Résumé du contenu de la page N° 18
3.3.2 IP Settings There are three tunable parameters to be set by the system administrator: • Enter site-specific IP address, Gateway address and Network mask • Click Apply to change the IP settings • Save Configuration to NVRAM and reset the system to implement the changes 3.3.3 NVRAM Admin After making any changes to the screens within the Web Interface, users must save the changed settings to Non-Volatile Random Access Memory (NVRAM). This is do
Résumé du contenu de la page N° 19
3.3.4 Firmware Update On the Firmware Update screen, the system can be configured to download and boot from a new image off the network (Please refer to Chapter 5 when updating software). Choose from the following options: Net option: This option allows the user to try out a new image before upgrading. It requires a TFTP server and a server IP address to retrieve the specified image from the given IP address. The new image will not overwrite the one i
Résumé du contenu de la page N° 20
3.4 Port Manager This page will allow access to the port parameters. The configurable parameters are available as follows: • Port Name • Port Enable • Auto Negotiation • Operating Parameters • Flow Control • HOL Blocking 3.5 Address Manager The Address Manager allows you to add or remove static address entries as well as change the dynamic address aging times. 3.5.1 Static Addresses Any system whose MAC address and the port number are lis
Résumé du contenu de la page N° 1
™
IntraCore 65120 Series
Gigabit Ethernet Switches
User’s Manual
Résumé du contenu de la page N° 2
Quick Start Guide Follow these steps to install the IntraCore 65120: 1. Open the box and check the contents. See Chapter 2.1 Package Contents for a complete list of the items included with your IntraCore 65120. 2. Install the IntraCore 65120 switch in an equipment or wall rack, or prepare it for desktop placement. 3. Connect the power cord to the switch. 4. Connect network devices to the IntraCore 65120. Refer to Chapters 3 and 4 to configure the IntraCore 65120 for management capab
Résumé du contenu de la page N° 3
™ IntraCore 65120 Series Gigabit Ethernet Switches User’s Manual Asanté Technologies, Inc. 821 Fox Lane San Jose, CA 95131 USA SALES 800-662-9686 Home/Office Solutions 800-303-9121 Enterprise Solutions 408-435-8388 TECHNICAL SUPPORT 801-566-8991 Worldwide 801-303-3787 FAX www.asante.com support@asante.com Copyright © 2001 Asanté Technologies, Inc. All rights reserved. No part of this document, or any associated
Résumé du contenu de la page N° 4
Table of Contents Quick Start Guide 2 Chapter 1 Introduction 6 1.1 Front Panel Descriptions 6 1.2 LED Definitions 7 1.3 Management 8 Chapter 2 Installation and Setup 10 2.1 Package Contents 10 2.2 Installation Overview 10 2.3 Setup 12 2.4 Password Protection 13 2.5 IP Assignment 14 2.6 SNMP Host Access 15 Chapter 3 Web-Based Management 16 3.1 Web Pages 16 3.2 Introduction 17 3.3 System Manager 17 3.4 Port Manager 20 3.5 Address Manager 20 3.6 Spanning Tree 21 3.7 VLAN Setup
Résumé du contenu de la page N° 5
Appendix D: FCC Compliance and Safety Statements 46 Appendix E: Online Warranty Registration 47 5
Résumé du contenu de la page N° 6
Chapter 1 Introduction Thank you for purchasing the Asanté IntraCore 65120 Series Gigabit Ethernet switch. In addition to the traditional console and telnet interface, this switch can also be configured and managed through a user- friendly web browser interface. With an on-board HTTP server, users can access the box with the use of popular browsers such as Netscape Navigator and Microsoft I.E (Netscape Navigator 4.0 and IE 4.01 or higher required). The IntraCore 65120 also supports firmwar
Résumé du contenu de la page N° 7
1.2 LED Definitions The following Table describes the LEDs, which allows monitoring of the status of your switch: Port LED Color ON OFF N/A Power/System Green Power is up Power is off or system is initializing Amber Booting Red Failure 10/100/1000 1G Link Green A valid 1000 Mbps link has No 1000 Mbps link has been been established established 10/100/1000 10/100 Link Green A valid 10/100 link has been No 10/100 Mbps link has been established established 10/100/1000 Activity Bl
Résumé du contenu de la page N° 8
1.3 Management There are three different methods by which a user can manage the switch: web, console/telnet, or SNMP. 1.3.1 Web-Based Interface Users can configure the switch, monitor the LED panel, and display statistics graphically with Netscape Navigator browser version 4.0 or higher and Microsoft IE version 4.01 or higher. With Internet access, users can link directly to the local switch’s home page. Detailed description is found in Chapter 3 Web-Based Management.
