Résumé du contenu de la page N° 1
Colors of Speakers
When choosing speakers, it is important to consider the strucutre
or wood quality of the building or the interior.
As much as possible, Panasonic speakers have been designed
to harmonize with a variety of interiors.
Because building interiors tend to be predominantly white,
we have used it as the standard underlying tone.
To accentuate the mood of your interior,
simply choose the most appropriate shade.
Integrated White Off White
(Munsell 10Y9/1) (Munsell 5Y8.5/1)
WS
Résumé du contenu de la page N° 2
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS Concept 1 P4 ~ P7 Booster Power Amplifier WA-BA240N (240W) Mixing Power Amplifier WA-MA120N (120W) Mixing Power Amplifier WA-MA240N (240W) System Examples 2 P8 ~ P15 Sound Message Unit WU-ZM001E TABLE Connections 3 P16 ~ P43 OF Surveillance Unit WU-ZS001E CONTENTS Remote Microphone Products WR-201E 4 P44 ~ P73 Remote Control Microphone WR-210AE Block Diagrams 5 P74 ~ P79 2 3
Résumé du contenu de la page N° 3
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONCEPT CONCEPT 1 1 CONCEPT CONCEPT The Public Address System Made it Easy. All-in-One Mixer and Amp Select Call Sign Up to four (4) Remote Microphones From the simplest to the most complex public address needs, the WA-MA120N (1) Rising 4 sounds, (2) Falling 4 sounds, (3) Two sounds, one time and WA-MA240N have what it takes. These mixing power amplifiers combine multiple inputs with assigned priorities and call Switch to on for 2-c
Résumé du contenu de la page N° 4
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONCEPT CONCEPT 1 1 BASIC SYSTEM DIAGRAM BASIC SYSTEM DIAGRAM Mixing Power Amplifier (WA-MA120N/240N) Connection Schematic diagram of Remote Microphone with Extension Unit (WU-RM205E) connected for announcements on 15 channels. The illustration in the broken line frame shows how to connect more than one Remote Microphones to Mixing Power Amplifier. Refer to this illustration for method of connecting up to 4 Remote Microphones. Master R
Résumé du contenu de la page N° 5
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS SYSTEM EXAMPLES SYSTEM EXAMPLES 2 2 DEPARTMENT STORE FACTORY Department Store Outline Factory Outline KEY POINT KEY POINT • Remote-controlled Microphone Connection • Cascade Connection Allows remote microphones to be used for individual, group, all- Increases expansion capability to include all-zone broadcast to at-once emergency, and simultaneous 2-channel broadcasts. separate facilities. • Cascade Connection • 2-channel Broadcast Allo
Résumé du contenu de la page N° 6
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS SYSTEM EXAMPLES SYSTEM EXAMPLES 2 2 RESIDENCE SCHOOL Residence Outline School Outline KEY POINT KEY POINT • Remote-controlled Microphone Connection • Cascade Connection Allows remote microphones to be used for individual, group, all- Normal: Transmits individually to specific amplifiers. at-once emergency, and simultaneous 2-channel broadcasts. Emergency: All-zone announcement. • Additional Amplifier Connection • Remote-controlled Micro
Résumé du contenu de la page N° 7
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS SYSTEM EXAMPLES SYSTEM EXAMPLES 2 2 SHOPPING CENTER HOTEL Shopping Center Outline Hotel Outline KEY POINT KEY POINT • Remote-controlled Microphone Connection Public Address Paging System Allows remote microphones to be used for individual, group, all- • 2-channel Broadcast at-once emergency, and simultaneous 2-channel broadcasts. Transmit a message only to the zone that needs it. • Cascade Connection • Remote- controlled Microphone Conn
Résumé du contenu de la page N° 8
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS SYSTEM EXAMPLES SYSTEM EXAMPLES 2 2 COMPOUND BUILDING HOSPITAL Compoumd Building Outline Hospital Outline KEY POINT KEY POINT Public Address Paging System for whole facility Public Address Paging System • 2-channel Broadcast • 2-channel Broadcast Transmit a message only to the zone that needs it. Transmit a message only to the zone that needs it. • Cascade Connection • Cascade Connection Allows added amplifier capacity and additional sp
Résumé du contenu de la page N° 9
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WA-MA120N/WA-MA240N WA-MA120N/WA-MA240N VOLTAGE SELECTOR INSTALLATION CONNECTIONS switch Amplifier Important: PA AC Voltage Setting IN OUT • The Amplifier's output power cannot be increased if multiple Amplifiers (or WA-BA240N Booster Power • Before plugging the AC power plug into the mains, make sure the VOLTAGE Amplifier) are inputting and outputting the same signal "in parallel operation" because it will
Résumé du contenu de la page N° 10
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WA-MA120N/WA-MA240N WA-MA120N/WA-MA240N LINE1,2, INPUT2,3, REC OUT, INS IN/OUT Connections EMG,TEL PAGING, INPUT1 Connections • Use the connections shown below for a microphone or recording/playback equipment, effect device that is not equipped with • Use the connections shown below for emergency announcement equipment or PBX, microphone that is equipped with activation control (no-voltage make contact). acti
