Résumé du contenu de la page N° 1
WSK300
Multifunction Wall Control
Installation & Operating Instructions
Note: The electrical junction box provided with the fi replace
WARNING
must be wired with 110 VAC before installing this kit. See
owners manual for details.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
All wiring should be done by a qualifi ed electrician and
shall be in compliance with local codes and with the
• Installation and use of any da
Résumé du contenu de la page N° 2
CAUTION Risk of damage to control. Ensure wires are placed into correct color coded terminals without touching other wires. • Incorrect placement or crossed wires may damage wall control. 6. Place front cover plate onto wall control. 7. Place bottom of wall control faceplate into grooves. Snap upper faceplate into place. Installing the Hi/Lo Solenoid 1. Install the solenoid (see Figure 1). 2. Remove screw and knob from variable regulator and KNOB discard. Unscrew nut from regulator and dis
Résumé du contenu de la page N° 3
BATTERY INTERMITENT PILOT PACK IPI MODULE GROUND CLIP NOT USED RED ORG BLK DEXEN IPI VALVE WALL SWITCH BACK VIEW BRN NOT SEE DETAIL B-B BRN CONNECTED ORG FOR B-VENT GRN APPLIANCES GRN GROUND BLK JUMPER HIGH LIMIT SWITCH GRN GRN YEL/WHT BLK BLU RED BLK JUMPER DETAIL B-B FOR B-VENT APPLIANCES CONTROL MODULE J-BOX (110V) CORD ASSEMBLY 2 SOLENOID NOTE: WIRE TYPE 80°C FAN Note: Appliance will not operate un- less properly grounded. Figure 2. Intellifi re Pilot Ignition (IPI) Wiring Diagram
Résumé du contenu de la page N° 4
Installing the Control Box 4. Disconnect the multiwire connector from existing green control box. Connect the end just disconnected to the matching terminal on the new black control. CAUTION 5. Connect the new lead wire set to black and green con- trol boxes matching connectors. • Do not install the control box when fi replace is hot. • Do not plug control box in until all connections are complete. 6. Attach the provided ground clip (see Figure 2) to the nearest available sheetmetal edge.
Résumé du contenu de la page N° 5
Wall Control - WSK300 Control Specifi cations Wall Control MODE display section LOSS OF SIGNAL indicator Temperature/Heat output display section PILOT display section TIMER display section AUXILIARY function level indicator Button & Display Key Use MODE button to toggle through three mode functions “THERMOSTAT”, “ON”, and “OFF”. The THERMOSTAT and ON functions will be highlighted in yellow and OFF in red when selected. - THERMOSTAT function controls the fi replace based on a
Résumé du contenu de la page N° 6
Wall Control - WSK300 Control Specifi cations Wall Control Function - CONTINUOUS DISPLAY SCREEN • At a continuous display mode, LCD will only display the room temperature. 6
Résumé du contenu de la page N° 7
Wall Control - WSK300 Control Specifi cations Wall Control MODE set to OFF Press both arrow buttons for three seconds to change temperature scale between ºF and ºC. Function - TEMPERATURE SCALE INDICATOR • Press button until • Press both arrows OFF setting is highlighted. for three seconds to again activate the temperature scale • Press both arrows change. for three seconds to activate the temperature scale change. • Fahrenheit icon will appear with
Résumé du contenu de la page N° 8
Wall Control - WSK300 Control Specifi cations Wall Control MODE set to ON Press up or down arrows to turn fl ame HI or LO Function - ON mode Adjusting Flame Size • Pressing the UP or DOWN • Pressing UP or DOWN again arrow while the within 5 seconds will adjust continuous display screen fl ame size: = HI Flame is shown will display the = LO Flame current fl ame size. Note: Whenever the fi replace is turned on, the fl ame size will always be on
Résumé du contenu de la page N° 9
Wall Control - WSK300 Control Specifi cations Wall Control MODE set to OFF PILOT icons will display Press PILOT button Function - PILOT settings • Press button until • Press button to • Press button, again, • Once the desired PILOT OFF setting is highlighted. set pilot to “ON” for cold to set pilot to “OFF”. This function is set, continuous climate setting. will turn off cold climate display mode will be • Normal di
Résumé du contenu de la page N° 10
Wall Control - WSK300 Control Specifi cations Wall Control The Child Lockout Feature allows the user to lock any button press from changing the state of the fi replace or its features. Function - CHILD LOCKOUT feature Activating Child Lockout Feature De-activating Child Lockout Feature • Press and hold the button • Once the button is pressed • To cancel the Child Lockout Feature, for 3 seconds while the Continuous for 3 seconds, the control will be
Résumé du contenu de la page N° 11
Wall Control - WSK300 Control Specifi cations Wall Control MODE set to THERMOSTAT or ON Press UP or DOWN arrow but- tons to determine desired setting Press TIMER button Function - TIMER settings • Press button until • Press UP arrow to • Press DOWN arrow to • Once the desired TIMER ON or THERMOSTAT increase TIMER setting, decrease TIMER setting, in is set, continuous display settings are highlighted. in 15 minute increments, 15 minute de
Résumé du contenu de la page N° 12
Wall Control - WSK300 Control Specifi cations Wall Control THERMOSTAT mode will automatically adjust fi replace Flame Size and Fan Speed based on the desired room temperature. If AUX 1 (Fan) is pressed Press MODE to set AUT will display on the screen. THERMOSTAT (When the control is fi rst powered, the THERMOSTAT mode will gather room temperature information for 4 minutes before it will begin to operate SET ROOM TEMP -after 4 minutes of having power will display THERMOSTAT mode w
Résumé du contenu de la page N° 13
Wall Control - WSK300 Control Specifi cations Auxiliary Features Wall Control The button will operate the following 3 auxiliary features: A1 = FAN (always room heating) A2 = SWITCHES 110VAC, HI/MED/LOW A3 = SWITCHES 110VAC, ON/OFF First press the button multiple times to scroll through to the desired Auxiliary feature (A1, A2, or A3). If desired Auxiliary selected is A1 or A2 Press UP or DOWN use the UP or DOWN arrow to step arrow buttons to through the following 4 leve
Résumé du contenu de la page N° 14
Power Out Operation: Service: In a power out condition, the wall control display screen If the symbol appears on the wall control, this indi- will not work. The only operable functions will be ON and cates a loss of communication between the wall control OFF. and the control module. Check the following: 1. Install 2 D cell batteries into battery holder located 1. Unplug the control module from the junction box, and in the valve cavity. This may require removal of the remove any bat
Résumé du contenu de la page N° 15
TROUBLESHOOTING The operating characteristics of your fi replace may vary during a power failure or power outage. the options listed below will help determine the current state of your system. Condition (at time of power failure) Result Wall switch is in THERMOSTAT mode The fi replace will shut down and the display lights in the wall switch will be off. When the with the main fl ame on and has no battery power is restored to the system it will return to THERMOSTAT mode. The display lights bac
Résumé du contenu de la page N° 16
TROUBLESHOOTING (continued) The operating characteristics of your fi replace may vary during a power failure or power outage. the options listed below will help determine the current state of your system. Condition (at time of power failure) Result The wall switch is in ON mode with the main fl ame on and it has The fi replace will stay on and the main burner will turn to HIGH, battery backup the FOL* (Flame on a Log) will also have fl ame. The display lights in the wall switch will be off and