Résumé du contenu de la page N° 1
ZT8101 Switch
User’s Manual
December 2001
Résumé du contenu de la page N° 2
® Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose,
Résumé du contenu de la page N° 3
Contents Contents 1 Introduction....................................................................................................................................9 Highlights ..............................................................................................................................9 Ethernet Features .................................................................................................................9 Layer 2 Switching Functions ..................................
Résumé du contenu de la page N° 4
Contents Priority.................................................................................................................................26 Filtering...............................................................................................................................26 MAC Address Filtering...........................................................................27 IP Address Filtering................................................................................27 Port Mirro
Résumé du contenu de la page N° 5
Contents Switch Information .................................................................................................49 Basic Switch Setup ................................................................................................49 Network Management Setup .................................................................................51 To configure SNMP................................................................................51 To configure trap recipients ................
Résumé du contenu de la page N° 6
Contents To configure a port for mirroring ............................................................71 VLAN Configuration...............................................................................................71 To configure GVRP globally...................................................................71 To create or modify a port-based VLAN ................................................72 To create or modify an 802.1Q VLAN....................................................72 To c
Résumé du contenu de la page N° 7
Contents To update firmware ................................................................................92 To download a configuration file ............................................................93 To upload a configuration file.................................................................93 To upload a history log file .....................................................................93 To test connectivity with ping ...............................................................
Résumé du contenu de la page N° 8
Contents Link Aggregation..................................................................................................113 To configure a link aggregation group .................................................114 Layer 3 - IP Networking ....................................................................................................114 Setting Up IP Interfaces.......................................................................................114 To set up IP interfaces on the switch..
Résumé du contenu de la page N° 9
Introduction 1 The ZT8101 board is a high performance managed switch that supports both Layer 2 and Layer 3 features. For fast connection speeds and flexibility, it has 24 10/100 Mbps Fast Ethernet ports and 2 gigabit Ethernet ports in a 6U CompactPCI* form factor board. The in-chassis switch minimizes external wiring and needs no extra rack height, thus improving density and reliability. You can manage the switch from a terminal, with Telnet, from a Web browser, or through IPMI via the Cha
Résumé du contenu de la page N° 10
Introduction Per device packet buffer: 512 KB 8.8 Gbps switching fabric capacity Store and forward switching forwarding mode 8 KB Layer 2 MAC address Broadcast and multicast storm control Port mirroring Port aggregation IEEE 802.1D Spanning Tree Protocol IEEE 802.1Q tagged VLANs GVRP (GARP VLAN Registration Protocol) for automatic VLAN configuration IEEE 802.1p priority support with 4 priority queues IGMP Snooping with broadcast control Layer 3 Switching Functions Wire
Résumé du contenu de la page N° 11
Introduction Management Functions RS-232 port for out-of-band management and system diagnostics Telnet remote control console Web-based management console SNMP v1 Agent Supported MIBs — MIB-II — Bridge MIB — RMON MIB (Statistics, History, Alarm, Event) — RIP MIB — CIDR MIB — 802.1p MIB TFTP IP filtering on management interface DHCP client Password enabled Warranty 2 years Product Information and Sales Support Tel. (805) 541-0488 www.Intel.com ZiatechInfo@Intel.com ZT8101 User’
Résumé du contenu de la page N° 12
Introduction 12 ZT8101 User’s Manual
Résumé du contenu de la page N° 13
Installation and Initial Setup 2 This chapter provides installation and initial setup information for the switch. Installing the Board These instructions explain the mechanical aspects of installing a ZT8101board. The board should be installed in a PICMG* 2.16 compliant fabric slot. 1. System power does not need to be off to insert a ZT8101 board. 2. Prepare the board by opening the injector/ejector mechanisms. Injector/Ejector Operations Open Closed 3. Carefully align the edges of the board w
Résumé du contenu de la page N° 14
Installation and Initial Setup Power on After the power switch is turned on, the LED indicators should respond as follows: All LED indicators will momentarily blink, which represents a reset of the system. The board status LED indicator will blink while the switch loads onboard software and performs a self-test. After approximately 20 seconds, the LED will light again to indicate the switch is in a ready state. The hot-swap LED indicator will be off. The port LED indicators will be of
Résumé du contenu de la page N° 15
Installation and Initial Setup Identifying External Components This chapter describes the front panel and the LED indicators of the ZT-8101switch. The front panel consists of LED indicators, a management serial port, a toggle button, two 10/100 Ethernet ports, and two 100/1000 Ethernet ports. Management Serial Port 12 34 56 78 910 Ethernet Channel LEDs 11 12 13 14 (Activity/Speed) 15 16 17 18 19 20 21 22/f 23 24 Front Panel Ethernet Port LEDs (Activity/Speed) 25 26 LINK Toggle Activity/Speed L
Résumé du contenu de la page N° 16
Installation and Initial Setup Status LEDs The two LEDs at the bottom of the font panel are status LEDs. The top LED indicates the overall status of the board and the bottom LED indicates the hot swap status of the board. Health Status LED Status Meaning Off Not powered. Green Powered and functioning normally. Attention needed due to one of the following conditions: Over temperature Amber Backend supplies exceeding voltage limits IPMB time outs Hot Swap LED Status Meaning Off Switch is ac
Résumé du contenu de la page N° 17
Installation and Initial Setup Link / Speed LED Mode Port Type Status Meaning 10/100 Off 10 Mb/s Solid Green 100 Mb/s 100/1000 Solid Green 100 Mb/s Solid Amber 1000 Mb/s Getting Started with Management The switch contains the following components: A CPU Memory for data storage Flash memory for configuration data, operational programs, and SNMP agent firmware. These components allow you to manage and monitor the switch from either the board’s serial port or the network itself. You can con
Résumé du contenu de la page N° 18
Installation and Initial Setup The serial port on the front panel uses Cisco* cable kit (Order Number: ACS-DSBUASYN). This kit includes a DB25 terminal adapter, a DB-9 terminal adapter, and RJ-45 rollover cable. A terminal (such as a VT-100) or a computer running a terminal emulation program (such as HyperTerminal, which is automatically installed with Windows*) is connected to this cable. The serial port is set at the factory for the following configuration: Baud rate: 9600 Data width: 8
Résumé du contenu de la page N° 19
Installation and Initial Setup 2. To configure the IP address, use the Arrow keys or the Tab key to modify the settings in the New Switch IP Settings column. Parameter Default Description Specifies the method for assigning the switch an IP address. Get IP From Manual Use the spacebar to toggle to Manual, DHCP, or BOOTP. IP Address 10.90.90.90 Specifies the IP address assigned to the switch. Specifies the subnet mask assigned to the switch and to the Subnet Mask 255.0.0.0 other devices on this
Résumé du contenu de la page N° 20
Installation and Initial Setup 4. When the power on self test message appears, press the # key and wait for the following message: Please change your baud rate to 115200 for the Zmodem upgrade, or press CTRL+C to go to the BOOT Menu. If you press CTRL+C, you can configure the baud rate to a different value. 5. Change HyperTerminal’s baud rate to match the target’s setting. 6. Use the Send File function of HyperTerminal to upgrade the firmware. When the download is completed, Zmodem will disp