Résumé du contenu de la page N° 1
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
Résumé du contenu de la page N° 4
CONTENTS Title page 1. SAFETY INFORMATION ................................................................................................ 1 2. SPECIFICATION ............................................................................................................. 2 2-1 General Specification ........................................................................................... 2 2-2 Electrical Specification........................................
Résumé du contenu de la page N° 5
3-19 How to ConnectsTL-(A37) Analog Output Cable.............................................. 14 3-20 Setup Process Transducer (4-20mA) Mode ..................................................... 15 4. BATTERY & FUSE REPLACEMENT ........................................................................... 16 4-1 Battery Check & Replacement ........................................................................... 16 4-2 Fuse Replacement ............................................................
Résumé du contenu de la page N° 6
1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. The meter analog input protection voltage range is 24V ,current range is 250V/0.5A Fuse(MAX) , maybe damage forever if overload. Environment conditions: Altitude up to 2000 meters Indoor use Relatively humidity 10~80%RH Operation temperature 0 〜 40℃ (32~104℉) Maintenance & Clearing Repairs or servicing not covered in this manual should only be performed by qual
Résumé du contenu de la page N° 7
2. SPECIFICATION 2-1 General Specification 1 Display : 3 LCD 2 LCD symbols: 13 4 2 24265 6 7 16 18 15 19 8 11 12 28 13 17 20 21 10 23 14 9 25 27 22 (Fig-1) 1. SET In setting mode symbol. : 2. RS-232 In RS-232 transmission mode symbol. : DATE Show the date of real time clock. : Show mode : month – day – year. 3. – – TIME Show the time of real time clock. : Show mode is hour : minute : second. 4. : : START Show the start time of record / print. : Show mode is hour : minute : second. 5.
Résumé du contenu de la page N° 8
STOP :Show the stop time of record / print. 6. : : INTV :Show the interval time of record / print. 7. : : 8. :DC test symbol. 9. :AC test symbol. 10. :Low battery indicator. 11. mVA :Analog test indicate unit. 12. G :The printer working in the graphic mode. 13. T :The printer working in the text mode. 14. :Memory record indicator. 15. MAX :MAX Analog input indicator. 16. MIN :MIN Analog input indicator. 17. LUX :LUX unit indicator. 18. Fc :Feet-candle unit indicator.
Résumé du contenu de la page N° 9
24. HI ALARM :Hi alarm indicator. 25. LO ALARM :Lo alarm indicator. 26. HiHi ALARM :Hi Hi alarm indicator. 27. LoLo ALARM :Lo Lo alarm indicator. 28. ℃ ,℉ :Temperature unit indicator. - 29. Over Load Indicator :Show or 。 Other parts: Input Protection :Voltage range 24V ,current range 0.5A/250V Fuse(MAX) Operation Temperature:0℃〜40℃( 32℉〜104℉ ) & (10~ 80% RH) and Humidity Conserve Temperature:-10℃〜60℃(14℉〜140℉) & (10~70% RH) and Humidity Dimensions :About 250 (L) × 100 (W) ×
Résumé du contenu de la page N° 10
2-2 Electrical Specification Analog test range :DCV/ACV:2V,200mV DCA: 20mA Accuracy :(at 23℃±5℃,below 80%RH) DC(1%rdg+3dgts) AC(1%rdg+5dgts) at (50~450Hz) Resolution :200mV/2V range is 0.1mV/1mV 20mA range is 0.01mA A / D Sample Rate:2.5 times/sec Power Source :6 pcs 1.5V,# 3 battery or 9V, DC adaptor (inside negative, outside positive) Battery Life :Approx. 100 hours (without printing) Printer :Thermal printer (EPL1902 of Panasonic) MEMORY :60000 records (up to 130000 records
Résumé du contenu de la page N° 11
3. PARTS & CONTROLS 3-1 The Name of Each Parts and Positions: 200mV 2V 200mV 2V 20mA ¢X C ¢X F Lux Fc dB ¢XRH A A ¢X HiHi Hi LoLo Lo G T DATE TIME START STOP INTV 0 13 2 45 6 78 9 , 3 SETTING RANGE UNIT FEED MAX SETUP LINE MIN CLOCK ALARM PRINT RECORD , 1 TRIGGER , 3 CONSECUTIVE mA COM V 20mA 60V MAX 24V FUSED MAX 600V (Fig-2) 6
Résumé du contenu de la page N° 12
200mV C / F Toggle button for ( 200mV, ℃/℉, HiHi, DATA) HiHi 1. DATA and digit “ o ”. 0 2V Lux/Fc Hi Toggle button for ( 2V, Lux/ Fc, Hi, TIME) and 2. TIME digit “ 1/2/3 ”. 1/2/3 200mV dB LoLo Toggle button for ( 200mV, dB, LoLo, START) 3. START and digit “ 4/5/6 ”. 4/5/6 2V %RH Lo Toggle button for ( 2V, %RH, Lo, STOP) and 4. STOP digit “ 7/8/9 ”. 7/8/9 20mA A/ Toggle button for ( 20mA, A / A, G/T 5. G / T, INTV ) button and “ ” right shift INTV function. 3'SETTING Press and