Résumé du contenu de la page N° 9
1.3.4 Management Information Bases (MIBs) The system supports the following MIBs: 1. MIB II (RFC 1213) 2. Ethernet Interface MIB (RFC 1643) 3. Bridge MIB (RFC 1493) 4. 4 groups of RMON (RFC 1457) • The Ethernet Statistics Group • The Ethernet History Group • The Alarm Group • The Event Group 5. Enterprise MIB • CommGroup: Allows users to configure the community database • HostGroup: Allows users to configure the hosts • MiscGroup: Allows users to configure miscellaneous items •
Résumé du contenu de la page N° 10
Chapter 2 Installation and Setup This chapter provides the following information: • Package Contents • Installation • Setup • Password Protection • IP Assignment • SNMP Host Access 2.1 Package Contents The IntraCore 65120 package contains the following: • IntraCore 65120 Series Gigabit Ethernet switch • Getting Started Guide (printed) • Power Cord • Self-adhesive rubber feet for desktop placement • Rack mount kit for rack installation • IntraCore 65120 CD-ROM with user’s
Résumé du contenu de la page N° 11
• Examine your work area for potential hazards (I.e. wet floors, ungrounded cables, etc. 2.2.2 Recommended Installation Tools You will need the following tools and equipment (not included) to install the IntraCore 65120 switch: • Number 1, number 2 and 3/16-inch flat-blade screwdrivers • Antistatic mat or foam 2.2.3 Power Requirements The electrical outlet should be located near the IntraCore 65120 and be easily accessible. It must also be properly grounded. Make sure the pow
Résumé du contenu de la page N° 12
2.2.7 Equipment Rack Guidelines • Size: 17.25 x 10.0 x 1.7 inches 423 x 245 x 43 mm • Ventilation: Ensure that the rack is installed in a room where the temperature remains below 40° C (104° F). Be sure that there are no obstructions, such as other equipment or cables, blocking airflow to or from the IntraCore 65120 vents. • Clearance: In addition to providing clearance for ventilation, ensure that there is adequate clearance for servicing the IntraCore 65120 from the front.
Résumé du contenu de la page N° 13
2.4 Password Protection The Password Protection feature is disabled by default, allowing immediate access to ANYONE on the network. To protect your switch from unauthorized changes to the configuration, you must enable the protection feature. It can only be enabled through the console interface. To set a password via telnet, follow these steps: Note: Use the arrow keys to move within a menu. Press Enter to proceed, and press the Esc. Key to return to the previous screen. Use the spac
Résumé du contenu de la page N° 14
4. Now enter your password, pressing Enter when done. 5. Enter the password again to confirm, pressing Enter when done. 6. Press Ctrl+W to save. 2.5 IP Assignment To assign an IP address (other than the default IP address): 1. From the Main Menu, select a. System Manager. 2. Select b. IP address. 3. In the first field enter the proper IP address for this system (consult your network administrator). 4. En
Résumé du contenu de la page N° 15
6. Press Ctrl-W when done to save these changes. 7. After making IP changes, the system needs to be reset. Press the Esc key to return to the System Manager Menu. 8. Go to System Manager/Reset. Use the arrow keys to select Yes to proceed with Reset. 2.6 SNMP Host Access When the reset is complete the box should be seen on the network. If not, check the IP information again with your network administrator to ensure that all the data is correc
Résumé du contenu de la page N° 16
Chapter 3 Web-Based Management Web-Based Management allows switch configuration changes to be made using an Internet Web browser. This interface also allows for system monitoring of the Switch. Buttons featured are: • Reload: Pulls that screen’s data from current values on the system • Apply: Submits change request to system and refreshes screen data Please refer to Chapter 6 Switching Concepts to review any features that are not familiar to you. 3.1 Web Pages Connect to th
Résumé du contenu de la page N° 17
3.2 Introduction This page briefly describes the web-based management features, device management and Interface operation. It contains a product overview and product features. 3.3 System Manager The system manager contains all system operations and general information. It is organized with several sub-folders: • General Info: General system information and administration • IP Settings: IP parameters • NVRAM Admin: Save conf