Résumé du contenu de la page N° 1
ETA-C15D
Power Conditioner
ETA-C15D
Power Conditioner
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 1 – ETAsys.com
Specifications are subject to change without notice.
Résumé du contenu de la page N° 2
ETA-C15D Power Conditioner TABLE OF CONTENTS Safety Instructions ...................................................................................................................................3 Introduction ..............................................................................................................................................5 Key Features ................................................................................................................................
Résumé du contenu de la page N° 3
ETA-C15D Power Conditioner SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an CAUTION equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the RISK OF ELECTRIC SHOCK product’s enclosure that may be of sufficient magnitude PA Amplifier DO NOT OPEN to constitute a risk of electric shock to persons. Model AA35 RISQUE DE DECHARGE ELECTRIQUE ´ ATTENTION -NE PAS OUVRIR. Output Rated 35W The exclamation point within an
Résumé du contenu de la page N° 4
ETA-C15D Power Conditioner CAUTION – WHEN INSTALLING THE PRODUCT • Plugging in or unplugging the power cord with wet hands may result in electric shock. • Never move the unit with the power cord plugged into the wall, as damage to the power cord may result. • When unplugging the cord from the wall, grasp the plug, NOT the cord. • Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where sooty smoke or steam are p
Résumé du contenu de la page N° 5
ETA-C15D Power Conditioner INTRODUCTION Thank you for purchasing the ETA Systems ETA-C15D AC Power Conditioner. The ETA-C15D has been designed to meet most installation requirements for AC power distribution and equipment power protection. The 15A compact 1RU unit AC Mains Voltage can be monitored via the front panel from the precision Digital Volt Meter. To light your rack, the ETA-C15D has incorporated a front panel pull-out dimmable LED tube light. The rear of the rack can be
Résumé du contenu de la page N° 6
ETA-C15D Power Conditioner KEY FEATURES • 10 T otal Outlets Are Provided • 8 Rear Panel Outlets • 2 Front Panel and 1 Rear Panel Unswitched Convenience Outlets • RFI Noise Filtering to Reduce Radio Frequency Interference • EMI T o Reduce Electromagnetic Interference • Dual Clamping Spike & Surge Suppression, DCS Circuitry • Front Panel Digital AC Mains V oltmeter • LED Indication of Reversed “Live” and “Neut
Résumé du contenu de la page N° 7
ETA-C15D Power Conditioner 8 9 10 11 12 6 7 6. AC Mains Function Display 7. AC Mains Voltage Display – This display will illuminate when the AC Mains power cord is plugged into an AC source. Note: the display has a 1.5% tolerance. 8. Power ON LED – Will illuminate green when the AC Mains Power Switch is in the ON Position. 9. AC Mains Wiring Polarity Fault Indicator – The Red LED will illuminate if the AC Mains Power Cord is plugged into an AC Mains
Résumé du contenu de la page N° 8
ETA-C15D Power Conditioner REAR PANEL FEATURES 6 5 2 3 4 1 1. AC Mains Input – Connect the 9' (3m) power cord to a 15A 120VAC outlet to provide power to the ETA-C15D. 2. AC Filtered Outlets – The six AC outlets are “Live” when the power switch is activated. These outlets are recommended for products such as Computers, Modems, Routers, DSP Processors, Cable/SAT, DVD, or CRT TVs. These outlets have a special filter circuit that is optimized to reduce interference to your Digit
Résumé du contenu de la page N° 9
ETA-C15D Power Conditioner TROUBLESHOOTING GUIDE Issue: Wiring Fault LED is illuminated. Possible Cause: AC Mains outlet is wired incorrectly. Action Needed: Contact a certified electrician to inspect the building's wiring. Issue: No power to the AC outlets. Possible Cause: Circuit breaker has tripped due to excessive load. Action Needed: Remove one piece of equipment from the ETA-C15D, and push the breaker reset tab located on the front panel. Note: We suggest fi
Résumé du contenu de la page N° 10
ETA-C15D Power Conditioner SPECIFICATIONS Type Power Conditioner & Suppressor Load Rating 15A FRONT PANEL Outlets 2 Unswitched Lights 1 Pull Out LED with Dimmer Switch Activation Switch Rocker Circuit Breaker 15A Resettable AC Mains Voltmeter Three Digits, Digital Indicators AC Power On, Abnormal Voltage, AC Fault, Breaker Open, Wiring Fault REAR PANEL AC Outlets 8 Outlets total, 6 Filtered, 1 High Power Non-Filtered, 1 Unswitched Connector LED Light Socket XLR Socket to pr
Résumé du contenu de la page N° 11
ETA-C15D Power Conditioner Notes 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 11 – ETAsys.com Specifications are subject to change without notice.
Résumé du contenu de la page N° 12
ETA-C15D Power Conditioner LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of one year. Additionally, fuses and lamps carry no warranty. ETA Systems will solely at its discretion, replace at no charge or repair free o