Résumé du contenu de la page N° 1
SNMP-NV6
UPS SNMP Card
(Web-Based monitoring SNMP Card)
User’s Manual
Résumé du contenu de la page N° 2
SNMP-NV6 About this manual This manual contains information about the installation and the operation of the SNMP-NV6 SNMP card. Save this Manual This manual contains instructions and warnings that should be followed during the installation, operation and storage of this product. Failure to heed these instructions and warnings will void the product warranty. Electromagnetic Interference This is a Class A product. In a domestic environment, this product might cau
Résumé du contenu de la page N° 3
SNMP-NV6 Table of Contents 1. Overview ........................................................................................................... 5 1.1 Features ..................................................................................................... 5 1.2 Package Contents ...................................................................................... 6 2. Description .......................................................................................................
Résumé du contenu de la page N° 4
SNMP-NV6 5.3.2.5 Power Fail/Restore Simulation ........................................................... 21 5.3.3 Weekly Schedule................................................................................... 21 5.3.4 Specific Schedule.................................................................................. 22 5.4 Administration........................................................................................... 22 5.4.1 User Manager.....................................
Résumé du contenu de la page N° 5
SNMP-NV6 1. Overview SNMP-NV6 card is an interface between the UPS and the network. It can obtain the information from a UPS and issue commands to it. SNMP-NV6 card supports two kinds of protocols – SNMP and HTTP for user access. Through the SNMP NMS and Web Browser, the user can setup the SNMP-NV6 card obtain information from the UPS and issue commands to UPS. SNMP-NV6 card also provides shutdown software that operates with various Operating Systems that can link to the SNMP-NV6
Résumé du contenu de la page N° 6
SNMP-NV6 1.2 Package Contents The SNMP-NV6 card package contains the following items. Quantity Item 1 SNMP-NV6 SNMP Card 1 CD 1 RJ45 to DB9 serial cable 1 Quick Install 1 Product Warranty Card 2. Description The SNMP-NV6 card’s components are described as below. Network Port LED Indicators Console Port Reset Button Dipswitch 2.1 Ports Item Description Network Port Connect to the Network. LED Indicators Indicate operational status. Console Port Connect to a
Résumé du contenu de la page N° 7
SNMP-NV6 2.1.1 LED Indicators No. Yellow LED Green LED Description 1 --- OFF Hardware or network error 2 Flashing (1sec) --- UPS is disconnected Without Temp/Humidity probe 3 Flashing (50 ms) ON Normal operation With Temp/Humidity probe 4 Flashing (50 ms) Flashing (50 ms) Normal operation Flashing (50 ms) ON Temp/Humidity probe is 5 disconnected 2.1.2 Dipswitch Settings No. Dip1 Dip2 Description 1 OFF OFF Normal operation 2 OFF ON Pass Through Mode 3 ON OFF Sensor
Résumé du contenu de la page N° 8
SNMP-NV6 4. Configuration Methods The easiest way to configure the SNMP-NV6 card is to run the EzSetting program, which you can find on the provided CD. Once you have configured the essential network parameters successfully, you can launch a Web Browser or telnet to the SNMP-NV6 card to execute more detailed configuration. 4.1 Configure the SNMP-NV6 card by EzSetting 1. Prepare a workstation (Microsoft Windows 2000, 2003, 2008, XP, Vista, Win7 or later). 2. Make sure both of the dipswit
Résumé du contenu de la page N° 9
SNMP-NV6 9. Select the SNMP-NV6 card in the Device List and then click on the Modify button. Enter the account and password. The default account and password are admin and password respectively. 10. Click on the Configuration button and then configure the essential network parameters. 4.2 Configure the SNMP-NV6 card through COM Port 1. Prepare a workstation (Microsoft Windows 2000, 2003, 2008, XP, Vista, Win7 or later). 2. Use
Résumé du contenu de la page N° 10
SNMP-NV6 6. Set both of the dipswitches of the SNMP-NV6 card to ON position (configuration mode). After the message appears on the screen, key in the account (default account is admin’) and password (default password is password). Then the SNMP-NV6 card’s Main Menu will appear on the screen. Refer to section 4.4 Configure the SNMP-NV6 card via Text Mode for more information. 4.3 Configure the SNMP-NV6 card through Telnet 1. Connect the SNMP-NV6 card to the network. 2. Prepare a worksta
Résumé du contenu de la page N° 11
SNMP-NV6 4.4.1.1 User Manager +========================+ | User Manager | +========================+ RADIUS [1]. RADIUS Auth: Disable [2]. Server: [3]. Secret: [4]. Port: 1812 ---------------- Local Auth Administrator [5]. Account: admin [6]. Password: ******** [7]. Limitation: Only in This LAN Device Manager [8]. Account: device [9]. Password: ******** [a]. Limitation: Only in This LAN Read Only User [b]. Account: user [c]. Password: ******** [d].
