INSTRUCTION MANUAL
Simrad HS50
Heading Sensor
Résumé du contenu de la page N° 2
Note! Simrad AS makes every effort to ensure that the information contained within this document is correct. However, our equipment is continuously being improved and updated, so we cannot assume liability for any errors which may occur. Warning! The equipment to which this manual applies must only be used for the purpose for which it was designed. Improper use or maintenance may cause damage to the equipment or injury to personnel. The user must be familiar with the contents of the appro
Résumé du contenu de la page N° 3
INSTRUCTION MANUAL Instruction Manual HS50 Heading Sensor This manual is intended as a reference guide for installing, operating and maintaining Simrad HS50 Heading Sensor. 20221081 / F i
Résumé du contenu de la page N° 4
Simrad HS50 Heading Sensor Document revisions Rev Date Written by Checked by Approved by FOS/ A 12.06.02 B 26.09.02 C 06.11.02 FOS/ D 02.04.03 FOS/ E 06.11.03 F 07.01.04 Document history Rev. A Original issue. Rev. B The manual updated and rewritten. Rev. C Cable pair numbers for Sensor unit corrected (page 13). Optional documentation for additional languages added. Rev. D Updated to correspond with PU sw version 2.02.03 and DU sw version 1.02. Rev.
Résumé du contenu de la page N° 5
INSTRUCTION MANUAL Contents 1. INTRODUCTION ................................................................1 1.1 HS50 System components............................................. 1 1.2 About this manual........................................................ 3 1.3 Definitions, abbreviations and acronyms.......................... 3 Definitions .......................................................................3 Abbreviations and acronyms..............................................
Résumé du contenu de la page N° 6
Simrad HS50 Heading Sensor Cable wiring................................................................... 13 Waterproofing the connectors........................................... 14 3.5 Display unit................................................................14 Location of the unit ......................................................... 14 Panel mounting .............................................................. 15 Bracket mounting (option) .....................................
Résumé du contenu de la page N° 7
INSTRUCTION MANUAL Processing unit............................................................... 44 Display unit ................................................................... 44 Software upgrades.......................................................... 44 5.3 Repairs and modifications.............................................45 Replacing damaged cables ............................................... 45 Replacing damaged units ................................................. 45
Résumé du contenu de la page N° 8
Simrad HS50 Heading Sensor THIS PAGE INTENTIALLY LEFT BLANK vi 20221081 / F
Résumé du contenu de la page N° 9
INTRODUCTION 1. INTRODUCTION 1.1 HS50 System components Simrad HS50 is a GPS compass that provides true heading output with position, velocity and rate of turn information in addition. This product replaces several vessel instruments with one compact navigation package: gyrocompass, GPS system, speed log and Rate Of Turn (ROT) indicator. The HS50 comprises the following units: SENSOR UNIT 1m DISPLAY UNIT 30m 15m PROCESSING UNIT POWER INPUT The Sensor unit contains two GPS sens
Résumé du contenu de la page N° 10
Simrad HS50 Heading Sensor High-precision heading is derived from the fixed-distance dual GPS antenna arrangement in the Sensor unit, using carrier phase data to generate heading information independent of latitude and vessel dynamics. GPS position and speed are calculated from both antennas, which give redundant position and velocity sources in this product. DGPS signals may be input to the HS50 to improve position and velocity accuracy, but has no impact on the heading accuracy. Refer
Résumé du contenu de la page N° 11
INTRODUCTION 1.2 About this manual This manual is intended as a reference guide for operating, installing and maintaining the HS50 Heading Sensor. Please take time to read this manual to get thorough understanding of the operation and system components. In this manual the following notations are used: Caution! Used to make the user aware of procedures and operational practice which, if not followed, may result in degraded performance or damage to the equipment. Note! Used to draw the u
Résumé du contenu de la page N° 12
