Résumé du contenu de la page N° 1
Corporate Headquarters
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539-7437
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email support@garrettcom.com
Magnum 3000
Stackable Hubs
Installation and User Guide
www .. GarrettCom com www .. GarrettCom com
Résumé du contenu de la page N° 2
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) Magnum™ 3000 Stackable Hubs Installation and User Guide Part #: 84-00060 (Rev. 04/02 ) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. Important:
Résumé du contenu de la page N° 3
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Federal Communications Commission Radio Frequency Interference Statement This equipm
Résumé du contenu de la page N° 4
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) PREFACE This user guide is divided into six main sections: SECTION 1 covers the product specifications for Magnum 3000 Stackable Hubs family, and also provides ordering information. SECTION 2 covers the Magnum 3024 and 3012 Stackable Hubs. SECTION 3 describes Magnum Repeater Port Modules (RPMs) and Bridge Port Modules (BPMs) including features, installation and operation. SECTIO
Résumé du contenu de la page N° 5
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) Table of Contents Page 1.0 SPECIFICATIONS - MAGNUM 3024, MAGNUM 3012................ 1 1.1 Specifications - Repeater Port Modules (RPMs); Bonus Ports........... 3 1.2 Specifications - Bridge Port Modules (BPMs); Bonus Ports............. 3 1.3 Ordering Information........................................................................... 4 2.0 INTRO - MAGNUM 3012 AND 302
Résumé du contenu de la page N° 6
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 5.0 INTRO SIMPLE NTWRK MGMT PROTOCOL (SNMP) AGENTS32 5.1 SNMP Agents Description................................................................. 32 5.1.1 Embedded SNMP Agent, Model 3000-MB.............................. 32 5.1.2 Separate Agent Box, Model 3000-AGT ................................... 33 5.1.3 Standard Repeater MIB and Extensions .................................... 33 5.2 I
Résumé du contenu de la page N° 7
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary
Résumé du contenu de la page N° 8
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 1.0 Specifications - Magnum 3024, Magnum 3012 Performance Data Rate: 10 Mbps RPM Partitioning: Enforced after 32 consecutive collisions RPM Reconnect: Occurs after 512 bits error-free reception BPM Auto-Learning Address List: 256 nodes capacity BPM Filtering and Forwarding Rate: 14,880 pps max. Maximum Ethernet Segment Lengths DTE (AUI Drop Cable) - 50 m (164
Résumé du contenu de la page N° 9
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) DC Power Supply (Options) -48VDC Power Input Voltage : 36 to 72 VDC 24VDC Power Input Voltage : 20 to 36VDC 125VDC Power Input Voltage : 120 to 300VDC Std. Terminal Block : “ -, GND, + ” Power Consumption: same as for AC models, see above For Dual Source and Redundant DC for –48VDC, 24VDC Power & 125VDC supply options (Optional), see Appendices. Packaging Enclosures:
Résumé du contenu de la page N° 10
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 1.1 Specifications - Repeater Port Modules (RPMs); Bonus Ports RPM Type : BNC AUI DTE Fiber-mm Fiber-sgl.m TP* Front Access yes yes yes yes yes yes Connector Type BNC-f DB-15 f DB-15 m Fiber-ST Fiber-ST RJ-45 Partition (PART)LED yes yes yes yes yes yes Receive (RX) LED yes yes yes yes yes yes LINK LED n.a. n.a. n.a. yes yes yes Switch on Face Plate yes** n.a. n.a. n.a.
Résumé du contenu de la page N° 11
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 1.3 Ordering Information Magnum 3000 Stackable Hubs and Concentrators Magnum 3024 Base Chassis with 24 RJ-45 ports, shielded connectors Magnum 3012 Base Chassis with 12 RJ-45 ports, shielded connectors ETSI and NEBS-certified models, -48VDC powered Magnum 3012-NEBS NEBS Level 3 tested and certified with -48VDC power supply Base Chassis with 12 RJ-45 ports Magnum 3024-NEBS NEBS Level 3
Résumé du contenu de la page N° 12
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 2.0 Introduction - Magnum 3012 and 3024 Stackable Hubs This section describes the features and capabilities of the Magnum 3012 and 3024 Stackable Hubs, including bonus ports, applications, installation, and operation. 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage which you believe
Résumé du contenu de la page N° 13
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 2.2 Product Description - Magnum 3000 Stackable Hubs Magnum 3000 Stackable Hubs are suitable for small- to medium-size enterprises needing an Ethernet local area network, either managed or unmanaged. They will operate, individually or combined in a stack, as self-sufficient devices to provide 10BASE-T Ethernet connectivity for all local users and devices. Small independent networks built usi
Résumé du contenu de la page N° 14
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 2.3 Magnum 3024 Hub - 24 RJ-45 Ports, One PM bonus port slot The Magnum 3024 Hub provides 24 RJ-45 ports on the front of the unit plus a Bonus Port slot on the rear which may be configured with any Magnum Port Module (PM). User-segment wiring connections are made on the front of the unit, and status- indicator LEDs are located immediately above each of the 24 ports. Steady On LINK LED =
Résumé du contenu de la page N° 15
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) The IRB ribbon cables supplied with each Magnum 3000 base unit are slightly longer than the base unit height. Thus, an IRB cable segment has a small arc shape when it is properly installed. It is possible to have some long IRB ribbon cable segments, up to a few meters in length, for service loops and such. The operation of the stack will not be impaired by longer IRB ribbon cables. Stacks w
Résumé du contenu de la page N° 16
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) into two logical repeaters with separate IRB cables collision domains, while still passing SNMP Magnum 3024 hub management data through the SRC so that the Magnum 3024 hub one agent can manage both repeaters. Then, a local repeater Magnum 3024 hub bridge can be installed between the two Magnum 3024 hub repeaters using a port from each (for example, Magnum 3000-AGT rear front using a bonus port
Résumé du contenu de la page N° 17
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) NOTE: To differentiate the SRC cable from the IRB cable, GCI uses colored ribbon cable for the SRC. The standard IRB cables are gray in color. 2.3.3 Group # Address Switch Settings, for Managed Units and Stacks The eight-position DIP switch on the rear panel is used to give each unit in a Magnum 3000 managed stack a unique Group # or "stack address". This Group # follows the SNMP defin
Résumé du contenu de la page N° 18
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) The Group # switch settings must not be the same for any two Magnum 3000 units operating in one managed stack. Factory default switch settings cannot be relied upon, and the user must check and/or change the Group # address switch settings for each managed Magnum 3000 unit installed. If a network management software package is in use, the Group # addresses set for each Magnum 3000 physical
Résumé du contenu de la page N° 19
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) There is no upgrade from a Model 3012 to a Model 3024 since it would not provide an economical method of adding ports. Note that the high degree of stacking of Magnum 3000s - up to 20 units! - provides essentially unlimited expansion of the number of users by adding more units to the stack. 2.5 Rear Bonus Slot, Port Modules (PMs) The Magnum 3012s and 3024s are each equipped with a bonus
Résumé du contenu de la page N° 20
Magnum 3000 Stackable Hubs Installation and User Guide (07/06) The family of standard connector types for BPMs is shown in Figure 2.5b. Figure 2.5b: Magnum BPM Modules for Bonus Ports (left to right above) BPM-BNC, BPM-AUI, BPM-FST, BPM-TP (Note: When an RPM-AUI type is configured as a bonus port, it is typically implemented at the factory as an AUI connector with a ribbon cable to header pins on the main board. The functionality is the same as the