Résumé du contenu de la page N° 12
SNMP-NV6 4.4.1.2 TCP/IP Setting +========================+ | TCP/IP Setting | +========================+ [1]. IPv4 Address: 192.168.001.100 [2]. IPv4 Subnet Mask: 255.255.255.000 [3]. IPv4 Gateway IP: 192.168.001.254 [4]. IPv4 DNS or WINS IP: 192.168.001.001 [5]. DHCPv4 Client: Enable [6]. IPv6 Address: fe80::230:abff:fe25:900 [7]. IPv6 Prefix Length: 64 [8]. IPv6 Gateway IP: :: [9]. IPv6 DNS IP: :: [a]. DHCPv6: Enable [b]. Host Name (NetBIOS): SNMP-NV6 [c]. System Con
Résumé du contenu de la page N° 13
SNMP-NV6 4.4.1.3 Network Parameter +========================+ | Network Parameter | +========================+ [1]. HTTP Server: Enable [2]. HTTPS Server: Enable [3]. Telnet Server: Enable [4]. SSH/SFTP Server: Enable [5]. FTP Server: Enable [6]. Syslog: Enable [7]. HTTP Server Port: 80 [8]. HTTPS Server Port: 443 [9]. Telnet Server Port: 23 [a]. SSH Server Port: 22 [b]. FTP Server Port: 21 [c]. Syslog Server1: [d]. Syslog Server2: [e]. Syslog Server3: [f]. Syslog Serv
Résumé du contenu de la page N° 14
SNMP-NV6 4.4.1.4 Time Server There are two ways to set the SNMP-NV6 card’s current time and date. One is to set the system time manually, but this is not the best way. The ideal way is to set up a timeserver. The SNMP-NV6 card does support SNTP, which is supported by Windows XP. To configure a Windows PC to act as a timeserver, please install the Simple TCP/IP Services from the Add/Remove Windows Components. +========================+ | Time Server | +==================
Résumé du contenu de la page N° 15
SNMP-NV6 5. Web Interface 5.1 Run a Web Browser 1. Make sure that you have a TCP/IP network already installed. 2. Start your Web Browser. Enter http://host_name or http://ip_address in the address bar for the plain web transmission or https://host_name or https://ip_address for the encrypted web transmission. The SNMP-NV6 card will then ask for your user name and password. After keying in the correct user name and password, the SNMP-NV6 card’s Home Page will appear on the screen.
Résumé du contenu de la page N° 16
SNMP-NV6 5.2.1 UPS Properties This page gives a snapshot of all the principal UPS parameters. The values will update automatically. To set the refresh time, select the menu Administration – Web – Web Refresh Period. 5.2.2 Battery Parameters This page displays a list of the UPS battery parameters. Page 16
Résumé du contenu de la page N° 17
SNMP-NV6 5.2.3 In/Out Parameters Select In/Out Parameters from the UPS Information on the main menu to get a list of the UPS input, and output parameters. 5.2.4 Identification Select Identification from the UPS Information menu to get a list of the UPS information. Page 17
Résumé du contenu de la page N° 18
SNMP-NV6 5.2.5 Status Indication This page lists the UPS events and indicates which event has occurred by turning the button on or off. 5.3 UPS Management Because different UPSs provide different functions, the UPS you have may not support the same configuration or control items. 5.3.1 Configure The configure page is designed to set the configurable values of the UPS or SNMP card. These values will be stored in the UPS or SNMP card. Note: Different UP
Résumé du contenu de la page N° 19
SNMP-NV6 5.3.1.1 Auto Restart Sends the command to the UPS to configure the auto restart function. 5.3.1.2 UPS Buzzer Sends the command to the UPS to configure the buzzer function. 5.3.1.3 Low Battery The set value is compared to the received value from the UPS. If the received battery level is lower than the assigned value then the card sends the Low Battery Warning. 5.3.1.4 UPS Shutdown Action The set value is compared to the received value from the UPS. If the Power Fail or Low B
Résumé du contenu de la page N° 20
SNMP-NV6 5.3.2 Control This menu allows you to send the control commands to the UPS. 5.3.2.1 Battery Test Sends the command to the UPS to perform a battery test. 5.3.2.2 Shutdown & Restart UPS Only Sends the command to the UPS to perform the Shutdown and/or Restart function. If you only want to shutdown the UPS mark the UPS Shutdown Delay check box and fill in the delay time. If you only want to restart the UPS mark the UPS Restart Delay check b