user-defined port priority. Spanning Tree: Support IEEE 802.1D, IEEE 802.1w (RSTP: Rapid Spanning Tree Protocol) and IEEE 802.1s (MST
Résumé du contenu de la page N° 14
GS-2124C User Manual 1-2. Checklist Before you start installing the switch, verify that the package contains the following: GS-2124C 24 Gigabit L2 Managed Switch Modules (optional) Mounting Accessory (for 19” Rack Shelf) This User's Manual in CD-ROM AC Power Cord RS-232 Cable Please notify your sales representative immediately if any of the aforementioned items is missing or damaged. 1-3. Features The GS-2124C, a standalone off-the-shelf switch, provides the
Résumé du contenu de la page N° 15
GS-2124C User Manual • Supports 802.1Q VLAN • Supports user management and limits three users to login • Maximal packet length can be up to 9216 bytes for jumbo frame application • Supports DHCP Broadcasting Suppression to avoid network suspended or crashed • Supports to send the trap event while monitored events happened • Supports default configuration which can be restored to overwrite the current configuration which is working on via web browser and CLI • Supports on-line plug
Résumé du contenu de la page N° 16
GS-2124C User Manual 1-4. View of GS-2124C Fig. 1-1 Full View of 24 Gigabit L2 Managed Switch 1-4-1. User Interfaces on the Front Panel (Button, LEDs and Plugs) There are 24 TP Gigabit Ethernet ports and 2 SFP fiber ports for optional removable modules on the front panel of the switch. LED display area, locating on the left side of the panel, contains a Power LED, which indicates the power status and 24 ports working status of the switch. Gigabit Ethernet Port
Résumé du contenu de la page N° 17
GS-2124C User Manual •••• LED Indicators LED Color Function System LED POWER Green Lit when +5V DC power is on and good CPU LED Green Blinks when CPU is activity 10/100/1000Ethernet TP Port 1 to 24 LED Lit when connection with remote device is good LINK/ACT Green Blinks when any traffic is present Off when cable connection is not good Lit green when 1000Mbps speed is active Green/ Lit ember when 100Mbps speed is active 10/100/1000Mbps Ember Off when 10Mbps speed
Résumé du contenu de la page N° 18
GS-2124C User Manual 1-5. View of the Optional Modules In the switch, Port 23~24 includes two types of media --- TP and SFP Fiber (LC, BiDi LC…); this port supports 10/100/1000Mbps TP or 1000Mbps SFP Fiber with auto-detected function. 1000Mbps SFP Fiber transceiver is used for high- speed connection expansion; nine optional SFP types provided for the switch are listed below: 1000Mbps LC, MM, SFP Fiber transceiver (SFP.0LC.202) 1000Mbps LC, SM 10km, SFP Fiber transceiver (SFP.0LC.
Résumé du contenu de la page N° 19
GS-2124C User Manual 2. Installation 2-1. Starting GS-2124C Up This section will give users a quick start for: - Hardware and Cable Installation - Management Station Installation - Software booting and configuration 2-1-1. Hardware and Cable Installation At the beginning, please do first: ⇒ Wear a grounding device to avoid the damage from electrostatic discharge ⇒ Be sure that power switch is OFF before you insert the power cord to power source •••• Installin
Résumé du contenu de la page N° 20
GS-2124C User Manual • TP Port and Cable Installation ⇒ In the switch, TP port supports MDI/MDI-X auto-crossover, so both types of cable, straight-through (Cable pin-outs for RJ-45 jack 1, 2, 3, 6 to 1, 2, 3, 6 in 10/100M TP; 1, 2, 3, 4, 5, 6, 7, 8 to 1, 2, 3, 4, 5, 6, 7, 8 in Gigabit TP) and crossed-over (Cable pin-outs for RJ-45 jack 1, 2, 3, 6 to 3, 6, 1, 2) can be used. It means you do not have to tell from them, just plug it. ⇒ Use Cat. 5 grade RJ-45 TP cable to connect to a