Résumé du contenu de la page N° 1
SERVICE MANUAL
GAS RESTAURANT RANGE
EG24, 36, 48, 60, 160 AND 260
MODEL
EG24 ML-52486
EG36 ML-52487
EG48 ML-114956
EG60 ML-52488
EG160 ML-52489
EG260 ML-52490
EG36
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791
FORM 31054 Rev. A (5-98)
Résumé du contenu de la page N° 2
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUT-OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR G
Résumé du contenu de la page N° 3
GAS RESTAURANT RANGE MODELS EG60 EG160 EG260 EG48 EG24 EG36 PL-53006 – 4 –
Résumé du contenu de la page N° 4
SERVICE MANUAL GAS RESTAURANT RANGES INDEX PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE DESCRIPTION PAGE SERVICE NOTATIONS 6 UNITS MOUNTED ON CASTERS 7 SERVICING SIMPLE CHECKS AND ADJUSTMENTS 7-10 GAS CONNECTIONS 11, 12 TESTING THE GAS SUPPLY SYSTEM 12 ORIFICE SIZE REQUIREMENTS FOR DIFFERENT ELEVATIONS 12 PILOT LIGHTING AND ADJUSTMENTS 13-17 THERMOSTAT ADJUSTMENTS 18-21 REGULATOR CHECK, ADJUSTMENT, INSTALLATION 22-24 STANDARD OVEN & GRIDDLE THERMOSTAT REPLACEMENT 24-27 OVEN PILOT CHECK, REPLACEM
Résumé du contenu de la page N° 5
DEDICATED TECHNICAL SERVICE HOT LINE- (1-502-778-2791) SERVICE NOTATIONS: 1. The procedures outlined in this manual are to be performed only by Vulcan-Hart authorized service representatives. 2. An authorized Vulcan-Hart service representative is one who is familiar with Vulcan equipment and who has been endorsed by Vulcan-Hart Company to service the equipment. All authorized service personnel are required to stock a minimum amount of parts and should be equipped with a complete set of wiring di
Résumé du contenu de la page N° 6
UNITS MOUNTED ON CASTERS Units mounted on casters utilizing a flex hose and quick-disconnect must be installed with a restraining device. The restraining device must be connected at all times. If disconnection of the device is necessary, turn off the gas supply before disconnection. Reconnect the restraint before turning the gas supply on and returning the unit to its original installation position and before beginning unit operation. SERVICING SIMPLE CHECKS AND ADJUSTMENTS The following is a li
Résumé du contenu de la page N° 7
SERVICING SIMPLE CHECKS AND ADJUSTMENTS (Cont.) 2. Oven Door Turnbuckle NOTE: For the 24L units, refer to procedure outlined under 2A. If the oven door is not closing properly, the door turnbuckle may require adjustment. To adjust the turnbuckle, flip down the lower front kick panel. The turnbuckle is connected between the right- and left-hand door springs (Fig. 1). With your hand, rotate the cast center piece of the turnbuckle two rotations at a time, then check the door tension. Repeat thi
Résumé du contenu de la page N° 8
W A H C R S A T SERVICING SIMPLE CHECKS AND ADJUSTMENTS (Cont.) 3. Pilot Flame Height TOOLS REQUIRED: Standard flat blade screwdriver. Top Burners: To adjust pilot flame height of the unit top burners, locate the pilot adjustment screws found on the front manifold pipe. It is not necessary to remove the manifold cover, as adjustment access holes have been provided in the panel. With screwdriver, turn the adjustment screw of the pilot valve experiencing the pilot flame height problems (Fig. 3).