Simrad HS50 Heading Sensor Abbreviations and acronyms CEP Circular Error Probability COG Course Over Ground DGPS Differential GPS DU HS50 Display Unit EPE Estimated Position Error GPS Global Positioning System GSA A standard NMEA message including GPS satellite ID numbers, PDOP, HDOP and VDOP HDOP Horizontal Dilution Of Precision HGT GPS Antenna Height above the WGS-84 ellipsoid International Electrotechnical Commission IEC International Maritime Organization IMO Input/Output I/
Résumé du contenu de la page N° 13
TECHNICAL SPECIFICATIONS 2. TECHNICAL SPECIFICATIONS 2.1 Health, environment and safety Operation or troubleshooting of HS50 equipment will not imply any risk for high voltages, explosions or exposure to gas. The HS50 is type-approved according to IEC 950/EN60950 standards regarding product safety (low voltage), and IEC 945/EN60945 standards on electromagnetic compatibility (immunity/radiation) and vibration. 2.2 Restrictions in guarantee The liability of the manufacturer is limited to
Résumé du contenu de la page N° 14
Simrad HS50 Heading Sensor 2.4 Performance data Heading accuracy, static:...............................................0.3° RMS Heading accuracy, dynamic:..........................................0.5° RMS Heading resolution:............................................................... 0.01° Heading operational measurement range: .Roll/pitch within ±30° Rate of turn accuracy:................................................. 0.5º/s + 5% Position accuracy:.................................
Résumé du contenu de la page N° 15
TECHNICAL SPECIFICATIONS Processing unit Width: ...............................................................287 mm (11.3 in.) Height: ...................................................................203 mm (8 in.) Depth: ...................................................................60 mm (2.4 in.) Weight: ................................................................ 1.3 kg (2.9 lbs.) Color: ................................................................................... Bla
Résumé du contenu de la page N° 16
Simrad HS50 Heading Sensor Processing unit Enclosure material: .......................................Anodized aluminum Enclosure protection:............................................................. IP44 Operating temperature range: ................0 to +55ºC (32 to 131°F) Storage temperature range:................. -20 to +60ºC (-4 to 140°F) Safe distance to compass: ........................................ 0.2 m (0.7 ft) 2.8 Cable Processing unit to sensor unit cable 2 Type: ....
Résumé du contenu de la page N° 17
INSTALLATION 3. INSTALLATION 3.1 General The following parts are supplied with a standard HS50 system: − Sensor unit with 1 meter cable w/connector and 4 fastening bolts − Display unit with 15 meters cable to the Processing unit and flush mounting kit − Processing unit including 4 fastening screws − 30 meters cable to be used between Sensor unit and Processing unit − Documentation Caution! The Sensor unit has to be mounted in a way that avoids blocking of the GPS signal. The Pro
Résumé du contenu de la page N° 18
Simrad HS50 Heading Sensor 3.4 Sensor unit Location of the unit The Sensor unit is the most important part of the HS50 system, and great care should be taken when deciding the mounting location. The space above the Sensor unit has to be free of obstructions of any kind. A GPS compass is more sensitive for blocking and reflections (multipath) of GPS signals than GPS sensors that are only used for calculating position. This since HS50 also utilizes carrier phase measurements for heading
Résumé du contenu de la page N° 19
INSTALLATION Mechanical installation The Sensor unit may be mounted in the mast or directly on the deck. The dimensional drawing for the Sensor unit on page 50 shows dimensions and internal distance for the mounting holes and the cable outlet. If necessary, a user-made holder may be used as shown on the figure when installing the unit. Holder Bracket A mounting bracket (part no. 20213039) or a mounting pedestal (part no 20213021) can be delivered from Simrad by request. Dimensio
Résumé du contenu de la page N° 20
Simrad HS50 Heading Sensor Bracket mounting (option) An optional mounting bracket (part no. 20213039) can be delivered from Simrad by request. Assemble the mounting bracket to the Sensor unit with the four screws with washers as shown in the figure below. 4 11 12 10 Holder Connect the cable from the Processing unit to the cable as described in page 11. Cable ties Connector with self-bonding tape Cable duct 12 20221081 / F