Résumé du contenu de la page N° 1
000000
i1860 Scanner
Installation Planning Guide
Eastman Kodak Company
343 State Street
Rochester, NY 14650 USA
© Kodak, 2006. TM: Kodak.
PN 000000
www.kodak.com/go/docimaging A-61578
GUIDE COVER
M. DE MEYER-CMO US CD+U GRAPHIC DESIGN
05.03.06
FONTS USED IN THIS ARTWORK:
WHITNEY FAMILY
COLORS USED IN THIS ARTWORK:
SPOT COLORS BLACK, KODAK YELLOW, KODAK RED
Résumé du contenu de la page N° 2
Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Warning labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety and regulatory agency approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Environmental information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 European Union . . . . . . . . . . . . . . . . . . . . . . . . . .
Résumé du contenu de la page N° 3
Safety Information Warning labels CAUTION: Moving parts, avoid contact. CAUTION: Hot surface, avoid contact. Safety and regulatory The Kodak i1860 Scanner conforms to all applicable national and international product safety and electronic emission regulatory agency approvals requirements. This includes, but is not limited to, the following: Country or Region Safety Approval Safety Mark Electromagnetic Compatibility EMC Mark Australia/New AS/NZS CISPR 22 Class A C-Tick Zealand Canada CAN/CSA-C2
Résumé du contenu de la page N° 4
EMC statements Compliance with regulations governing radio frequency emissions requires that the installation of your Kodak i1860 Scanner use the shielded data cable provided. Any data cable the user may choose to substitute also must be shielded to assure continued compliance. United States This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against
Résumé du contenu de la page N° 5
Korean Please note that this equipment has obtained EMC registration for commercial use. In the event that it has been mistakenly sold or purchased, please exchange it for equipment certified for home use. European Union WARNING: THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES. Acoustic emission Maschinenlärminformationsverordnung – 3, GSGV Der arbeitsplatzbezogene Emissionswert b
Résumé du contenu de la page N° 6
Preparing the Site The Kodak i1860 Scanner is a new high speed, dual stream scanning platform which provides advanced image processing and superior throughput. The i1860 Scanner is designed to handle mixed document batches for any production scanning workflow. This manual provides site specification and installation information for the Kodak i1860 Scanner. IMPORTANT:The Kodak i1860 Scanner must be uncrated and installed by a qualified Kodak Service Representative. Do not open the packagin
Résumé du contenu de la page N° 7
Delivery day On delivery day: • Inspect the scanner packaging for any damage. • Move the scanner to the unpacking area. • Notify Kodak of a successful delivery. Installation day • On installation day, in addition to the Kodak Field Engineer, the following people need to be available: - Site Computer Administrator -Integrator - All scanner operators. If there are more than three operators, an additional fee may be charged for extra operators. Contact Kodak prior to training. • The Kodak Field
Résumé du contenu de la page N° 8
• Any combustible or corrosive atmosphere caused by volatile liquids or solvents. • Heat sources, such as windows, baseboard heating units, heat ducts, space heaters, or any heat-generating equipment. • Transmitted interference, such as that generated by electronic air cleaners, communication transmitters, radar (FAA and military), or power lines. • Locate air conditioning outlets so the scanner will receive optimum air circulation. • Avoid carpets and any static-generating areas. Dimension
Résumé du contenu de la page N° 9
Requirements Operating requirements The scanner can operate in a typical office environment under the following conditions: Temperature range: 15 to 35 °C (59 to 95 °F) Relative humidity: 15 to 76% (dry bulb) Static electricity — buildup of static electricity near the i1860 Scanner may cause operating problems. If the area is carpeted, it is recommended that the carpet is treated with an anti-static material or a conductive static mat is used. Line voltage and Acceptable operational voltage
Résumé du contenu de la page N° 10
AC power quality and In some locations, even though recommended wiring practices have been followed, the power reaching the scanner may exhibit unstable conditioning power quality characteristics. System errors and intermittent data loss could result. Power conditioning equipment may be required to overcome the power quality problems. Kodak can make arrangements for an on-site power analysis in an area with exceptionally unstable power at an additional cost. Consult with your electrical c
Résumé du contenu de la page N° 11