Résumé du contenu de la page N° 9
SERVICING SIMPLE CHECKS AND ADJUSTMENTS (Cont.) 2. With screwdriver, adjust pilot key (located under pilot adjustment cap) to provide the proper size flame. 3. Replace pilot adjustment cap. NOTE: If unit still is not heating correctly, refer to THERMOSTAT ADJUSTMENTS on Page 18. 4. Air Shutter Adjustment TOOLS REQUIRED: Standard flat blade screwdriver. The efficiency of the oven depends on a delicate balance between the air supply and the volume of gas. Whenever this balance is disturbed, poor
Résumé du contenu de la page N° 10
GAS CONNECTIONS CAUTION: All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases. Each unit is factory-equipped with the type gas specified on the rating plate. The installation gas connection is a 3 ⁄4" (19mm) 14 FPT thread ANSI schedule #40 standard pipe. Codes require that a gas shutoff valve be installed in the gas line ahead of the range. Standard units are equipped with fixed burner orifices which coincide with the proper unit operation
Résumé du contenu de la page N° 11
GAS CONNECTIONS (Cont.) NOTE: A leak limiter is supplied with every regulator to allow excess gas pressure to escape. Do not obstruct leak limiter on gas pressure regulator as obstruction may cause regulator to malfunction. WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME. After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air. TESTING THE GAS SUPPLY SYSTEM 1 IMPORT
Résumé du contenu de la page N° 12
PILOT LIGHTING AND ADJUSTMENTS NOTE: Although pilot lighting procedures are to be performed by both installation and operation personnel, only the installation/service personnel should attempt to make any pilot, burner, or temperature adjustments to this unit. The operation personnel are authorized only to perform the procedures for pilot lighting. All adjustment procedures associated with pilot lighting must be performed by an authorized Vulcan-Hart installation or service person. While perform
Résumé du contenu de la page N° 13
PILOT LIGHTING AND ADJUSTMENTS (Cont.) OPEN TOP BURNERS 1. Turn main gas supply “ON”. 2. Wait 30 seconds and, using a taper, light the open top pilot (Fig. 10). Fig. 10 3. If pilot fails to light, turn main gas supply “OFF”. Wait 5 minutes and repeat the above procedures. 4. Turn one open top burner valve “ON” to remove air from the gas line. Turn burner “OFF” when gas begins to flow. OPEN TOP BURNER ADJUSTMENTS TOOLS REQUIRED: Standard flat blade screwdriver. 1. After pilot is lit, turn open t
Résumé du contenu de la page N° 14
PILOT LIGHTING AND ADJUSTMENTS (Cont.) BROILER/GRIDDLE 1. Turn main gas supply “ON”. 2. Wait 30 seconds and, using a taper, light broiler/griddle pilot (see Fig. 9). 3. If pilot fails to light, turn main gas supply “OFF”. Wait 5 minutes and repeat Steps 1 and 2. 4. Turn burner valve “ON” to purge air from the lines. Turn burner valve “OFF” when gas begins to flow. BROILER/GRIDDLE ADJUSTMENTS TOOLS REQUIRED: Standard flat blade screwdriver, lighter taper. Adjust pilot burner flame, if necessary,
Résumé du contenu de la page N° 15
PILOT LIGHTING AND ADJUSTMENTS (Cont.) 2. Light pilot by depressing the reset button located behind the kick panel (Fig. 12). Light pilot and continue to hold reset button in for 1 minute. If pilot fails to light, turn main gas supply “OFF” and wait 5 minutes before repeating Step 2. 3. After pilot is lit, turn the temperature dial to the desired setting. Nightly Shutdown: Turn oven burner valve “OFF”. Complete Shutdown 1. Turn oven burner valve “OFF”. 2. Turn main gas supply “OFF”. Fig.
Résumé du contenu de la page N° 16
PILOT LIGHTING AND ADJUSTMENTS (Cont.) OVEN BURNER ADJUSTMENTS NOTE: These procedures should be performed only by a qualified Vulcan-Hart service representative. TOOLS REQUIRED: Standard flat blade screwdriver. All Restaurant Range series units equipped with pressure regulator and fixed orifices have been adjusted at the factory and should require no further adjustments. However, the efficiency of the range depends on a delicate balance between the air supply and the volume of gas. Whenever th
Résumé du contenu de la page N° 17
THERMOSTAT ADJUSTMENTS NOTE: These procedures should be performed only by a qualified Vulcan-Hart service representative. STANDARD OVEN Although the unit thermostats are factory positioned to their proper setting, it is not unusual for the thermostat to be knocked out of adjustment during shipment. If the oven or griddle heat response seems to be lacking after burner air shutter adjustments have been checked, perform the following adjustments. NOTE: There are two possible conditions of the therm
Résumé du contenu de la page N° 18
THERMOSTAT ADJUSTMENTS (Cont.) 3. Light the burner. Turn the dial to the highest set temperature. 4. After 10 minutes, turn the dial clockwise to the point slightly beyond the first mark on the dial (shown by an “X”). 5. Remove the dial and sleeve (Fig. 17). Fig. 17 Fig. 18 6. With a screwdriver, turn the left-hand bypass adjustor screw counterclockwise to increase the flame, clockwise to 1 decrease it, until the flame appears to be ⁄8" (3.175mm) over the entire burner area (Fig. 18). 7.
Résumé du contenu de la page N° 19
THERMOSTAT ADJUSTMENTS (Cont.) 3. Allow unit to heat until the burner flame is heard cutting “OFF”. Wait about 10 minutes until the burner flame has cycled “ON” and “OFF” several times. Then compare the test instrument reading with the dial setting. If the reading is within ± 15°F (-9.4°C) of the dial setting, its calibration is correct. If reading is not within this temperature window, then recalibrate by performing Steps 4 through 13. 4. Pull the dial straight off the dial shaft (see Fig. 17
Résumé du contenu de la page N° 20
THERMOSTAT ADJUSTMENTS (Cont.) 10. To recalibrate, hold the thermostat dial in place. Insert screwdriver into dial shaft to engage the calibration stem adjustment screw (Fig. 20). Push inward (do not turn stem). Fig. 20 11. While holding stem calibration screw in place, turn thermostat dial until it is set on the actual temperature shown by the testing device (Fig. 21). Fig. 21 12. Release the calibration screw and reinstall the dial insert. 13. Set the dial to 450°F (232.2°C) and recheck temper