Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599, Canada (Calgary) 403 274 9391, Canada (Ottawa) 613 233 5949, Canada (Québec) 450 510 3055, Canada (Toronto) 905 785 0085, Canada (Vancouver) 514 685 7530, China 86 21 6555 7838, Czech Republic 420
Résumé du contenu de la page N° 3
Important Information Warranty The NI PXI-1052 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. The media on which you receive National Instruments software are warranted not to fail to execute programming instructions,
Résumé du contenu de la page N° 4
Contents About This Manual Conventions ...................................................................................................................vii Related Documentation..................................................................................................viii Chapter 1 Getting Started Unpacking......................................................................................................................1-1 What You Need to Get Started ................................
Résumé du contenu de la page N° 5
Contents Installing SCXI Modules............................................................................................... 2-10 Installing Optional SCXI-1360 Filler Panels .................................................. 2-10 PXI System Configuration with MAX.......................................................................... 2-10 Basic PXI System Configuration .................................................................... 2-11 Trigger Configuration in MAX.....................
Résumé du contenu de la page N° 6
About This Manual The NI PXI-1052 User Manual contains information about installing, configuring, using, and maintaining the NI PXI-1052 chassis. Conventions The following conventions are used in this manual: » The » symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you t
Résumé du contenu de la page N° 7
About This Manual Related Documentation The following documents contain information that you might find helpful as you read this manual: • DAQ Quick Start Guide SCXI Quick Start Guide DAQ user manuals and installation guides—This documentation has detailed information about the DAQ hardware that plugs into or is connected to the chassis. Use these documents for hardware installation and configuration instructions, specification information about the DAQ hardware, and application hints.
Résumé du contenu de la page N° 8
1 Getting Started This chapter describes the key features of the PXI-1052 chassis and lists the kit contents and optional equipment you can order from NI. Unpacking Carefully inspect the shipping container and the chassis for damage. Inspect the chassis for visible damage to the metal work. Make sure all handles, hardware, and switches are undamaged. Inspect the inner chassis for any possible damage, debris, or detached components. If damage appears to have been caused during shipment,
Résumé du contenu de la page N° 9
Chapter 1 Getting Started Table 1-1. AC Power Cables Power Cable Reference Standards Standard 120 V (USA) ANSI C73.11/NEMA 5-15-P/IEC83 North America 120 V ANSI C73.20/NEMA 5-15-P/IEC83 Switzerland 220 V SEV Universal Euro 230 V CEE (7), II, IV, VII IEC83 Australia 240 V AS C112 United Kingdom 230 V BS 1363/IEC83 If you are missing any of the items in Table 1-1, or if you have the incorrect AC power cable, contact NI through the information given in Appendix C, Technical Support and Professio
Résumé du contenu de la page N° 10
Chapter 1 Getting Started Over-current protection through push-reset circuit breaker (no AC-input fuse to replace) Remote PXI voltage monitoring and inhibit through a rear-panel connector On/Off (Standby) power switch on the front panel for easy access SCXI power switch on the chassis rear panel Front-panel LED that indicates power supply failure Handle for portability Tilt feet for bench-top applications Rack mountable © National Instruments Corporation 1-3 NI PXI-1052 User Ma
Résumé du contenu de la page N° 11
Chapter 1 Getting Started Chassis Description Figure 1-1 and Figure 1-2 show the key features of the PXI-1052 chassis front and rear panels. 1 2 3 4 5 6 7 LV ANALOG HV ANALOG NATIONAL BUS BUS INSTRUMENTS ! SYSTEM SCXI 300V CAT II NI PXI-1052 POWER POWER 17 8 16 15 2 3 4 1 8 9 14 13 12 11 10 8 1 On/Off (Standby) System Power Switch 10 SCXI Module Slots 2 System Power Indicator LED 11 PXI Peripheral Slots 3 SCXI Subsystem Power Indicator LED 12 PXI Star Trigger/Peripheral Slot 4 SCXI Low-Voltag
Résumé du contenu de la page N° 12