System requirements Following is the minimum recommended system configuration to run a Kodak i1860 Scanner. NOTE: The actual performance of the system depends on the scanning application, choice of scanning parameters, and the host computer configuration. If the scanner is not performing at the optimal speed, a faster computer and/or more RAM may be necessary to obtain the rated throughput. • Intel PC (or compatible) with a Pentium IV 2 GHz processor • An available PCI slot (for FireWire c
Résumé du contenu de la page N° 12
Installation Procedures Follow the instructions for installing the 1394a (FireWire) card and the Kodak Driver Software before you connect the scanner to the host computer. If you want, Kodak Service will install the 1394a (FireWire card) in the host computer. Kodak takes no responsibility for problems that may be caused by the installation of this hardware. If the host computer has a built-in 1394a (FireWire) port, the i1860 Scanner can be connected using this interface but it is not recom
Résumé du contenu de la page N° 13
Installing the FireWire A six-pin connector is provided on the rear panel of the scanner for FireWire connectivity. cable 1. Plug the end of the cable with the right angle into the scanner. 2. Connect the other end of the cable into the 1394a card outlet in the host computer. Be sure that it is installed correctly and properly seated. CAUTION: DO NOT FORCE THE CONNECTOR. If the cable is not properly connected, it could cause damage to the scanner. Attaching the power cord The Kodak i1860 S
Résumé du contenu de la page N° 14
Supplies and Consumables The following supplies are available. Order them in the United States by calling DI Supply at 1-888-247-1234 or contact your local Kodak Reseller. Outside of the United States, contact your local Kodak dealer. Supplies/Consumables CAT No. Kodak Feeder Consumables Kit for i600/i1800 Series 108 4755 Scanners Kodak Feeder Kit for Ultralightweight Paper for i600/i1800 896 5279 Series Scanners Kodak Extra-Large Feeder Consumables Kit for i600/i1800 842 6157 Series Scanners
Résumé du contenu de la page N° 15
Delivery and Installation Setup The period between the placement of the order and the installation of the equipment may vary. During this time, you should prepare the installation site. This will help prevent unexpected problems on installation day NOTE: All site preparation should be completed in advance of the equipment delivery. Kodak must be notified in advance of any special site requirements. These requirements include special delivery procedures, time restrictions and security clear
Résumé du contenu de la page N° 16
Claims process The following steps should be taken before making a claim. Outside the United States • Contact your local Kodak dealer or Kodak representative. Within the United States • Save all packing materials from the carton in question. • Do not move damaged equipment any farther than necessary (equipment should be moved no farther than an immediately adjacent area). • Do not attempt any repairs until authorized by Kodak’s Equipment Customer Relations in Rochester, New York. • Obtain and
Résumé du contenu de la page N° 17
Training Scanner operation and maintenance training is provided by the Kodak Field Engineer. NOTE: Training on the host application is not provided by Kodak. Supporting The following documentation is available to support the Kodak i1860 Scanner: documentation • User’s Guide, A-61555 — provides basic user instructions for using the Kodak i1860 Scanner including cleaning and customer- replaceable part procedures. • Quick Tips Guide, A-61556 — is a summary of this User’s Guide and is intended
Résumé du contenu de la page N° 18
Standard Maintenance Eastman Kodak Company (“Kodak”) and you, the customer (“Customer”) agree that the following terms and conditions will apply to Service Terms and the provision of services by Kodak for the products defined below Conditions located in the United States, Hawaii and Alaska (where a ten percent (10%) premium applies). Generally, the mainframe and all components of a Product that are mechanically, electronically, or remotely interconnected must be inspected, tested and adju
Résumé du contenu de la page N° 19
I. keep the site environmental ranges within the specifications set forth by the manufacturer of the relevant Product; J. provide continuous and appropriate resource availability during problem resolution. NOTE: Failure to meet these obligations may result, at Kodak’s sole option, in the imposition of additional charges at prevailing Per-Call rates. 2.1 Customer Software. Prior to service commencing on computers with hard drives, Customer is responsible for creating a back-up copy of the
Résumé du contenu de la page N° 20
D. Extended Hours. Depending upon local service capabilities, available extended hour plans include 5-, 6-, and 7-day, 8-, 16-, and 24-hour options at additional cost. Kodak will use commercially reasonable efforts to provide Service outside of Agreement Hours as shown below. Any such service performed will be billed at prevailing Kodak Per-Call Overtime rates. E. Holidays. Services will not be provided on holidays (including, but not limited, to New Years, Memorial, Independence, Labor,