Résumé du contenu de la page N° 1
MSM-6226
User's Manual
24-Port L2 Plus Managed Fast Ethernet Switch
+ 2 TP/SFP Gigabit Dual Media
Release 1.0
2011, ICPDAS Manufacture Corporation. All rights reserved. All brand and product
names are trademarks or registered trademarks of their respective companies.
Publication date:March., 2011
i
Revision A1
Résumé du contenu de la page N° 2
The information in this document is subject to change without notice. Unless the explicit written permission of ICPDAS Manufacture Corporation, this document in whole or in part shall not be replicated or modified or amended or transmitted, in any from, or by any means manual, electric, electronic, electromagnetic, mechanical, optical or otherwise for any purpose. DURATION OF HARDWARE WARRANTY HARDWARE: In accordance with the provisions described under, ICPDAS Manufacture Corporation
Résumé du contenu de la page N° 3
external or electrical stress, shipment, storage, accident, abuse or misuse, (3) Product is used in an extra hazardous environment or activities, (4) any serial number on the Product has been removed or defaced, or (5) this warranty will be of no effect if the repair is via anyone other than Manufacture or the authorized agents. The maximum liability of ICPDAS Manufacture under this warranty is confined to the purchase price of the Product covered by this warranty. DISCLAIMER. EXCEPT AS
Résumé du contenu de la page N° 4
Table of Contents CAUTION ........................................................................................................................... IV ELECTRONIC EMISSION NOTICES....................................................................................... IV 1. Introduction.......................................................................................................................1 1-1. OVERVIEW OF MSM-6226 ..........................................................
Résumé du contenu de la page N° 5
3-9-1. IGMP Setting.................................................................................................... 65 3-9-2. IGMP VLAN ..................................................................................................... 66 3-9-3. Group Allow ..................................................................................................... 68 3-9-4. MVR Setting...................................................................................................... 69 3-9
Résumé du contenu de la page N° 6
Appendix B Null Modem Cable Specifications .............................................................282
Résumé du contenu de la page N° 7
Revision History Release Date Revision 1.0 2011/03/21 A1 Publication date: March., 2011 vii Revision A1
Résumé du contenu de la page N° 8
Caution Circuit devices are sensitive to static electricity, which can damage their delicate electronics. Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electrical charge. To protect your device, always: • Touch the metal chassis of your computer to ground the static electrical charge before you pick up the circuit device. • Pick up the device by holding it on the left and right edges only. • If you need using outdoor device connect to this
Résumé du contenu de la page N° 9
Résumé du contenu de la page N° 10
Warrning: • Self-demolition on Product is strictly prohibited. Damage caused by self- demolition will be charged for repairing fees. • Do not place product at outdoor or sandstorm. • Before installation, please make sure input power supply and product specifications are compatible to each other. • Before importing / exporting configuration please make sure the firmware version is always the same. • After firmware upgrade, the switch will remove the configuration automatically to latest
Résumé du contenu de la page N° 11
About this user’s manual In this user’s manual, it will not only tell you how to install and connect your network system but configure and monitor the MSM-6226 through the built-in CLI and web by RS-232 serial interface and Ethernet ports step-by-step. Many explanation in detail of hardware and software functions are shown as well as the examples of the operation for web-based interface and command-line interface (CLI). Overview of this user’s manual Chapter 1 “Introduction” desc
Résumé du contenu de la page N° 12
Résumé du contenu de la page N° 13
1. Introduction 1-1. Overview of MSM-6226 MSM-6226, a 24 Fast Ethernet + 2 Gigabit L2 Managed Switch, which implemented 24 10/100Mbps TP + 2 Gigabit dual media ports with TP/SFP(or GBIC), is a standard switch that meets all IEEE 802.3/u/x/z Gigabit, Fast Ethernet and Ethernet specifications. The switch can be managed through RS-232 serial port via directly connection, or through Ethernet port using Telnet or Web-based management unit, associated with SNMP agent. With the SNMP agent,
Résumé du contenu de la page N° 14
DHCP Snooping: This feature enables the DHCP Snooping (MSM-6226 switch) to include information about client when forwarding DHCP requests from a DHCP client to a DHCP server via Trust Port. DHCP snooping can be configured on LAN switches to harden the security on the LAN to only allow clients with specific IP/MAC addresses to have access to the network. In short, DHCP snooping ensures IP integrity on a Layer 2 switched domain. QoS: Support Quality of Service by the IEEE 802.1P standard.
Résumé du contenu de la page N° 15
• When queried, sends group membership reports to the group. • When one of its hosts joins a multicast address group to which none of its other hosts belong, sends unsolicited group membership reports to that group. • When the last of its hosts in a particular multicast group leaves the group, sends an unsolicited leave group membership report to the all-routers group (244.0.0.2). Power Saving: The Power saving using the "ActiPHY Power Management" and "PerfectReach Power Management"
Résumé du contenu de la page N° 16
1-2. Checklist Before you start installing the switch, verify that the package contains the following: ─ MSM-6226 24 Fast Ethernet + 2 Gigabit L2 Managed Switch ─ Modules (optional) ─ Mounting Accessory (for 19” Rack Shelf) ─ This User's Manual in CD-ROM ─ AC Power Cord ─ RS-232 Cable Please notify your sales representative immediately if any of the aforementioned items is missing or damaged. 1-3. Features The MSM-6226, a standalone off-the-shelf switch, provides the comprehen
Résumé du contenu de la page N° 17
• Supports 802.1Q VLAN with 4K entries. • Supports user management and limits three users to login • Supports DHCP Broadcasting Suppression to avoid network suspended or crashed • Supports to send the trap event while monitored events happened • Supports Link Layer Discovery Protocol (LLDP, IEEE802.1AB) • Supports default configuration which can be restored to overwrite the current configuration which is working on via web browser and CLI • Supports on-line plug/unplug SFP/GBIC modu
Résumé du contenu de la page N° 18
1-4. View of MSM-6226 Fig. 1-1 Full View of MSM-6226D with SFP Module 1-4-1. User Interfaces on the Front Panel (Button, LEDs and Plugs) There are 24 TP Fast Ethernet ports and 2 slots for optional removable modules on the front panel of the switch. LED display area, locating on the front panel, contains a CPURUN, Power LED and 26 ports working status of the switch. LEDSET Button Fast Ethernet LEDSET button LED SET Mode: ACT/FDX/SPD is used to change the LED displa
Résumé du contenu de la page N° 19
•••• LED Indicators LED Color Function System LED CPURUN Green Lit when CPU is on and good POWER Green Lit when AC power is on and good ACT Green Lit when LEDSET set on active mode FDX Green Lit when LEDSET set on full-duplex mode SPD Green Lit when LEDSET set on speed mode 10/100Mbps Ethernet TP Port 1 to 24 LED Lit when connection with remote device is good LNK Green Off when cable connection is not good a. LEDSET set on ACT (active) mode: Blinks when any traffic is p
Résumé du contenu de la page N° 20
2. Installation 2-1. Starting MSM-6226 Up This section will give users a quick start for: - Hardware and Cable Installation - Management Station Installation - Software booting and configuration 2-1-1. Hardware and Cable Installation At the beginning, please do first: ⇒ Wear a grounding device to avoid the damage from electrostatic discharge •••• Installing Optional SFP/GBIC Fiber Transceivers to the MSM-6226 Managed Switch Note: If you have no modules, p