Chapter 1 Getting Started 1 2 3 4 1 11 10 9 8 5 1 7 6 1 Filter Retainer Screws 7 Chassis Ground Screw 2 SCXI Subsystem Power Switch 8 Circuit Breaker 3 Remote Inhibit and Voltage Monitoring Connector 9 SCXI Auxiliary I/O Connector 4 Fan Speed Selector Switch 10 SCXI High-Voltage Analog Bus Connector 5Filter Cover 11 SCXI Low-Voltage Analog Bus Connector 6 Universal AC Inlet Figure 1-2. Rear View of the PXI-1052 Chassis Optional Equipment Contact NI to order the following options for the PXI-105
Résumé du contenu de la page N° 13
Chapter 1 Getting Started Interoperability with CompactPCI The PXI-1052 backplane is interoperable with 5 V and universal PXI-compatible products and standard CompactPCI products. This is an important feature because some PXI user systems can require components that do not implement PXI-specific features. For example, you may want to use a standard CompactPCI network interface card in a PXI chassis. The signals on the backplane P1 connectors meet the requirements of the CompactPCI specifica
Résumé du contenu de la page N° 14
Chapter 1 Getting Started Local Bus The PXI backplane local bus is a daisy-chained bus that connects each peripheral slot with adjacent peripheral slots to the left and right as shown in Figure 1-3. For example, the Slot 2 right local bus connects to the Slot 3 left local bus, and so on. The left local bus signal lines on Slot 2 are used for the star trigger and do not connect to Slot 1. The right local bus signal lines on Slot 4 are used for SCXI communication. Each local bus is 13 lines w
Résumé du contenu de la page N° 15
Chapter 1 Getting Started System Reference Clock The PXI-1052 supplies the PXI 10 MHz system clock signal (PXI_CLK10) independently to each peripheral slot. An independent buffer (having a source impedance matched to the backplane and a skew of less than 500 ps between slots) drives the clock signal to each peripheral slot. You can use this common reference clock signal to synchronize multiple modules in a measurement or control system. You can drive PXI_CLK10 from an external source throu
Résumé du contenu de la page N° 16
2 Installation and Configuration This chapter describes how to install, configure, and use the PXI-1052 chassis. Before connecting the chassis to a power source, read this chapter and the Read Me First: Safety and Radio-Frequency Interference document included with the chassis. Safety Information Caution Before undertaking any troubleshooting, maintenance, or exploratory procedure, carefully read the following caution notices. This equipment contains voltage hazardous to human life and safet
Résumé du contenu de la page N° 17
Chapter 2 Installation and Configuration Modification—Do not modify any part of the chassis from its original condition. Unsuitable modifications may result in safety hazards. Chassis Cooling Considerations The PXI-1052 is designed to operate on a bench or in an instrument rack. Determine how you want to use the PXI-1052 and follow the appropriate installation instructions. Providing Adequate Clearance Openings in the top and along both sides of the chassis facilitate power supply and modu
Résumé du contenu de la page N° 18
Chapter 2 Installation and Configuration Tip Install the chassis so that you can access the rear panel easily. This simplifies cleaning or replacing the air filters. Setting Fan Speed The fan-speed selector switch is on the rear panel of the PXI-1052. Refer to Figure 1-2, Rear View of the PXI-1052 Chassis, to locate the fan-speed selector switch. Select HIGH for maximum cooling performance (recommended) or AUTO for quieter operation. The fan speed is determined by chassis intake air tempera
Résumé du contenu de la page N° 19
Chapter 2 Installation and Configuration Connecting Safety Ground Caution The PXI-1052 chassis is designed with a three-position NEMA 5-15 style plug for the United States that connects the ground line to the chassis ground. To minimize shock hazard, make sure the electrical power outlet you use to power the chassis has an appropriate earth safety ground. If the power outlet does not have an appropriate ground connection, you must connect the premise safety ground to the chassis grounding sc
Résumé du contenu de la page N° 20
Chapter 2 Installation and Configuration Power Switch LED Indicators The chassis has two LEDs next to the power switch. The system power LED indicates the power status for the chassis. The SCXI power LED, when lit, indicates that power is available to the SCXI subsystem. The system power LED indicates one of three different conditions. 1. If the system power LED is steady green (not flashing), the chassis is powered on and operating normally. Caution Operating the PXI system outside of the s