Rackmount Intelligent Pressure Scanner
User’s Manual
August 2009
NetScanner™ System
www.PressureSystems.com
Résumé du contenu de la page N° 2
© This User’s Manual is a copyright product of Pressure Systems, Inc., 2009 Permission is hereby granted to make copies and distribute verbatim copies of this manual, provided the copyright notice and this permission notice are preserved on all copies.
Résumé du contenu de la page N° 3
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© Chapter 1 General Information 1.1 Introduction This User’s Manual will: Explain the electrical and pneumatic pressure connections for the Model 98RK-1 Scanner Interface Rack and Model 9816 Rackmount Intelligent Pressure Scanners. Provide computer set-up instructions to make a proper Ethernet connection on most ® Windows -base
Résumé du contenu de la page N° 4
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© The NetScanner™ System is a comprehensive, distributed data acquisition system centered around PSI’s proven Intelligent Pressure Scanner technology. The rackmount configuration of this system is comprised of Model 98RK-1 Scanner Interface Racks, each housing up to eight (8) Model 9816 Rackmount Intelligent Pressure Scanners networked via the Ethernet interface
Résumé du contenu de la page N° 5
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© Data uploaded from the EEPROMs is used by the microprocessor to correct zero, span, linearity, and thermal errors. Digital temperature compensation of the piezoresistive sensors reduces thermal errors by a factor of ten or more over conventional sensor compensation. The microprocessor also controls the execution of on-line zero or span calibrations upon reque
Résumé du contenu de la page N° 6
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© The 98RK-1 Scanner Interface Rack features a gigabit switch that significantly increases processing capabilities and speed. System calibration consists of zero and span calibration only at any given temperature. Full thermal re-calibration is never necessary. Ease of use - modules have simple command sets and provide engineering units (EU) out
Résumé du contenu de la page N° 7
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© 1.3.3 Communication Interfaces All Intelligent Pressure Scanners provide digitally temperature compensated and linearized pressure data in engineering units through an Ethernet communications interface to a host computer. Model 9816 Intelligent Pressure Scanners have a 10Base-T Ethernet host communications interface using industry standard TCP/UDP/IP p
Résumé du contenu de la page N° 8
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© Chapter 2 Installation and Set Up 2.1 Unpacking and Inspection Before assembling the system, use the shipping bill as a reference to ensure that all parts have arrived. Pressure Systems takes no responsibility for equipment that is damaged during shipment. If containers are broken, ripped, or damaged, contact the transportation ca
Résumé du contenu de la page N° 9
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© 2.3 Connections and Setup 2.3.1 98RK-1 Chassis Connections with 9816 Scanners Ensure correct line voltage and that the Power Switch for the 98RK-1 is in the OFF position. Connect the 98RK-1 chassis to an adequate power receptacle and connect STEP 1 an Ethernet cable from the 98RK-1’s host port (TO HOST) to an optional 10/100/1000Base-T hub, switch, or d
Résumé du contenu de la page N° 10
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© Figure 2.1 Typical Hook-up Arrangement Using the 98RK-1 Scanner Interface Rack Page 8 www.PressureSystems.com
Résumé du contenu de la page N° 11
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© 2.3.3 Network Communications Hookup The 98RK-1 Scanner Interface Rack chassis has an Ethernet connector port on the rear of the unit through which all scanners in the rack may be connected to the network or the Ethernet card in your PC or work station. This port is labeled “ TO HOST” (using an RJ-45 connector). Similarly, every Model 9016, 9116, 9021,
Résumé du contenu de la page N° 12
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© ® Initial Network Screen for Windows XP With your mouse, right-click on the "Local Area Connection" icon. A drop-down menu STEP 7 will appear. Scroll down the menu and select (left-click) the "Properties" line. Scroll down the “Local Area Connection” tab to ensure that "Internet Protocol TCP/IP" STEP 8 is available. NOT
Résumé du contenu de la page N° 13
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© A screen example is shown here. With your mouse, right-click on the "Local Area Connection" icon. A drop-down menu STEP 9 will appear. Scroll down the menu and select (left-click) the "Properties" line. A screen example is shown on the next page. Scroll down the “Local Area Connection Properties” tab to ensure that "Internet STEP 10 Pro
Résumé du contenu de la page N° 14
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© If the TCP/IP protocol is not found, it must be installed. To install, select "Install" as STEP 11 shown on the "General" tab on the "Local Area Connection Properties" screen. Page 12 www.PressureSystems.com
Résumé du contenu de la page N° 15
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© Once the correct TCP/IP protocol is installed and verified for the proper Ethernet STEP 12 card, the IP address (under TCP/IP Properties), that is compatible with the pressure scanner(s), must be set. A typical screen example with IP and Subnet Mask addresses for a 9816 scanner is shown on the next page. Page 13 www.PressureSys
Résumé du contenu de la page N° 16
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© To set the PC address: Select "Use the following TCP/IP address." It is suggested that the IP Address read 200.xxx.yyy.zzz where xxx, yyy, and zzz are unique locations that do not match any other address on the network. (Check with your network administrator to see that the numbers chosen do not conflict with any other STEP 13 addresses on the network
Résumé du contenu de la page N° 17
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© Connect the Ethernet cable between the 98RK-1 “TO HOST” RJ-45 connector and STEP 14 the Ethernet card of your host computer. After you set the IP address and the subnet mask, click “OK”. You may then be prompted to re-start your computer so that the inputs will be recognized. The host computer and each module must have a unique Ethernet Hardware
Résumé du contenu de la page N° 18
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© Turn the 98RK-1 power switch ON and wait approximately thirty (30) seconds for the scanners to perform self-diagnostics. The scanners automatically upload the STEP 16 calibration data stored within each transducer at start-up. Newly installed transducers are automatically ready to be used without further calibration. Select (double click) the executable
Résumé du contenu de la page N° 19
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© NUSS Initial Screen Once NUSS is selected, the Network Status Screen (shown above) appears. Note that a "Querying Network" message briefly appears, and then the Nodes on Network box will automatically display the each NetScanner module hooked into the network. It also shows their serial number, IP address, and whether or not they are acti
Résumé du contenu de la page N° 20
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual© Connect to any module. (When a connection has been established, the top of the module icon will turn yellow.) STEP 18 Select (left click) the module's icon in the Node map. Right-click on the module's icon (in either the Node Map or the description box), and select (left click) on "Connect" in the pull-down menu that appears. (See screen depiction below.)