Résumé du contenu de la page N° 1
®
Powerware 9315 UPS
500–750 kVA
Installation and Operation Manual
Résumé du contenu de la page N° 2
IMPORTANTSAFETYINSTRUCTIONS SAVETHESEINSTRUCTIONS Thismanualcontainsimportantinstructionsthatyoushouldfollowduringinstallationandmaintenanceof theUPSandbatteries.Pleasereadallinstructionsbeforeoperatingtheequipmentandsavethismanualfor futurereference. CONSIGNESDESÉCURITÉIMPORTANTES CONSERVERCESINSTRUCTIONS Cemanuelcomportedesinstructionsimportantesquevousêtesinvitéàsuivrelorsdetouteprocédure d’installationetdemaintenancedesbatteriesetdel’onduleur.Veuillezconsulterentièrementces instructionsavant
Résumé du contenu de la page N° 3
SpecialSymbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISKOFELECTRICSHOCK-Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFERTOOPERATOR’SMANUAL -Refer to your operator’s manual for additional information, such as important operating and maintenance instructions. This symbol indicates that you should not discard the UPS or the UPS batteries in the trash. This product c
Résumé du contenu de la page N° 4
This page intentionally left blank.
Résumé du contenu de la page N° 5
Table of Contents 1 Introduction ........................................................................... 1-1 1.1 UPSFeatures ......................................................................................... 1-2 1.1.1 InstallationFeatures ............................................................................... 1-2 1.1.2 CustomerInterface ................................................................................ 1-2 1.1.3 CustomerConvenienceOutlet..........................
Résumé du contenu de la page N° 6
TABLE OF CONTENTS 6 InstallingOptionalAccessories ........................................................... 6-1 6.1 InstallinganRMP ...................................................................................... 6-2 6.2 InstallinganRIM ...................................................................................... 6-5 6.3 InstallinganSCM ...................................................................................... 6-7 6.4 InstallingX-SlotCards............................
Résumé du contenu de la page N° 7
TABLE OF CONTENTS 11 RespondingtoSystemEvents ............................................................. 11-1 11.1 SystemEventHorns .................................................................................... 11-1 11.2 SystemEventIndicators ................................................................................. 11-1 11.3 SystemEventMessages ................................................................................. 11-1 12 Communication ................................
Résumé du contenu de la page N° 8
TABLE OF CONTENTS 14 ProductSpecifications .................................................................. 14-1 14.1 ModelNumbers ....................................................................................... 14-1 14.2 UPSSystemInput ...................................................................................... 14-1 14.3 UPSSystemOutput..................................................................................... 14-2 14.4 EnvironmentalSpecifications...................
Résumé du contenu de la page N° 9
List of Figures Figure1-1.TypicalPowerware9315(500–750kVA)UPSSystem .................................................. 1-1 Figure2-1.CabinetasShippedwithOuterPackagingandPallet................................................... 2-2 Figure4-1.RemoteBatteryDisconnectEnclosure ............................................................. 4-1 Figure5-1.RemoteEmergencyPower-off(REPO)Control ........................................................ 5-1 Figure5-2.REPOWiring .............................
Résumé du contenu de la page N° 10
LIST OF FIGURES FigureA-10.SecuringCables ........................................................................... A-18 FigureA-11.CB2TBtoDCSourceDisconnectDevice........................................................... A-21 FigureA-12.Inverter/RectifierCabinet–PCM1Terminals....................................................... A-22 FigureA-13.Inverter/RectifierCabinet–PCM1Terminals(continued) .............................................. A-23 FigureA-14.Output/InverterCabinet–PCM2Termina
Résumé du contenu de la page N° 11
Chapter 1 Figure1Table1 Introduction ® ® The Eaton Powerware 9315 (500–750 kVA) uninterruptible power supply (UPS) is an online power protection system that prevents loss of valuable electronic information, minimizes equipment downtime, and minimizes the adverse effect on equipment production because of unexpected power problems. The Powerware 9315 UPS system continually monitors incoming electrical power and removes the surges, spikes, sags, and other irregularities that are inherent in commerc
Résumé du contenu de la page N° 12
INTRODUCTION 1.1 UPS Features The UPS has many standard features that provide cost-effective and consistently reliable power protection. The descriptions in this section provide a brief overview of the UPS standard features. 1.1.1 Installation Features Power wiring can be routed through the top of each cabinet. External sensing and monitoring control wire must be installed according to UL Class I requirements. Class I wiring can be routed through the top of each cabinet. 1.1.2 Customer Interface
Résumé du contenu de la page N° 13
INTRODUCTION 1.2 Options and Accessories Contact your Eaton sales representative for information about the following options: 1.2.1 5% Input Filter The UPS can be equipped with an input filter. An input filter yields power factor correction that allows you to save on your initial installation and operating costs. The filter also reduces input harmonic current distortion and minimizes upstream interference that can damage sensitive hardware components. 1.2.2 Battery Racks You can enhance the prot
Résumé du contenu de la page N° 14
INTRODUCTION 1.2.6 Monitoring and Communication The following monitoring and communication options are available: S RemoteMonitorPanel(RMP) – An optional RMP contains backlit status indicators and a local horn, allowing you to monitor the UPS operational status and alarm condition from virtually any location within your facility. This option is described further in Chapter 10, “Using Features and Options.” S RelayInterfaceModule(RIM) – An optional RIM uses relay contact closures to indicate the
Résumé du contenu de la page N° 15
INTRODUCTION 1.4 Safety Warnings IMPORTANTSAFETYINSTRUCTIONS SAVETHESEINSTRUCTIONS S Thismanualcontainsimportantinstructionsthatshouldbefollowedduringinstallationandmaintenance oftheUPSandbatteries.Pleasereadallinstructionsbeforeoperatingtheequipmentandsavethis manualforfuturereference. S TheUPScabinetisdesignedforindustrialorcomputerroomapplicationsandcontainssafetyshields behindthefrontdoors.However,theUPSsystemisasophisticatedpowersystemandshouldbehandled withappropriatecare. DANGER ThisUPSco
Résumé du contenu de la page N° 16
INTRODUCTION AVERTISSEMENT! S Lesbatteriespeuventprésenterunrisquededéchargeélectriqueoudebrûlurepardescourts-circuitsde hauteintensité.Prendrelesprécautionsnécessaires. S Pourleremplacement,utiliserlemêmenombreetmodéledesbatteries. ATTENTION! S Unemiseaurebutréglementairedesbatteriesestobligatoire.Consulterlesrèglementsenvigueurdans votrelocalité. S Nejamaisjeterlesbatteriesaufeu.L’expositionauxflammesrisquedelesfaireexploser. 1.5 Conventions Used in This Manual This manual uses these type conv
Résumé du contenu de la page N° 17
INTRODUCTION 1.7 Getting Help If you need help with any of the following: S Scheduling initial startup S Regional locations and telephone numbers S A question about any of the information in this manual S A question this manual does not answer Please call the Eaton Help Desk for Powerware products at: United States: 1-800-843-9433 or1-919-870-3028 Canada: 1-800-461-9166 ext 260 All other countries: Call your local service representative ® EATON Powerware 9315 UPS (500–750 kVA) Installation and O
Résumé du contenu de la page N° 18
INTRODUCTION This page intentionally left blank. ® 1-8 EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com
Résumé du contenu de la page N° 19
Section I Installation ® EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com 1-1
Résumé du contenu de la page N° 20
® 1-2 EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com