Résumé du contenu de la page N° 13
RANGE Feed paper in normal mode, range function in 7. FEED setting mode. LINE UNIT MAX/MIN function in normal mode “ UNIT ” 8. MAX function in setting mode. MIN In normal mode, press 1 sec is trigger print CLOCK function, press and hold for 3 sec is start/stop 9. PRINT consecutive print function, but in setting mode will be “ clock ” function. In normal mode, press 1 sec is trigger record ( ALARM MAX 255 times), In setting mode is “ alarm ” 10. function, press and hold over 3 sec is start/sto
Résumé du contenu de la page N° 14
3-2 Power Status : As battery power is not sufficient, the , will be shown on LCD replace with six new 1.5V batteries is required. 3-3 Quick Manual for Easy Set-up STEP1 STEP2 STEP3 STEP4 STEP5 Press to Choose one from specified Reconfirm Push this Select one. return button 3 second. function Bar. input setting. normal. 200mV 2V 200mV 2V 20mA RANGE RANGE F c LUX / FC A / A dB %RH UNIT UNIT SETUP SETUP DATE TIME START STOP INTV CLOCK CLOCK Hi LoLo HiHi Lo G / T ALARM ALARM a. You could
Résumé du contenu de la page N° 15
3'SETTING 4. DCV 200mV Test setting sequence:Press and hold for 3 RANGE RANGE sec press press 200mV press 3'SETTING press , to end setting mode. 3'SETTING 5. DCA 20mA Test setting sequence:Press and hold for 3 RANGE RANGE sec press press 20mA press 3'SETTING press , to end setting mode. 3-5 UNIT Setting Step: 3'SETTING 1.℃/℉ Setting step:press and hold for 3 sec press UNIT C/ F UNIT press change℃/℉ press 3'SETTING press , to end setting mode. 3'SETTING 2. Lux
Résumé du contenu de la page N° 16
ALARM right shift button setting “ALARM" press press 3'SETTING , to end setting mode. 3'SETTING 3. LOLO ALARM Setting step:press and hold for 3 sec into ALARM LoLo setting mode press press assort 0~9 ALARM number right shift button setting “ALARM" press 3'SETTING press , to end setting mode. 3'SETTING 4. LO ALARM Setting step:press and hold for 3 sec into ALARM Lo setting mode press press assort 0~9 ALARM number right shift button setting “ALARM" press 3'
Résumé du contenu de la page N° 17
3'SETTING press to end setting mode. 3-9 Print Mode Setting Step: 3'SETTING Printer work mode setting sequence:press and hold for 3 ALARM G/T sec into setting mode press press change 3'SETTING G/T MODE press , to end setting mode. 3-10 Clear Record Step: + Press Power ON in the same time RECORD The LCD should display “dEL” 3-11 Disable Start、Stop、Intv and Setting Step: 1.Disable START、STOP、INTV sequence:press and hold START 3'SETTING for 3 sec into setting mode press disable
Résumé du contenu de la page N° 18
3-15 Record / Print Start and Step Operation Method: (1). Start way : PRINT RECORD 1. Trigger Record / Print : in general mode press or one second. 2. Consecutive Record/Print : Automatic mode : a). Into setting mode, setting Start/Stop/Into/Time. b). Chose automate consecutive Record/Print (by 3-13 setting way) c). Back to general mode, on LCD or should be repeat. Hand setting mode : a). Into setting mode, disable Start, Stop, Intv. (by 3-11 stop way) b). Into setting mode, setting I
Résumé du contenu de la page N° 19
3-18 Scale Change in Graphic Mode HiHi Hi Lo LoLo Scale change by alarm setting ALARM ALARM ALARM ALARM No change No change No change No change Change scale by HiHi Hi ALARM Change scale by HiHi Lo ALARM Change scale by HiHi LoLo ALARM Change scale by Hi Lo ALARM Change scale by Hi LoLo ALARM Change scale by Lo LoLo ALARM Change scale by HiHi Lo ALARM Change scale by HiHi LoLo ALARM Change scale by HiHi LoLo ALARM Change scale byHi LoL
Résumé du contenu de la page N° 20
200mV 2V 200mV 2V 20mA ¢X C ¢X F Lux Fc dB ¢XRH A A HiHi Hi LoLo ¢X Lo G T DATE TIME START STOP INTV 0 1 2 3 4 5 6 7 8 9 , 3 SETTING RANGE UNIT FEED MAX SETUP LINE MIN CLOCK ALARM PRINT RECORD , 1 TRIGGER , 3 CONSECUTIVE mA COM V 20mA 60V MAX 24V FUSED MAX 600V Model Connecting way (DC Input) Connecting way (AC Input) Remark Red lead connect to (V), TES-1300 No (AC input) Black lead connect to (COM) Red lead connect to (V), TES-1302 No (AC input) Black lead connect to (COM) Red lead connect to (