Résumé du contenu de la page N° 11
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WA-MA120N/WA-MA240N WA-MA120N/WA-MA240N Remote Microphone (WR-210AE) Connection Speaker Connection • Up to four Remote Microphone units can be connected. For multiple connections, priority connection between Remote • Use the connections shown below for connecting high-impedance or low-impedance loudspeakers. Microphones is required. For more information, consult the operating instructions of the Remote Micr
Résumé du contenu de la page N° 12
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WA-MA120N/WA-MA240N WA-MA120N/WA-MA240N Connecting to Override External Attenuation during All-zone Announcement 2-channel Broadcast Announcement Connection • For 2-channel broadcast announcement, connect the WA-BA240N as shown below. (Using 3-wire connection) WA-MA120N or WA-MA240N Amplifier To external attenuator ATT OVERRIDE 3-wire connection attenuator IN B WA-MA120N All-zone (H) or announcement ON OUT (H
Résumé du contenu de la page N° 13
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WA-MA120N/WA-MA240N WA-MA120N/WA-MA240N Battery Connection Zone Expansion Connection • Make sure the external battery is a 24 V Lead Acid battery (or two 12 V • You can expand the number of zones using multiple Amplifier units. batteries in series connection). Panasonic Corporation holds no • The illustration below shows the concept behind zone expansion. When connected this way the master Amplifier uses al
Résumé du contenu de la page N° 14
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WA-MA120N/WA-MA240N WA-MA120N/WA-MA240N Inter-area All-zone Announcement Connection • When Amplifiers are being used for separate operation in multiple areas, they can be connected using the ALL CALL BUS to Important 1 allow all-zone announcement from one area to all of the other areas. • The signal paths of an inter-area all-zone announcement during normal operation are shown below. In addition, each input d
Résumé du contenu de la page N° 15
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WA-BA240N WA-BA240N Line-level Equipment Connection Speaker Connection • Connect external devices (e.g. pre-amplifiers) to the LINE IN jack. The following illustration is a connection example with the • Use the connections shown below for connecting high-impedance or low-impedance loudspeakers. Mixing Power Amplifier (WA-MA120N or WA-MA240N). Caution: • Be sure to use the gold plated plugs (accessories) whe
Résumé du contenu de la page N° 16
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WA-BA240N WA-BA240N 100 V Input Connection Battery Connection • Connecting power amplifier output for high-impedance loudspeakers as shown below makes it possible to expand the number • Make sure the external battery is a 24 V Lead Acid of speakers through the Amplifier. battery (or two 12 V batteries in series connection). • The following illustration is a connection example with the Mixing Power Amplifier (
Résumé du contenu de la page N° 17
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WU-ZM001E WU-ZM001E 7. Replace the Amplifier's top cover. CONNECTIONS AND SETTINGS Fix the Amplifier's top cover with the screws, which Are removed in step1. Warning: • Be sure to turn off power before connecting or configuring settings. Be sure to turn off the device supplying power to the Sound Message Unit. Leaving power supplied creates the risk of electric shock and damage to equipment. Heat sink Inst
Résumé du contenu de la page N° 18
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WU-ZS001E WU-ZS001E SURVEILLANCE I/F Connector SURVEILLANCE I/F Connector Example Application: (1) Example Application: (2) – Switch Trigger/Status Indication – Backup Amplifier Connection After connecting to an external line as shown below, the switches can be used After connecting to an external line as shown below, the system can be configured to switch automatically to a backup amplifier to trigger vari
Résumé du contenu de la page N° 19
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WR-210AE WR-210AE Mixing Power Amplifier (WA-MA120N/240N) Connection CONNECTIONS Move the -22 dBV(RM)/-65 dBV switch on the Mixing Power Amplifier to the -22 dBV(RM) side. Connectable PA Systems Refer to the following table to determine the number of Remote Microphones that can be connected to the PA systems. PA System Name Number of devices that can be connected Name Type Remote Microphone (WR-210AE) Extensi
Résumé du contenu de la page N° 20
CONCEPT SYSTEM EXAMPLES CONNECTIONS PRODUCTS BLOCK DIAGRAMS CONNECTIONS CONNECTIONS 3 3 WR-210AE Individual Priority MEMO Making connection settings Refer to the following illustration for connecting up to 4 Remote Microphone. And the priority order of Remote Microphones depends on the order, in which they are connected to the Mixing Power Amplifier. Connect the high priority Remote Microphone’s priority output to the low priority Remote Microphone’s priority input. Do not connect the priority i